• Title/Summary/Keyword: Flow rate characteristic

Search Result 478, Processing Time 0.03 seconds

Mass transfer characteristics of continuous electrocoagulation for dyestuff solution using aluminum flat plate electrode (Al 전극에 의한 염료의 전기응집에서 물질전달 특성)

  • Kim, Tak-Hyun;Park, Chulhwan;Shin, Eung-Bai;Kim, Sangyong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.290-291
    • /
    • 2001
  • The relationship between velocity, viscosity, diffusion coefficient, mass transfer coefficient and characteristic length and mass transfer data can be correlated by dimensionless relationship in electrolytic process. The performance of dyestuff removal was decreased as the flow rate of electrolyte was increased. It was due to the effect of retention time decreasing was superior to that of turbulent inlet mixing. Sh/Sc$\^$1/3/ vs Re plot for Al flat electrode did not showed the general tendency of the relationship between Sh/Sc$\^$1/3/ and Re. It can be thought that flow rate was not sufficiently high to increase the effect of mixing.

A Numerical Study on the Effect of Volute Geometry on the Performance of Centrifugal Pump (볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Deok-Su;Jeon, Sang-Gyu;Yoon, Joon-Yong;Choi, Young-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.44-49
    • /
    • 2006
  • In this study, the effects of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate, the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

A Numerical Study on the effect of Volute Geometry on the Performance of Centrifugal Pump (볼류트 형상이 원심 펌프의 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Deok-Su;Choi, Young-Seok;Jeon, Sang-Gyu;Yoon, Joon-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.497-502
    • /
    • 2005
  • In this study. the effect of volute area distribution on the performance of a centrifugal pump were numerically studied using a commercial CFD code. To reduce the shutoff head, maintaining head and efficiency at a design flow rate. the flat head-capacity characteristic curves in which the head varies only slightly with capacity from shutoff to design capacity are frequently required. In order to control the shutoff head of a pump, several volute cross-sectional area distributions were proposed as a main parameter with the same impeller geometry. The calculation results show that the slope of the performance characteristic curve of the centrifugal pump can be controlled by modifying the area distribution from volute tongue to volute outlet with fixed volute outlet area and also varied volute outlet area.

  • PDF

Numerical Study of Characteristic of Heat and Mass Transfer in Planar Membrane Humidifier According to Flow Direction (연료전지용 판형 막 가습기의 유동방향에 따른 열 및 물질전달 특성에 관한 해석적 연구)

  • Yun, Sungho;Byun, Jae Ki;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.503-511
    • /
    • 2013
  • The humidifying supply gas is important in terms of the performance efficiency and membrane life improvement of a PEM fuel cell. A planar membrane humidifier is classified as a cross-flow and counter-flow type depending on the flow direction, and heat and mass transfer occur between the plate and the membrane. In this study, the changes in heat and mass transfer for various inlet temperatures and flow rates are compared according to the flow direction by using the sensible and latent ${\varepsilon}$-NTU method. The obtained results indicate that the counter flow shows higher heat and mass transfer performance than the cross flow at a low flow rate, and the difference in performance decreases as the flow rate increases. Furthermore, changes in the mass transfer performance decrease considerably with a nonlinear increase in the inlet temperature, and variations of the heat transfer performance are small.

The Role of Slits and Swirl Vanes on the Turbulent Flow Fields in Cone Type Gas Burner (콘형 가스버너의 난류유동장에 대한 슬릿과 스월베인의 역할)

  • Kim, Jang-Kweon;Jeong, Kyu-Jo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.341-346
    • /
    • 2001
  • The gun-type gas burner adopted in this study is generally composed of some slits and swirl vanes. Therefore, this paper is studied to investigate the effect of slits and swirl vanes on the turbulent flow fields in the horizontal plane of gas swirl burner with a cone type baffle plate measured by using X-probe from hot-wire anemometer system. This experiment is carried out at flow rate $450\;{\ell}/min$, which is equivalent to the combustion air flow rate necessary for heat release 15,000 kcal/hr in gas furnace, in the test section of subsonic wind tunnel. When the burner has only swirl vanes, the axial mean velocity component shows the characteristic that spreads more remarkably toward radial direction than axial one, but when it has only slits, that is developed spreading more toward axial direction than radial one. Therefore, because the biggest speed is spurted in slits and it derive main flow toward axial direction encircling rotational flow that comes out from swirl vane that is situated on the inside of slits, both slits and swirl vanes composing of cone type gas burner act role that decreases the speed near slits and increases the flow speed in the central part of a burner. Moreover, because rotational flow by swirl vanes and fast jet flow by slits increase turbulent intensities effectively coexisting, the turbulent kinetic energy is distributed with a bigger size fairly near slits than burner models which have only slit or swirl vanes within X/R<0.6410.

  • PDF

Characteristic of the Formation and Adhesion of Ice on a Cooling Surface by a Stirring Aqueous Solution

  • Kang, Chae-Dong;Seung, Hyun;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.110-117
    • /
    • 2006
  • Ice adhesion or cohesion leads to the decrease of the performance of ice making system, especially to dynamic type ice thermal storage system (DISS) which mainly forms ice from the flow of an aqueous solution. The ice adhesion is influenced by various parameters associated with operating or geometric condition. In this study, the influence on an adhesion of ice to the characteristic of cooling surface and to composition of an aqueous solution was fundamentally observed by using batch type cooling device,. a beaker. Three patterns of solution in each beaker were cooled with brine. Moreover, the characteristic of cooling surface on each beaker was distinguished to coating materials. Stirring power as a degree of the ice adhesion was measured. The stirring power to cooling heat transfer rate in each beaker was compared. As a result, the lowest stirring power of 8.9 W with non-adhesion of ice, was shown in the case of the aqueous solution of EG(4) + PG(1.5) + 1,6HD(1.5). in PE coating beaker.

The Effect of Pad Groove Dimension on Polishing Performance in CMP (CMP에서 패드 그루브의 채수가 연마특성에 미치는 영향)

  • Park, Ki-Hyun;Kim, Hyung-Jae;Jeong, Young-Seok;Jeong, Hae-Do;Park, Jae-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1308-1311
    • /
    • 2004
  • It is very important that get polishing characteristic that to be stable that accomplish planarization of high efficiency in chemical mechanical polishing, and there is repeatability Groove of pad causes much effects in flow of slurry among various factors that influence in polishing characteristic, is expected to cause change of lubrication state and polishing characteristic in contact between wafer and pad. Therefore, divided factors of pad groove by groove pattern, groove profile, groove dimensions. This research wishes to study effect that dimension of pad groove gets in polishing performance. When changed dimension (width, depth, pitch of groove) of groove, measured change of removal rate and friction force. According as groove dimension changes, could confirm that removal rate and friction force change. While result of this experiment studies effect of pad groove in CMP, it is expected to become small help.

  • PDF

Performance Characteristics of a Cross-Flow Fan with Various Impeller Outlet Angles and Rearguiders (임펠러 출구각 및 리어가이더 형상 변화에 따른 횡류홴의 성능 특성)

  • Kim, H.S.;Kim, D.W.;Yoon, T.S.;Park, S.K.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.851-856
    • /
    • 2003
  • A cross-flow fan consists of an impeller, a stabilizer and a rearguider. When it applied for an air conditioner, an evaporator should be added. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there are a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, the reciprocal relation between the impeller and the flow passage is the important factor for performance improvement of the cross-flow tan because each parameter is independent. The performance characteristics in the cross-flow fan are graphically depicted with various impeller outlet angles and rearguiders.

  • PDF

Performance Prediction Method of Hybrid Rocket Motors with Local Variance of Combustion (국부연소 후퇴율을 고려한 하이브리드로켓의 성능예측 기법연구)

  • Cho, Min-Gyung;Heo, Jun-Young;Park, Hyung-Ju;Kim, Jin-Kon;Moon, Hee-Jang;Sung, Hong-Gye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • An unsteady internal ballistic performance model was proposed to take account for the variance of local regression rate along the grain port of a hybrid rocket combustor. The characteristic parameters of hybrid rocket motor was investigated. The performance model of concern in the study was fairly comparable with the test result. The combustion coefficients and local burning characteristics of a hybrid rocket motor were evaluated. The local variation of the oxidizer mass flow rate results in the changes of local regression rate, pressure, temperature, and gas velocity to flow direction, which was analyzed quantitatively.

LOS Evaluation of Urban Freeway by the Occupancy Characteristics (점유율 특성을 이용한 도시고속도로의 서비스수준(LOS) 평가에 관한 연구)

  • Kim, Tae gon;Moon, Byoung Keun;Jo, In Kook;Jung, Yu Na
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3D
    • /
    • pp.335-345
    • /
    • 2009
  • Generally, density is used as a measure of effectiveness (MOE) of the level of service (LOS) for the basic segment of the roadway facility, but can not express the operational condition of the roadway facility properly because there can be an error in the computed density compared with the density measured in the field. Thus, the purpose of this study is to investigate the real-time traffic characteristic data (traffic flow, speed, occupancy, headway, spacing, etc.) from the detectors installed on the mainline section of urban freeway under the study, analyze the maximum flow rate from the relationship between the real-time traffic characteristics collected, and evaluate the LOS criteria within the basic segment of the urban freeway based on the relationship between the occupancy and the v/c ratio depending on the level of service.