• 제목/요약/키워드: Flow-rate error

검색결과 362건 처리시간 0.023초

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

MR PC 영상을 이용한 유체 흐름 분석 (Measurement of Flow Velocity and Flow Visualization with MR PC Image)

  • 김수정;이동혁;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

엔트로피 개념을 이용한 제주도 상시하천의 평균유속분포 추정 (Mean Velocity Distribution of Natural Stream using Entropy Concept in Jeju)

  • 양세창;양성기;김용석
    • 한국환경과학회지
    • /
    • 제28권6호
    • /
    • pp.535-544
    • /
    • 2019
  • We computed parameters that affect velocity distribution by applying Chiu's two-dimensional velocity distribution equation based on the theory of entropy probability and acoustic doppler current profiler (ADCP) of Jungmun-stream, Akgeun-stream, and Yeonoe-stream among the nine streams in Jeju Province between July 2011 and June 2015. In addition, velocity and flow were calculated using a surface image velocimeter to evaluate the parameters estimated in the velocity observation section of the streams. The mean error rate of flow based on ADCP velocity data was 16.01% with flow calculated using the conventional depth-averaged velocity conversion factor (0.85), 6.02% with flow calculated using the surface velocity and mean velocity regression factor, and 4.58% with flow calculated using Chiu's two-dimensional velocity distribution equation. If surface velocity by a non-contact velocimeter is calculated as mean velocity, the error rate increases for large streams in the inland areas of Korea. Therefore, flow can be calculated precisely by utilizing the velocity distribution equation that accounts for stream flow characteristics and velocity distribution, instead of the conventional depth-averaged conversion factor (0.85).

압력섭동에 의한 유량변동 측정 정량화 (Quantifying the Variation of Mass Flow Rate generated by Pressure Fluctuation)

  • 길태옥;김동준;조성호;안규복;한영민;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.152-156
    • /
    • 2007
  • 로켓 엔진에서 연소챔버 내의 압력섭동에 의해 발생되는 추진제 유량변동에 대한 현상을 파악하는 것은 매우 중요하다. 이를 위해 압력섭동이 발생되었을 때 유량변동의 측정에 대한 정량화를 수행하였다. 오리피스 내의 유동의 속도를 알기 위해 오리피스 내의 압력을 측정한 후 이론식에 입각하여 속도를 풀었고, 액막두에 측정장치를 이용하여 오리피스 내에서의 면적을 측정하였다. 정상상태에서의 속도 및 유량을 분석값과 비교한 결과, 매우 작은 오차내에서 일치함을 알 수 있었다. 따라서, 본 연구에서 도출된 이론식을 바탕으로 비정상상태에서의 유량 변동 측정을 수행하는데 큰 역할을 할 수 있을 것이다.

  • PDF

Quantifying the Variation of Mass Flow Rate generated in a Simplex Swirl Injector by the Pressure Fluctuation for Injector Dynamics Research

  • Khil, Tae-Ock;Kim, Sung-Hyuk;Cho, Seong-Ho;Yoon, Young-Bin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.218-225
    • /
    • 2008
  • When the heat release and acoustic pressure fluctuations are generated in the combustor by irregular combustion, these fluctuations affect the mass flow rate of the propellants injected through the injectors. Also, the variations of the mass flow rate by these fluctuations again bring about irregular combustion and furthermore that is related with combustion instability. Therefore, it is very important to identify the mass variation for the pressure fluctuation on the injector and to investigate its transfer function. So, we first have studied quantifying the variation of mass flow rate generated in simplex swirl injector by injection pressure fluctuation. To acquire the transient mass flow rate in orifice with time, we have tried to measure of the flow axial velocity and liquid film thickness in orifice. The axial velocity is acquired through theoretical approach after measuring the pressure in orifice and the flow area in the orifice is measured by electric conductance method. As results, mass flow rate calculated by axial velocity and liquid film thickness measuring in orifice accorded with mass flow rate acquired by direct measuring method in the small error range within 1 percents in steady state and within 6 percents as average mass flow rate in pulsated state. Hence this method can be used to measure the mass flow rate not only in steady state but also in unsteady state because the mass flow rate in the orifice can acquire with time and this method shows very high accuracy based on the experimental results.

  • PDF

하상재료에 따른 ADCP의 유량측정 비교 분석 (Comparative Analysis of ADCP Flow Measurement According to River Bed Material)

  • 최진우;홍창수;신경용;이진욱;김정애;조용철;유순주
    • Ecology and Resilient Infrastructure
    • /
    • 제5권3호
    • /
    • pp.156-162
    • /
    • 2018
  • 본 연구는 하상재료에 따른 ADCP의 측정 적합성을 평가하기 위해 하상 재료가 다른 자갈 하상과 모래 하상인 지점에서 ADCP의 유속, 수심 및 유량 자료를 ADV의 측정 결과와 비교 분석하였다. 연구결과 자갈 하상과 모래 하상에서의 ADV와 ADCP를 이용한 유속 분포와 수심 측정 자료는 비슷하게 나타났다. 유량측정 결과 자갈 하상에서 평균 3.5 - 4.8%, 모래 하상에서 평균 0.02 - 3.2%의 상대오차 범위를 나타내어 USGS에서 제시한 평균 오차 5%의 범위보다 작아 신뢰가 높은 결과인 것을 알 수 있었다. 이한 결과는 향후 ADCP의 하천 적용성에 대한 기초자료로 활용될 수 있으며 ADCP의 불확도 평가에 중요한 자료로 이용될 것으로 판단된다.

ATM망을 위한 실시간 트래픽 제어 기법:RCT (A Real-time Traffic Control Scheme for ATM network:RCT)

  • 이준연;이재완;권혁인
    • 한국정보처리학회논문지
    • /
    • 제4권11호
    • /
    • pp.2822-2831
    • /
    • 1997
  • ATM을 기반으로 하는 B-ISDN 망은 다양한 트래픽 특성과 서비스 요구사항을 가진 여러가지 종류의 서비스를 지원해야한다. ATM 계층에는 link 계층간의 흐름 제어나 에러 제어가 없다. 그러나 다양한 종류의 각종 서비스를 위해 각기 다른 다른 흐름/에러 제어 기법이 AAL 계층이나 상위 계층(예를 들어 OSI 7 계층의 4번 전송 계층)에서 수행될 수 있다. 전통적인 데이타망에서는 에러 제어 기법이 결합된 윈도우 흐름 제어 기법이 널리 사용되었다. 그러나 윈도우 흐름 제어 기법은 전파 전달 지연(Propagation delay)이 전송률(Transmission rate)에 비해 상대적으로 너무 크기 때문에 ATM 망에서 유용하지 않을 수 있다. 본 논문에서는 양단간(end-to-end) 자료 전송을 위한 매우 간단한 흐름제어 기법인 RCT (Rate Control for end-to-end Transport)를 제안한다. RCT는 평균 과부하(Overload) 기간의 분포가 특정 시간대에 편중되어 있을 때에 높은 성능을 보인다.

  • PDF

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF