• Title/Summary/Keyword: Flow oscillation

Search Result 510, Processing Time 0.029 seconds

Novel nonequilibrium microwave emission and current-voltage characteristics of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+d}$ intrinsic Josephson junction mesas

  • Kim, Sun-Mi;Lee, Kie-Jin;Bae, Myung-Ho;Lee, Hu-Jong;Cha, Deok-Joon;Takayuki Ishibashi;Katsuaki Sato;Kim, Jin-Tae
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.104-108
    • /
    • 2003
  • We have measured the transport properties of $Bi_2$$Sr_2$$CaCu_2$$O_{8+d}$ (BSCCO) intrinsic Josephson junction mesa. Transport measurements with current flow along the c-axis, perpendicular to the layer of mesa showed multi-branch structures on the current-voltage characteristics. For single intrinsic junctions, the microwave radiation appears in the form of three different modes of oscillations, which include Josephson emission, nonequilibrium broad emission and sharp coherent microwave emission. Mutual phase interactions between two-mesas structures of BSCCO intrinsic Josephson junctions were studied. The results were explained within the framework of the Josephson plasma excitation model due to quasiparticle injection.n.

  • PDF

Numerical Simulation of Edge Tone by Finite Difference Lattice Boltzmann Model with Internal Degree of Freedom (내부자유도를 갖는 차분래티스볼츠만 모델에 의한 에지톤의 수치계산)

  • Kang Ho-Keun;Kim Eun-Ra;Oh Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.929-937
    • /
    • 2005
  • A lattice BGK model based on a finite difference scheme with an internal degree of freedom is employed and it is shown that a diatomic 9as such as air is successfully simulated In a weak compressive wane problem and Coutte flow, the validity and characteristics of the applied model are examined. With the model. furthermore. we present a 2-dimensional edge tones to predict the frequency characteristics of discrete oscillations of a jet-edge feedback cycle by the FDLB model (I.D.F FDLBM) in which any specific heat ratio $\gamma$ can be chosen freely. The jet is chosen long enough in order to guaranteed the Parabolic velocity profile of a jet at the outlet. and the edges have of an angle of $\alpha$=$23^{0}$ and $20^{0}$. A sinuous instability wane with real frequency resulting from Periodic oscillation of the jet around the edge is propagated on the upper and lower of wedge.

Passive Control of the Vortex Shedding past a Square Cylinder with Moving Ground Part II Study of Passive Control Technique (지면 운동에 따른 정사각주 후류의 와류 유동장 수치 해석 Part II. 수동 제어 기법 연구)

  • Kim, Tae-Yoon;Lee, Bo-Sung;Lee, Dong-Ho;Kohama, Y.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.8-14
    • /
    • 2005
  • Understanding of the flow past a bluff body close to a moving ground is very important in automobile and aeronautical fields because of aerodynamic characteristic and instability induced by unsteady vortex shedding. The passive control method that mounted the vertical and horizontal plates at the lower surface of the cylinder is studied to suppress the unsteady oscillation motion. When the grounds moves, the diminish of the shear layer on the ground promotes the interaction between the lower and the upper separated shear layers of the cylinder, hence vortex shedding occurs at the lower gap height than the stationary ground.

Organic fouling in forward osmosis (FO): Membrane flux behavior and foulant quantification

  • Xia, Shengji;Yao, Lijuan;Yang, Ruilin;Zhou, Yumin
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.161-172
    • /
    • 2015
  • Forward osmosis (FO) is an emerging membrane technology with potential applications in desalination and wastewater reclamation. The osmotic pressure gradient across the FO membrane is used to generate water flux. In this study, flux performance and foulant deposition on the FO membrane were systematically investigated with a co-current cross-flow membrane system. Sodium alginate (SA), bovine serum albumin (BSA) and tannic acid (TA) were used as model foulants. Organics adsorbed on the membrane were peeled off via oscillation and characterized by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). When an initial flux of $8.42L/m^2h$ was applied, both flux reduction and foulant deposition were slight for the feed solution containing BSA and TA. In comparison, flux reduction and foulant deposition were much more severe for the feed solution containing SA, as a distinct SA cake-layer was formed on the membrane surface and played a crucial role in membrane fouling. In addition, as the initial SA concentration increased in FS, the thickness of the cake-layer increased remarkably, and the membrane fouling became more severe.

Power Current Control of a Resonant Vibratory Conveyor Having Electromagnetic Drive

  • Despotovic, Zeljko V.;Ribic, Aleksandar I.;Sinik, Vladimir M.
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.677-688
    • /
    • 2012
  • The vibratory conveyors with electromagnetic drive are used for performing gravimetric flow of granular materials in processing industry. By realizing free vibrations of variable intensity and frequency over a wide range through application of the electromagnetic actuator, suitable power converter, and the corresponding controller, continuous conveyance of granular materials have been provided for various operating conditions. Standard power output stages intended for control of vibratory conveyance using thyristors and triacs. Phase angle control can only accomplish tuning of amplitude oscillations, but oscillation frequency cannot be adjusted by these converters. Application of current controlled transistor converters enables accomplishing the amplitude and/or frequency control. Their use implies the excitation of a vibratory conveyor independent of the supply network frequency. In addition, the frequency control ensures operation in the region of mechanical resonance. Operation in this region is favourable from the energy point of view, since it requires minimal energy consumption. The paper presents a possible solution and advantages of the amplitude-frequency control of vibratory conveyors by means of a current controlled power converter.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power trajectory in Complex plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 탁소전력의 궤적변화)

  • Kwon, O.S.;Kim, C.H.;Park, N.O.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.310-312
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load the oscillation can be severe and even increase largely and finally the out-of-step condition may occur During the power swing and out-of-step conditions, the a apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

  • PDF

A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines (2도체 송전선로의 스페이서 취부방식 연구)

  • Min, Byeong-Wook;Kim, Woo-Kyum;Choi, Han-Yeol;Park, Kee-Yong;Kim, Won-Jin;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

A Study of Computation Methods for Dynamic Damping Coefficients of an Airship (비행선의 동적 감쇠계수 계산 방법에 관한 연구)

  • Park, Su Hyeong;Jang, Byeong Hui;Kim, Yu Jin;Gwon, Jang Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.10-17
    • /
    • 2003
  • Dynamic stability is critically required to stabilize an airship which is statically unstable. Numerical computations were performed in order to support and confirm the foced oscillation wind tunnel tests. To analyze the low-speed flow filed around the airship, a low-Mach number preconditioned method was applied. Using two computation methods, variations of the dynamic damping coefficients were examined. Numerical results show that it is dynamically stable for three directional moments, but unstable for normal or side force. It is revealed that the damping coefficients are more sensitive to the direction of the angular rate than the angle of attack or the magnitude og angular rate.

Development of Multi-dimensional Limiting Process for Multi-dimensional Compressible Flow (다차원 압축성 유동 해석을 위한 MLP 기법의 개발)

  • 윤성환;김종암;김규홍
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.7
    • /
    • pp.1-11
    • /
    • 2006
  • Through the analysis of conventional TVD limiters, a new multi-dimensional limiting function is derived for an oscillation control in multi-dimensional flows. Then, Multi-dimensional Limiting Process (MLP) is developed with the multi-dimensional limiting function. The major advantage of MLP is to prevent oscillations across a multi-dimensional discontinuity, and it is readily compatible with more than 3rd order spatial interpolation. Moreover, MLP shows a good convergence characteristic in a steady problem and it is very simple to be implemented. Through numerical test cases, it is verified that MLP substantially improves accuracy, efficiency and robustness both in continuous and discontinuous flows.

An Approximate Analytical Method for Hydrodynamic Forces on Oscillating Inner Cylinder in Concentric Annulus (동심원내에서 진동하는 내부 실린더에 작용하는 유체유발력의 근사적 해법)

  • 심우건
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.861-869
    • /
    • 1997
  • An approximate analytical method has been developed for estimating hydrodynamic forces acting on oscillating inner cylinder in concentric annulus. When the rigid inner cylinder executes translational oscillation, fluid inertia and damping forces on the oscillating cylinder are generated by unsteady pressure and viscous skin friction. Considering the dynamic-characteristics of unsteady viscous flow and the added mass coefficient of inviscid fluid, these hydrodynamic forces including viscous effect are dramatically simplified and expressed in terms of oscillatory Reynolds number and the geometry of annular configuration. Thus, the viscous effect on the forces can be estimated very easily compared to an existing theory. The forces are calculated by two models developed for relatively high and low oscillatory Reynolds numbers. The model for low oscillatory Reynolds number is suitable for relatively high ratio of the penetration depth to annular space while the model for high oscillatory Reynolds number is applicable to the case of relatively low ratio. It is found that the transient ratio between two models is approximately 0.2~0.25 and the forcea are expressed in terms of oscillatory Reynolds number, explicity. The present results show good agreements with an existing numerical results, especially for high and low penetration ratios to annular gap.

  • PDF