• 제목/요약/키워드: Flow rates

검색결과 2,685건 처리시간 0.029초

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF

인산형 연료전지 발전성능에 미치는 반응기체 공급량 및 공급중단의 영향 (Effects of Reactant Gas Flow Rates and Starvation on Phosphoric Acid Fuel Cell Performance)

  • 송락현;김창수;최병우;최수현;신동렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.662-665
    • /
    • 1992
  • Effects of reactant gas flow rates and starvation on phosphoric acid fuel cell performance were studied. As the reactant gas flow rates increased, the cell performance increased and then the cell maintained constant performance. The optimum flow rates of hydrogen, oxygen and air under galvanostatic condition of 150 mA/$\textrm{cm}^2$ are found to be 3cc/min${\cdot}\textrm{cm}^2$, 4cc/min${\cdot}\textrm{cm}^2$, and 15cc/min${\cdot}\textrm{cm}^2$, respectively. Hydrogen and oxygen starvation resulted in voltage loss of about 5mV and 0-2mV, respectively. The voltage loss was independent of starvation time. These results were discussed from the point of view of electrochemical reaction of the cell.

  • PDF

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

습식클러치 마찰재의 체결 거동에 의한 마찰열 해석 (Frictional Heat Generation in Wet Clutch Engagement according to Groove Pattern on Clutch Pad)

  • 김해용;장시열;김우정
    • Tribology and Lubricants
    • /
    • 제30권5호
    • /
    • pp.265-270
    • /
    • 2014
  • Frictional heat greatly influences the friction behaviors during clutch engagement. Therefore, the engagement of a wet or dry clutch is frequently not under control by the frictional heat. In a wet clutch, the frictional temperature also specially needs to be controlled, and in many cases, the clutch material is selected to prevent a temperature rise from the friction between friction pad and separator. However, only the selection of the clutch material cannot ensure sufficient control of the temperature rise by the friction. The groove pattern on a friction pad is designed for more flow rates of transmission fluid between the contact gap of clutch pad and separator for the cooling effect. In this work, grove patterns are designed for more flow rates out of the contact gap between friction pad and separator plate. Selected groove design shows the improvement flow rates of transmission fluid through both inner and outer radius, where most of the transmission fluid flows through the outer radius when the clutch is engaged due to the centrifugal force in conventional wet clutch groove. Several comparisons of the amounts of frictional heat generated on clutch pads are made in order to verify the decrease of the temperature rise according to the flow rates along the groove patterns.

에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석 (Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption)

  • 한방우;강지수;김학준;김용진;원효식
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

데칸터를 이용한 텍서스속 식물세포 회수 (The Use of a Decanter for Harvesting Biomass rom plant Cell Cultures)

  • 김진현
    • KSBB Journal
    • /
    • 제15권4호
    • /
    • pp.337-341
    • /
    • 2000
  • The decanter is very useful to harvest biomass from plant cell cultures in large-scale process. It is very important to obtain high yield and low moisture content in recovered biomass so as to minimize solvent usage in subsequent extraction steps. Effluent clarity was also affected by the differential speed although this affect was more dramatic at higher flow rates than at lower flow rates. Moisure content was largely unaffected by flow rate. A decrease in moisture content was evident as differential speed decreased.

  • PDF

다공성 실리콘막을 포함한 전기침투 방식 펌프에서의 비대칭적 인 유동 (Asymmetric Flows for Porous Silicon Electroosmotic Pumps)

  • 김대중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.703-704
    • /
    • 2008
  • We fabricated and tested porous silicon-based electroosmotic pumps. Compared to other pumping media, porous silicon is beneficial for obtaining comparable flow rates with much lowered electric potential, while maintaining enough mechanical properties. We fabricated porous silicon with two sided-reactive etching processes. We found higher flow rate per electric potential (consistent with previous studies) and we also found asymmetric flow rates for different pumping directions. We plan to utilize this asymmetry for AC pumping applications.

  • PDF

터보펌프 인듀서의 내부 유동 해석 (An Interal Flow Analysis of Turbo Pump Inducer)

  • 심창열;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.631-636
    • /
    • 2001
  • The internal flow in the rocket pump inducer of LE-7 engine for H-II rocket was predicted at design and off-design flow rates using CFD code, CFX- Tascflow. In this numerical study, the performance curve of inducer coressponding to flow rates variation and the internal flow in the front of blade leading edge show good agreement between the calculations and the measurements. Backflow is appeared at suction side of leadinge edge tip, and this region is extended to upstream as flowrate decrease. Because of backflow, pressure loss coressponding to meridinal coordinate occupy 50% from inlet domain to leading edge. By this phenomena, pressure loss in front of blade leading edge take a great effect to inducer performance.

  • PDF

Analysis of newly designed CDI cells by CFD and its performance comparison

  • Kwon, Se Hwan;Rhim, Ji Won
    • Membrane and Water Treatment
    • /
    • 제7권2호
    • /
    • pp.115-126
    • /
    • 2016
  • In this study, computational fluid dynamics (CFD) analysis was conducted to investigate the flow pattern and to find the occurrence of dead zones in an existing capacitive deionization (CDI) cell. Newly designed cells-specifically designed to avoid dead zones-were analyzed by CFD in accordance with the flow rates of 15, 25 and 35 ml/min. Next, the separation performances between the existing and newly designed cell were compared by conducting CDI experiments in terms of salt removal efficiency at the same flow rates. Then, the computational and experimental results were compared to each other. The salt removal efficiencies of the hexagon flow channel 1 (HFC1) and hexagon flow channel 2 (HFC2) were increased 88-124% at 15 ml/min and 49-50% at 25 ml/min, respectively. There was no difference between the existing cell and the foursquare flow cell (FFC) at 35 ml/min.

Flow and Pressure Drop Characteristics of R22 in Adiabatic Capillary Tubes

  • Kim, Min-Soo;Kim, Sung-Goo;Ro, Sung-Tack
    • Journal of Mechanical Science and Technology
    • /
    • 제15권9호
    • /
    • pp.1328-1338
    • /
    • 2001
  • The objective of this study is to present flow and pressure drop characteristics of R22 in adiabatic capillary tubes of inner diameters of 1.2 to 2.0mm, and tube lengths of 500 to 2000mm. Distributions of temperature and pressure along capillary tubes and the refrigerant flow rates through the tubes were measured for several condensing temperatures and various degrees of subcooling at the capillary tube inlet. Condensing temperatures of R22 were selected as 40, 45, and 50$^{\circ}C$ at the capillary tube inlet, and the degree of subcooling was adjusted to 1 to 18$^{\circ}C$. Experimental results including mass flow rates and pressure drops of R22 in capillary tubes were provided. A new correlation based on Buckingham II theorem to predict the mass flow rate through the capillary tube was presented considering major parameters which affect the flow and pressure drop characteristcis.

  • PDF