• 제목/요약/키워드: Flow-supply Characteristics

검색결과 449건 처리시간 0.027초

호흡기 감염 격리병원의 물류시스템 계획에 관한 연구 (A Study on the Architectural Planning of Material Handling System for the Airborne Infection Isolation Hospitals)

  • 최광석;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.63-72
    • /
    • 2017
  • Purpose: The purpose of this study is to review the material handling system of the Airborne Infection Isolation Hospitals which is the one of the key elements of infection control and to improve the basic data for the planning and design of those facilities. Methods: Research was conducted by literature reviews and case studies for the material handling system of domestic and foreign Isolation hospitals. Results: The result of this study can be summarized into three points. First, a general isolation unit and a high level isolated unit need to be distinguished in terms of efficiency and safety. In particular, it is desirable that a high level isolated unit have to completely separate clean and soiled circulations, and soiled corridor should be installed by those means. By doing this, the medical staff can observe patient rooms and supply clean materials directly in the clean zone without wearing PPE, so that safety and work efficiency can be improved at the same time. Second, for the safe disposal of wastes, it is desirable to install a dedicated sterilizer per ward and sterilize it at least in the ward. In addition, It is desirable to install a central waste treatment room and a dedicated soiled corridor in consideration of the inadequate handling capacity and emergency situation. Third, the characteristics of material flow chart in the negative pressured isolation hospitals and the corresponding material handling system have been presented. Implications: Infection control is very important in safety, but it is necessary to respond to the symptoms of the patient.

화염중 발생하는 SiO$_2$/TiO$_2$/다성분입자의 조성특성에 관한 실험적 연구 (An Experimental Study on Composition Characteristics of SiO$_2$/TiO$_2$/Multicomponent Particle Generated in a Coflow Diffusion Flame)

  • 김태오;서정수;최만수
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1175-1182
    • /
    • 2001
  • Chemical compositions of polydisperse SiO$_2$/TiO$_2$multicomponent aggregates were measured for different heights from the burner surface and different mobility diameters of aggregates. SiO$_2$/TiO$_2$multicomponent particles were generated in a hydrogen/oxygen coflow diffusion flame from two sets of precursors: TTIP(titanium tetraisopropoxide), TEOS(tetraethylorthosilicate). To maintain 1:1 mole ratio of TTIP:TEOS vapor, flow rate of carrier gas $N_2$was fixed at 0.6lpm for TTIP, at 0.1lpm for TEOS. In-situ sampling probe was used to supply particles into DMA(differential mobility analyzer) which was calibrated with using commercial DMA(TSI, model 3071A) and classifying monodisperse multicomponent particles. Classified monodisperse particles were collected with electrophoretic collector. The distributions of composition from particles to particle were determined using EDS(energy dispersive spectrometry) coupled with TEM(transmission electron microscope). The chemical(atomic) compositions of classified monodisperse particle were obtained for different heights; z=40mm, 60mm, 80mm. The results suggested that the chemical(atomic) composition of SiO$_2$decreased with the height from burner surface and the composition of SiO$_2$and TiO$_2$approached to the value of 1 to 1 fat downstream. It is also found that the composition of SiO$_2$decreases as the mobility diameter of aggregate increases.

화염중 발생하는 $SiO_2/TiO_2$ 다성분입자의 조성특성에 관한 실험적 연구 (An Experimental Study on Composition Characteristics of $SiO_2/TiO_2$ Multicomponent Particle in Coflow Diffusion Flame)

  • 김태오;서정수;최만수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.441-446
    • /
    • 2000
  • Chemical compositions of monodisperse $SiO_2/TiO_2$ multicomponent aggregates were measured for different heights from the burner surface and different mobility diameters of aggregates. $SiO_2/TiO_2$ multicomponent particles were generated in a hydrogen/oxygen coflow diffusion flame from two sets of precursors: TTIP (titanium tetraisopropoxide), TEOS(tetraethylorthosilicate). To maintain 1:1 mole ratio of TTIP:TEOS vapor theoretically, flow rate of carrier gas $N_2$ was fixed at 0.61pm for TTIP, at 0.11pm for TEOS. In situ sampling probe was used to supply particles into differential mobility analyzer(DMA) which was calibrated with using commercial DMA(TSI 3071A) and classifying monodisperse multicomponent particles. Classified particles were collected with electrophoretic collector. The distributions of composition from particle to particle were determined using EDS (energy dispersive spectrometry) coupled with TEM (transmission electron microscope). The chemical (atomic) compositions of classified monodisperse particle were obtained for different heights; z=40mm, 60mm, 80mm. The results suggested that the atomic composition of $SiO_2$ decreased with the height from burner surface and the composition of $SiO_2$ and $TiO_2$ approached to the value of 1 to 1 in far downstream. It is also found that the composition of $SiO_2$ decreases as the mobility diameter of aggregate increases.

  • PDF

히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구 (Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation)

  • 백영진;김민성;장기창;이영수;김현주
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.797-802
    • /
    • 2012
  • 본 연구에서는 두 대의 히트펌프를 이용하여 $60^{\circ}C$의 난방 공급을 하는 경우에 대하여, 병렬운전을 할 경우의 성능과 직렬운전을 할 경우의 성능을 서로 비교함으로써, 직렬운전에 의한 성능 향상 가능성을 연구하였다. 두 경우의 성능을 공정하게 비교하기 위하여, 히트펌프를 구성하는 열교환기의 전열면적을 고정하였으며, 부하측 및 열원측의 입구 유량 및 온도 조건을 고정하였다. 또한, 보다 현실적인 결과를 위하여 열교환기 내 열전달 및 압력강하 특성을 고려하였다. 시뮬레이션 결과, 직렬운전 시스템의 난방성능계수가 병렬운전 시스템의 난방성능계수에 비해 본 연구의 시뮬레이션 조건 하에서 약 5% 향상 될 수 있음을 관찰하였다.

대단면국내석회석광산용저풍압국부선풍기개발연구 (Development of a Low Pressure Auxiliary Fan for Local Large-opening Limestone Mines)

  • 이창우;웅웬반득
    • 터널과지하공간
    • /
    • 제25권6호
    • /
    • pp.543-555
    • /
    • 2015
  • 최근 대단면 갱도로 개발하고 있는 국내 석회석광산은 작업공간 환기를 위하여 과거 석탄광산에 광범위하게 사용되던 형태의 국부 선풍기를 주로 이용하고 있다. 대단면 갱도에서의 낮은 정압손실을 고려할 때 고풍압 선풍기는 과다 설비용량으로 인하여 비용측면에서 심각한 한계를 보이고 있다. 대단면 갱도에서의 최적 선풍기는 안전한 작업환경 유지를 위한 충분한 환기량을 공급할 수 있어야 할 뿐만 아니라 저운전비용도 보장하여야 한다. 본 연구는 대단면 갱도 내에서 높은 환기효율과 경제성을 가지는 저풍압 국부선풍기를 개발함이 목적이다. 이론적 연구와 아울러 2개소의 단면적이 다른 현장 실험 연구를 통하여 저풍압 선풍기의 환기효율을 분석하였다. 본 연구결과는 작업공간 공기질 및 작업환경 개선을 위한 국부선풍기의 경제성과 효율 제고에 적용 가능할 것으로 기대된다.

하이브리드 로켓의 HTPB의 연소특성에 관한 연구 (A Study on Combustion Characteristic of HTPB in Hybrid Rocket)

  • 이정표;조성봉;김수종;김진곤;문희장;성홍계;최성한;장기원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.203-207
    • /
    • 2007
  • 하이브리드 추진 시스템에서의 HTPB 연료의 연소특성에 관한 연구를 수행하였다. 본 실험에서는 연료는 HTPB, 산화제는 GOX를 사용하였다. 산화제의 유량은 직경이 다른 여러개의 쵸킹 오리피스로 제어했고, 산화제 공급 유량범위는 $13.8{\sim}42.7g/sec$ 이었다. 본 실험의 HTPB 결과와 외국의 연구 결과를 비교하였으며, PE와의 연소성능을 비교 분석하였다. 하이브리드 추진 시스템의 고체연료로서 HTPB가 PE보다 연소율 및 효율이 높음을 확인하였다.

  • PDF

기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성 (Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System)

  • 김동석;박영식
    • 한국물환경학회지
    • /
    • 제30권4호
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

토지이용 특성에 어울리는 완충식생 활용 계획 (A Plan for Utilizing the Buffering Vegetation based on the Land use Type)

  • 안지홍;임치홍;임윤경;남경배;피정훈;이창석
    • 한국물환경학회지
    • /
    • 제32권5호
    • /
    • pp.465-474
    • /
    • 2016
  • Since Gyungan stream is included in the protected zone of the water supply source of the Metropolitan area in Korea, the water quality needs to be continuously managed. Therefore, a measure is required that can inhibit the flow of water pollutant into the water body and facilitate the ecological restoration of riparian vegetation. A field survey was conducted on the hydrological characteristics of the landscape elements established on the downstream catchment of the Gyungan stream, the result of which showed that the paddy field and urbanized area can be regarded as point pollution sources. The upland field can be regarded as a non-point pollution source. In order to improve the water quality in the Paldang lake, we first recommended creating a riparian vegetation belt. We also suggested introducing a treatment wetland and an artificial plant island to places in which the creation of a riparian vegetation belt is not ensured. We recommend creating a treatment wetland equipped with diverse functional groups. For creating the plant island, we recommend Zizania latifolia and Typha orientalis, which showed the highest productivity among aquatic plants. The former could be introduced around the outlet of a paddy field and the estuary of tributaries, while the latter could be introduced to a water body directly sourced from mountainous land.

낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle)

  • 김철주;강환국;김윤철
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

각 부하지점별 유효부하지속곡선 작성법에 관한 연구 (A Study on Construction of the CMELDC at Load Points)

  • 김홍식;문승필;최재석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.195-198
    • /
    • 2000
  • This paper illustrates a new method for constructing composite power system effective load duration curve(CMELDC) at load points. The main concept of proposed method is that the CMELDC can be obtain from convolution integral processing of the outage probabilistic distribution function of not supplied power and the load duration curve given at each load point. The effective load duration curve (ELDC) at HLI plays an important part in probabilistic production simulation, reliability evaluation, outage cost assessment and power supply margins assesment for power system planning and operation. And also, the CMELDC at HLII will extend the application areas of outage cost assessment and reliability evaluation at each load point. The CMELDC at load points using the Monte Carlo method and a DC load flow constrained LP have already been developed by authors. The effective load concept at HLII, however, has not been introduced sufficiently in last paper although the concept is important. In this paper, the main concept of the effective load at HLII which is proposed in this study is defined in details as the summation of the original load and the probabilistic loads caused by the forced outage of generators and transmission lines at this load point. The outage capacity probabilistic distribution function at HLII can be obtained by combining the not supplied powers and the probabilities of the not supplied powers at this load point. It si also expected that the proposed CMELDC can be applied usefully to research areas such as reliability evaluation, probabilistic production cost simulation and analytical outage cost assessment, etc. at HLII in future. The characteristics and effectiveness of this methodology are illustrated by case study of IEEE-RTS.

  • PDF