• Title/Summary/Keyword: Flow-rate measurement

Search Result 909, Processing Time 0.027 seconds

An approach for the functional extension of the remote measurement method of unsteady flow rate

  • Yokota, Shin-ichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.235-239
    • /
    • 1992
  • The paper describes an approach for estimating unsteady flow rate through oil hydraulic pipelines and components in real time. Recently we have proposed following three unsteady flow rate measurement approaches; RIFM, QIFM and TPFM, in which hydraulic pipeline dynamics are made use of. In this paper, we firstly propose new approaches, i.e, an interpolation and an extrapolation methods in combination with RIFM and TPFM. In the interpolation method, unsteady flow rate at the arbitrary internal location along the pipeline between two points for measuring the two point pressure can be estimated. In this paper, the accuracy and dynamic response of interpolation method are mainly experimentally investigated in detail.

  • PDF

Comparison of Ultrasonic Paths for Flow Rate Measurement (유량측정을 위한 초음파 전파경로 비교)

  • Kim, Ju Wan;Piao, Chunguang;Kim, Jin Oh;Park, Doo-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.7
    • /
    • pp.455-461
    • /
    • 2015
  • The paper deals with the accuracy comparison between two kinds of ultrasonic paths for flow rate measurement. In the Z-path, two transducers are installed on the opposite sides of each other on a pipe, and the ultrasonic waves generated at one transducer propagate to arrive at the other one only by refraction. In the V-path, two transducers are installed on one side of a pipe, and the ultrasonic waves reflected at the inner wall of the pipe are received. Transit times were confirmed to identify the propagation paths by comparing the theoretically calculated results and measured ones. The flow rate measurements with two kinds of ultrasonic paths appeared very similar. It would be possible to select either of the paths by considering the advantages and disadvantages.

A Study on the Development of Measurement System for Fluid Volume and Flow Rate (유체의 유량 및 유속 측정 시스템 개발에 관한 연구)

  • Lee, Seok-Won;Lee, Tea-Jin;Nam, Yun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2492-2494
    • /
    • 2003
  • Urine analysis is one of the most important medical examination in the hospital. Not only the data for the ingredients of urine through chemical analysis, but also the data related to fluid dynamics, e.g., peak flow rate, average flow rate, may provide some useful information about patient's state of health. Therefore, we develop the portable system to measure and analyse fluid volume/flow rate in this study. This system can store and print the measured data during the pre-specified time interval, and provide some meaningful data related with fluid dynamics. We explain the method and the technical stuff to implement the system, and show the result.

  • PDF

On Apparent Density and Flow Rate Measurement at Elevated Temperature for Powder Mixes Intended for Warm Compacting (온간성형용 분말의 고온 유동도와 겉보기 밀도 측정에 관하여)

  • Lee Jeong-Keun;Kim Soon-Wook
    • Journal of Powder Materials
    • /
    • v.13 no.1 s.54
    • /
    • pp.52-56
    • /
    • 2006
  • The aim of this work was to establish an optimal condition for determination of apparent density and flow rate for warm compacting powder. For this purpose it was evaluated uncertainty on them according to ISO Guide to the Expression of Uncertainty in Measurement. This evaluation example would be useful even in powder fluidity measurement at room temperature.

Fabrication of a Micro Magnetic Flowmeter for Micro Flow Rate Measurement (미소 유량 측정을 위한 마이크로 전 유량계의 제작)

  • Yoon, Hyeun-Joong;Kim, Geun-Young;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3268-3270
    • /
    • 1999
  • This paper presents the fabrication of a micro electromagnetic flowmeter for liquid flow rate measurement. The flowmeter consists of a silicon flow channel with two electrodes and two permanent magnets. The micro flow channel and the detection electrodes are fabricated by the anisotropic etching of two silicon substrates and the metal evaporation process respectively. If conductive fluid passes through a magnet field, electromotive force is generated and detected by two electrodes. When the flow rate is 2.6 ml/sec, the measured output voltage is 7.4 mV.

  • PDF

A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field (현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교)

  • An, Seung-Hee;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

A study on the dynamics of a turbine-meter-type flowmeter for hydraulic systems

  • Yokota, Shinichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.60-65
    • /
    • 1994
  • In this study, the dynamic characteristics of a turbine-meter-type flowmeter is investigated by making use of the remote instantaneous flow rate measurement method (RIFM). The results of the frequency response test indicated that the gain of the flow rate of the turbine-meter-type flowmeter relative to the flow rate of the RIFM was nearly unity up to 40Hz and the phase lag of the flow rate became 90 degrees at 70Hz.

  • PDF

Performance Evaluation of the Velocity Profile Integration for the Multi-Path Ultrasonic Flowmeter in Symmetric & Asymmetric Flow Field (대칭 및 비대칭 유동장에서 다회선 초음파 유량계의 유속분포 적분 방법 평가)

  • Kim, Joo-Young;Kim, Kyung-Jin;Park, Sung-Ha
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.370-377
    • /
    • 2002
  • Generally, the system of calculation for the multi-path ultrasonic flow meters can be divided into two methods by how to get the mean velocity, namely, weighting and direct method. Weighting-method derive the mean velocity through modeling in theoretical velocity profile. Direct-method derive the mean velocity though actual flow distribution. The system of calculation varies with maker's transducer configuration and integration method. Each system has merits and demerits. This paper describes the system of integration that calculates line velocity over cross-section of the circular pipe. Flow rate mr discussed in this paper is a difference between theoretical flow rate and integrated flow rate according to values of Reynolds number in symmetric flow field or theoretical flow rate and integrated flow rate according to rotated model in asymmetric flow field.

  • PDF

Investigating Wastewater Flow Characteristics - O and M Treatment Basins of A City - (처리분구별 하수발생 특성 조사 - A시 O, M 처리분구 -)

  • Hwang, Byung-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.348-356
    • /
    • 2005
  • Water quality sampling surveys and continuous measurement of flow were conducted to identify wastewater flow characteristics for representative catchment of O and M treatment basins in A city. For HS-1 station representing commercial area, wastewater flow rises in the beginning of office-working hours, moves up and down within narrow range, and lasts till office-leaving hour, and falls gradually reflecting worker's returning home. However, in HS-2 station representing residential area, wastewater flow has two peaks, which are before office-going hour and after office-leaving hour. In residential area, the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period. To determine the priority for rehabilitation of sewer system, infiltration rate was computed by dividing infiltration flow by mean diameter and total length of sewer, and HS-1 station ranked the first.

A Study on Applicability of Ultrasonic Flowmeter to Feedwater Flow Measurements in Nuclear Power Plants (원자력발전소의 급수유량 측정에 대한 초음파유량계의 적용성 연구)

  • Yu Sung-Sik;Park Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.57-65
    • /
    • 2003
  • The measurement uncertainties of an ultrasonic flowmeter were analyzed to evaluate its applicability to the measurement of the steam generator feedwater flow-rate in a nuclear power plant. The analyses of measurement uncertainties of a reactor power were also performed with the analyses of feedwater flow measurement uncertainties. Two ultrasonic flowmeters based on a cross-correlation technique and a transit time method were used in this study. The ultrasonic flowmeters were installed on a feedwater pipe line of a typical 1000 MWe Korea-standardized nuclear power plant to take the necessary data. The results have shown that the measurement uncertainties of the ultrasonic flowmeters are adequately smaller than those or a venturi meter. The research has also indicated that the measurement uncertainties of the reactor power based on the ultrasonic flowmeter uncertainties are sufficiently bounded by the uncertainty range usually assumed in nuclear safety analyses.