• Title/Summary/Keyword: Flow path

Search Result 994, Processing Time 0.025 seconds

Network Structures of The Metropolitan Seoul Subway Systems (서울 대도시권 지하철망의 구조적 특성 분석)

  • Park, Jong-Soo;Lee, Keum-Sook
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.459-475
    • /
    • 2008
  • This study analyzes the network structure of the Metropolitan Seoul subway system by applying complex network analysis methods. For the purpose, we construct the Metropolitan Seoul subway system as a network graph, and then calculate various indices introduced in complex network analysis. Structural characteristics of Metropolitan Seoul subway network are discussed by these indices. In particular, this study determines the shortest paths between nodes based on the weighted distance (physical and time distance) as well as topological network distance, since urban travel movements are more sensitive for them. We introduce an accessibility measurement based on the shortest distance both in terms of physical distance and network distance, and then compare the spatial structure between two. Accessibility levels of the system have been getting up overall, and thus the accessibility gaps have been getting lessen between center located subway stops and remote ones during the last 10 years. Passenger traffic volumes are explored from real passenger transaction databases by utilizing data mining techniques, and mapped by GIS. Clear differences reveal between the spatial patterns of real passenger flows and accessibility. That is, passenger flows of the Metropolitan Seoul subway system are related with population distribution and land use around subway stops as well as the accessibility supported by the subway network.

  • PDF

Various Meanings of Wolji Pond Construction in Shilla Dynasty (월지 조성 목적의 중의성(重意性) 고찰)

  • Hong, Kwang-Pyo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.3
    • /
    • pp.67-77
    • /
    • 2016
  • This study was initiated from question raised on existing study achievement that purpose for Wolji construction simply was to build gardens. In this research, after raising a question on existing theory about the Wolji construction, another purpose of Wolji construction is investigated. Study result is as follows. First, two questions raised on Wolji construction are "Was Wolji constructed as a garden from the beginning?" and "Was Wolji region available land as now at time of creation?" However, it was verified that the purpose of Wolji construction was to use not as a garden but as a detention pond, and the land of such region was unserviceable at time of Wolji construction. Second, in terms of locations and Topography, it was confirmed that Wolji has a favorable condition for undercurrent function as it is positioned at the end point of flow path formed by gushout water spurting from the water flooded from Bukcheon, or low and wetland. Third, from hydraulic point of view, Bukcheon always has a possibility of flooding occurrence before completing river bank build up, and such flooding damage was curved at Guhwangdongwonji, and at Wolji once again in order to prevent the damage spread into the center of Wanggyeong. Fourth, from urban planning point of view, it was confirmed that urban functions were not established in Wolji region before Wolji construction, and urban planning was completed through the opening of roads and others, after Wolji construction. Fifth, it was confirmed that inflow and outflow device of Wolji, and vertical stone platform at western side of Wolji were the facilities to provide sufficient functions as detention ponds.

Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse (온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

Application of nightlight satellite imagery for assessing flooding potential area in the Mekong river basin (메콩강 홍수위험분석을 위한 나이트라이트 위성영상 적용성 검토)

  • Try, Sophal;Lee, Daeup;Lee, Giha
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.565-574
    • /
    • 2018
  • High population density in deltaic settings, especially in Asia, tends to increase and causes coastal flood risk because of lower elevations and significant subsidence. Large flood annually causes numerous deaths and huge economic losses. In this paper, an innovative technology of spatial satellite imagery has been used as tool to analyze the socio-economic flood-related damage in Mekong river basin. The relationship between nightlight intensity and flood damages has been determined for the period of 1992-2013 with a spatial resolution of 30 arc sec ($0.0083^{\circ}$), which is nearly one kilometer at the equator. Flow path distance was calculated to identify the distance of each cell to river network and to examine how nightlight intensity correlate to the area close to and far from river network. Statistical analysis results highlight the significant correlation between nocturnal luminosity intensity and flood-related damages in countries along the Mekong river (i.e., Cambodia, China, Lao PDR, Thailand, and Vietnam). This result reveals that the areas close to the river network correspond to high human distribution and causes huge damage during flooding. The result may provide key information to the region with respect to decisions, attentions, and mitigation strategies.

Optimal valve installation of water distribution network considering abnormal water supply scenarios (비정상 물공급 시나리오를 고려한 상수도관망 최적 밸브위치 결정)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.719-728
    • /
    • 2019
  • Valve in water distribution network (WDN), that controls the flow in pipes, is used to isolate a segment (a part of WDN) under abnormal water supply conditions (e.g., pipe breakage, water quality failure event). The segment isolation degrades pressure and water serviceability in neighboring area during the water service outage of the segment. Recent hydraulic and water quality failure events reported encouraging WDN valve installation based on various abnormal water supply scenarios. This study introduces a scenario-based optimal valve installation approach to optimize the number of valves, the amount of undelivered water, and a shortest water supply path indicator (i.e., Hydraulic Geodesic Index). The proposed approach is demonstrated in the valve installation of Pescara network, and the optimal valve sets are obtained under multiple scenarios and compared to the existing valve set. Pressure-driven analysis (PDA) scheme is used for a network hydraulic simulation. The optimal valve set derived from the proposed method has 19 fewer valves than the existing valve set in the network and the amount of undelivered water was also lower for the optimal valve set. Reducing the reservoir head requires a greater number of valves to achieve the similar functionality of the WDN with the optimal valve set of the original reservoir head. This study also compared the results of demand-driven analysis (DDA) and the PDA and confirmed that the latter is required for optimal valve installation.

Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating (선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구)

  • Jang, Sung-Cheol
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.63-68
    • /
    • 2021
  • Domestic electric heater manufacturers are focusing on technology development to improve the efficiency of existing products. The electric heater for ship fuel is large in size and has high difficulty in miniaturization/high efficiency, so there are not many companies that try to develop technology yet. The existing electric heater has a structure of low heating efficiency because the contact time with the heat exchange tube of the heating medium is very short because the flow path of the ship engine fuel is monotonous. Since it is manufactured in a tubular shape, the volume is very large regardless of the heating efficiency. As a result, the tubular electric heater device applied by overseas advanced companies has difficulty in maintaining and repairing because it is necessary to decompose all tubular heaters when a specific part of the inside is damaged and if the heat exchange tube is damaged, all the heat exchange tubes must be decomposed. In this study, a basic study on plate type electric heaters capable of heating 10 tons of ship engine fuel per hour and setting a maximum temperature of up to 150℃ was conducted through a 250kW capacity plate type electric heater.

An Analysis Model on Passenger Pedestrian Flow within Subway Stations - Using Smart Card Data - (지하철역사내 승객보행흐름 분석모형 - 교통카드자료를 활용하여 -)

  • Lee, Mee Young;Shin, Seongil;Kim, Boo Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.6
    • /
    • pp.14-24
    • /
    • 2018
  • Pedestrian movement of passengers using smart card within stations can be divided into three types of activities - straight ride and alight, line transfer, and station transfer. Straight ride and alight is transfer activity for which the card terminal and embarking line are identical. In this case, straight ride occurs at the origin station and straight alight occurs at the destination station. Line transfer refers to activity in which the subway line embarked on by the passenger is different from that which is disembarked. Succinctly, line transfer is transfer at a middle station, rather than at origin or destination stations. Station transfer occurs when the card terminal line and embarking line are different. It appears when station transfer happens at the origin station as starting transfer, and at the destination station as destination transfer. In the case of Metropolitan smart card data, origin and destination station card terminal line number data is recorded, but subway line data does not exist. Consequently, transportation card data, as it exists, cannot adequately be used to analyze pedestrian movement as a whole in subway stations. This research uses the smart card data, with its constraints, to propose an analysis model for passenger pedestrian movement within subway stations. To achieve this, a path selection model is constructed, which links origin and destination stations, and then applied for analysis. Finally, a case study of the metropolitan subway is undertaken and pedestrian volume analyzed.

A Study on the Influencing Factors of Overuse of the Seniors's Mobile Short Form Video (중장년층 모바일 숏폼 동영상 과다사용 행위의 영향요인 연구)

  • Han, Jing;Bae, Seung-Ju;Kwon, Mahn-Woo;Lee, Sang-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.173-184
    • /
    • 2022
  • Focusing on the TikTok, this paper studies the factors that influence the use intention, flow and addiction of the elderly in short videos from three aspects of media attraction, perceived usefulness and user characteristics through quantitative research methods. In recent years, influenced by various factors, more and more seniors have begun to indulge in short form videos, which will do harm to their physical and mental health. Therefore, the researchers believe it is necessary to identify the behavioral intention of seniors and the path to addiction. According to the research results, the attractiveness of TikTok and the characteristics of seniors have a positive impact on the usefulness of media. In addition, the study confirms that media usefulness has an impact on use intention and use behavior, which may develop into immersion and addiction. This study not only supplements the classical TAM theory, but also provides a reference for helping seniors to use the Internet in a healthy way. The researchers look forward to expanding the research on the various Internet platforms used by seniors in different countries and regions.

Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR (가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석)

  • Ha, G.S.;Kim, W.S.;Chang, W.P.;Yoo, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.859-869
    • /
    • 1995
  • The present study is to understand the physical phenomena anticipated during the accident with RHR loss under mid-loop operation in a PWR and, at the same time, to examine the prediction capability of RELAP5/MOD3.1 on such an accident, by simulating an integral test relevant to this accident for reliable analysis in an actual PWR. The selected experiment, i.g. BETHSY Test 6.9a, represents the configuration with the pressurizer manway open and steam generators unavailable during the accident. Accordingly, the results of this ok are sure to contribute to understanding both the key events as well as the sensitive parameters, anticipated in the accident, for validity of the actual analysis. In the simulation result overall behavior as well as major phenomena observed in the experiment have been predicted reasonably by RELAP5/MOD3.1, however, the problem associated with enormous computing time .due to small time step size has been encountered. Besides, the code prediction of higher swollen level in the pressure vessel has given rise to overestimation of both pressurizer level and RCS pressure. Subsequently, overprediction of the break flow through the manway has led to earlier core uncovery than that in the experiment by about 400 seconds. As a whole, it is demonstrated from both the experiment and the analysis that gravity feed has not been sufficient to recover the core level and thus additional forced feed has been necessary in this configuration.

  • PDF

Classification of Wind Corridor for Utilizing Heat Deficit of the Cold-Air Layer - A Case Study of the Daegu Metropolitan City - (냉각에너지를 활용한 바람길 구성요소 분류 - 대구광역시를 사례로 -)

  • Sung, Uk-Je;Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.5
    • /
    • pp.70-83
    • /
    • 2023
  • Recently, the Korea Forest Service has implemented a planning project about wind corridor forests as a response measure to climate change. Based on this, research on wind corridors has been underway. For the creation of wind corridor forests, a preliminary evaluation of the wind corridor function is necessary. However, currently, there is no evaluation index to directly evaluate and spatially distinguish the types of wind corridors, and analysis is being performed based on indirect indicators. Therefore, this study proposed a method to evaluate and classify wind corridors by utilizing heat deficit analysis as an evaluation index for cold air generation. Heat deficit was analyzed using a cold air analysis model called Kaltluftabflussmodell_21 (KLAM_21). According to the results of the simulation analysis, the wind path was functionally classified. The top 5% were classified as cold-air generating Areas (CGA), and the bottom 5% as cold-air vulnerable Areas (CVA). In addition, the cold-air flowing Areas (CFA) were classified by identifying the flow of cold air moving from the cold air generation area. It is expected that the methodology of this study can be utilized as an evaluation method for the effectiveness of wind corridors. It is also anticipated to be used as an evaluation index to be presented in the selection of wind corridor forest sites.