• Title/Summary/Keyword: Flow noise

Search Result 1,720, Processing Time 0.028 seconds

Quantitative Measurement of the Glottal Area Waveform(GAW) in Unilateral Vocal Fold Paralysis (편측성대마비환자에서의 성문면적파형(Glottal Area Waveform)의 정량적 측정)

  • 최홍식;김명상;최재영;안성윤;이세영;홍정표
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.71-78
    • /
    • 1998
  • Type Ⅰ thyuroplasty in conjunction with arytenoid adduction is one of the excellent techniques in the treatment of unilateral vocal fold paralysis. But perioperative objective evaluation of the patients is difficult. With the development of the videostroboscopy and image analysis program, we could quantify the Glottal Area Waveform(GAW) in patients with unilateral vocal fold paralysis and investigated the relationship between the glottal area and aerodynamic and acoustic parameters. Eight female patients who were performed type Ⅰ thyroplasty in conjunction with arytenoid adduction and 5 females with normal vocal function were involved in this study. Preoperative and postoperative videostroboscopy and vocal function study wire performed. GAW was analysed quantitatively with image analysis program (Kay Stroboscope Image analysis, KSIP) Peak Glottal Area(PGA), Baseline Offset(BO), and Closing Phase(CP) were increased in patients with unilateral vocal fold paralysis and they were reduced after the operation. Mean flow Rate (MFR) was well correlated with the PGA in normal control group and unilateral vocal fold paralysis patients. Noise to harmonic ratio(NHR) was correlated with PGA only in preoperative unilateral vocal fold paralysis patients. In conclusion quantitative measurement of the GAW is useful method in evaluation of unilateral vocal f31d paralysis patients.

  • PDF

A Study on the Characteristics of the Tube-to-Support Dynamic Impact Force Measurement Facility (튜브와 지지대 사이의 동적상호 충격력 측정장치 특성규명에 관한 연구)

  • 김일곤;박진무
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1995
  • Flow-induced vibration in heat exchanger (or fuel rod) in nuclar power plant can cause dynamic interactions between tubes and tube supports resulting in fretting-wear. To increase the reliability and design life of heat exchanger components, design criteria that establish acceptable limits of vibration and minimize fretting wear are necessary. The fretting-wear rate is dependent upon material combination, contact configuration, environmental conditions and tube-to tube support dynamic interaction. It is demostrated that the fretting -wear rate correlates well with tube-to-support contact force or work rate. The tube-to-support dynamic interaction, which consists of dynamic contact forces and tube motion, is used to relate single-span wear data to real heat exchanger configurations consisting of multi-span tube bundles. This paper describes the test facility to measure tube-to-support dynamic impact force and reports its dynamic characteristics through the four impact tests - a force transduces independent and external impact tests, central ring inside impact test and additional cylinder impact test. Through the tests the impact parameter change dependent upon the material difference of impacting ball is studied, and the impact parameters of Force Transducer Assembly components are measured. And also the dynamic behavior of Force Transducer Assembly is analyzed. The force measurement technique herein is shown to provide a reasonable measure of dynamic contact forces.

  • PDF

Properties of the Amorphous Silicon Microbolometer using PECVD (PECVD 이용한 비정질 실리콘형 마이크로 볼로미터 특성)

  • Kang, Tai Young;Kim, Kyung Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.19-23
    • /
    • 2012
  • We report microbolometer characteristic with n-type and p-type amorphous silicon thin film. The n-type and p-type amorphous silicon thin films were made by PECVD. The electrical properties of n-type and p-type a-Si:H thin films were investigated as a function of doping gas flow rate. The doping gas used $B_2H_6/Ar$ (1:9) and $PH_3/Ar$ (1:9). In general, the conductivity of doping a-Si:H thin films increased as doping gas increase but the conductivity of a-Si:H thin films decreased as the doping gas increase because doping gas concentration increase led to dilution gas (Ar) increase as the same time. We fabricated an amorphous silicon microbolometer using surface micromachining technology. The fabricated microbolometer had a negative TCR of 2.3%. The p-type microbolometer had responsivity of $5{\times}10^4V/W$ and high detectivity of $3{\times}10^8cm(Hz)^{1/2}/W$. The p-type microbolometer had more detectivity than n-type for less noise value.

Daily Rainfall Simulation by Rainfall Frequency and State Model of Markov Chain (강우 빈도와 마코프 연쇄의 상태모형에 의한 일 강우량 모의)

  • Jung, Young-Hun;Kim, Buyng-Sik;Kim, Hung Soo;Shim, Myung-Pil
    • Journal of Wetlands Research
    • /
    • v.5 no.2
    • /
    • pp.1-13
    • /
    • 2003
  • In Korea, most of the rainfalls have been concentrated in the flood season and the flood study has received more attention than low flow analysis. One of the reasons that the analysis of low flows has less attention is the lacks of the required data like daily rainfall and so we have used the stochastic processes such as pulse noise, exponential distribution, and state model of Markov chain for the rainfall simulation in short term such as daily. Especially this study will pay attention to the state model of Markov chain. The previous study had performed the simulation study by the state model without considerations of the flood and non-flood periods and without consideration of the frequency of rainfall for the period of a state. Therefore this study considers afore mentioned two cases and compares the results with the known state model. As the results, the RMSEs of the suggested and known models represent the similar results. However, the PRE(relative percentage error) shows the suggested model is better results.

  • PDF

A Simulation Method for Considering the Outdoor Wind-Pressure in Calculation of Indoor Air-Flow in High-Rise Buildings (건물 내 공기유동 해석에 외부 바람이 미치는 영향의 분석)

  • Kim, Dae-Young;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.55-62
    • /
    • 2016
  • The air flows in building caused by thermal buoyancy, known as the stack effect, have a pronounced influence on both the indoor environment (thermal environment, noise, draught and contaminant diffusion) and energy needs in high-rise buildings. Prior studies for airflow in high-rise buildings were focused on the degree of stack effect and countermeasures. The wind pressure was neglected during the calculation of the indoor airflow in high-rise buildings to clarify the effect of thermal buoyancy in previous studies. However, wind is an important driving force of indoor airflows in buildings with the stack effect. In this study, the effect of wind pressure on indoor airflow in high-rise building when the stack effect is dominant in winter was analyzed. In this paper, methods that involved considering the wind pressure in airflow network simulation were analyzed.

Recent Technology Trends and Future Prospects for Image Sensor (이미지 센서의 최근 기술 동향과 향후 전망)

  • Park, Sangsik;Shin, Bhumjae;Uh, Hyungsoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • The technology and market size of image sensors continue to develop thanks to the release of image sensors that exceed 100 million pixels in 2019 and expansion of black box camera markets for vehicles in addition to existing mobile applications. We review the technology flow of image sensors that have been constantly evolving for 40 years since Hitachi launched a 200,000-pixel image sensor in 1979. Although CCD has made inroads into image sensor market for a while based on good picture quality, CMOS image sensor (CIS) with active pixels has made inroads into the market as semiconductor technology continues to develop, since the electrons generated by the incident light are converted to the electric signals in the pixel, and the power consumption is low. CIS image sensors with superior characteristics such as high resolution, high sensitivity, low power consumption, low noise and vivid color continue to be released as the new technologies are incorporated. At present, new types of structures such as Backside Illumination and Isolation Cell have been adopted, with better sensitivity and high S/N ratio. In the future, new photoconductive materials are expected to be adopted as a light absorption part in place of the pn junction.

A New Fault Diagnosis Scheme between L1 Signals Using IES on the Metric Defined via Kalman Filter and Exponential Function Transformation (칼만추정과 초월함수 사영을 통한 L1 신호간의 거리 Metric에 IES을 적용한 새로운 고장진단 기법)

  • Kim, Sung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • Measuring the distances between signals in the signal space is usually determined by obtaining the ideal metric which is not easy to obtain. In this research we have investigated the scheme that measures the distances between the signals constructed with the measured voltage signals connected to electric apparatus using Kalman filter and exponential mapping. The metric is defined on the feature signals obtained via the estimation process of a Kalman filter and the mapping process using the exponential transformation. Diagnosis is on the voltage fluctuations is applied to determining whether the system is in the stable state or not due to the unexpected accidents, such as power overcharge, discharge, outages flow may be the cause of the accident. The decision making scheme evaluated with respect to the effectiveness and the degree of complication with different variances. Two methods, the Hard Limit Threshold Scheme(HLTS) and the Interval Energy Scheme(IES) are proposed and compared. In experiments the IES shows better tolerance to impulse noise than the HLTS.

Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device (PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술)

  • Kim, Yong-Jung;Na, Jeaho;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

Vibrational Power Analysis of Multi-dimensional Vibration System with Rotational Terms Included and Its Application to Compressor System (회전 변형 파워항을 고려한 진동 절연계 해석 : 컴프레서 마운트 계에의 응용)

  • Lee, Ho-Jung;Kim, Kwang-Joon;Lee, Byung-Chan;Jin, Sim-Won;Jung, In-Wha
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.618-623
    • /
    • 2001
  • In a practical vibration isolation system, vibration is transmitted from the source to the receiver through several paths such as more than one inter-connected point and multi-degree of freedom at each connection point. Therefore, the major path investigation for vibration transmission among them is often required in a point of view of isolation. For the path analysis of multi-dimensional vibration isolation system, it is useful to employ the concept of vibration power in high frequency range where radiation of noise from the receiver structure is concerned. The idea is simple to understand and formulate but rather complicated to apply in practice. For an accurate estimation of power flow especially over a high frequency range, it is well known in theory that rotational motions should be taken into consideration together with translational motions at inter-connected points. In reality, however, power transmissions related to rotational terms are often neglected mainly due to difficulties in the instrumentation. In this paper, necessary formula and measurable mechanical quantities for vibration power analysis will be reviewed and experimental results with rotational terms included for compressor system in a commercial air conditioner will be shown.

  • PDF

Performance of CSK Scheme for V2I Visible Light Communication

  • Kim, Hyeon-Cheol;Kim, Byung Wook;Jung, Sung-Yoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.3
    • /
    • pp.595-601
    • /
    • 2015
  • These days, research related to Intelligent Transportation System (ITS) technology is being widely considered. ITS is inevitable for future transportation systems to reduce accidents, congestion, and offer a smooth flow of traffic. The use of Visible Light Communication (VLC) in ITS systems has been considered widely because of its EMC/EMI free and LED infrastructure reusable properties. Among the VLC schemes, this study analyzed the performance of the Color Shift Keying (CSK) scheme under a Vehicle-to-Infrastructure (V2I) downlink scenario to verify the capability of CSK as a communication tool for ITS. By modeling daylight noise using the modified Blackbody radiation model, this study examined the performance of V2I VLC under daytime conditions. The relationship between BER, the communication distance, and the amount of ambient-light noises under the pre-described V2I scenario were determined by simulations.