Performance Characteristics of a Cross-Flow Fan with Various Impeller Outlet Angles and Rearguiders

임펠러 출구각 및 리어가이더 형상 변화에 따른 횡류홴의 성능 특성

  • 김형섭 (성균관대학교 기계공학부 대학원) ;
  • 김동원 (성균관대학교 기계공학부 대학원) ;
  • 윤태석 (삼성전자 DA 연구소) ;
  • 박성관 (삼성전자 DA 연구소) ;
  • 김윤제 (성균관대학교 기계공학부)
  • Published : 2003.11.05

Abstract

A cross-flow fan consists of an impeller, a stabilizer and a rearguider. When it applied for an air conditioner, an evaporator should be added. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there are a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, the reciprocal relation between the impeller and the flow passage is the important factor for performance improvement of the cross-flow tan because each parameter is independent. The performance characteristics in the cross-flow fan are graphically depicted with various impeller outlet angles and rearguiders.

Keywords