• Title/Summary/Keyword: Flow line

Search Result 2,335, Processing Time 0.039 seconds

Experimental Investigation of Flow Oscillations in a Semi-closed Two-phase Natural Circulation Loop (준밀폐형 2상자연순환 회로 내에서의 유동 진동에 관한 실험적 연구)

  • Kim, Jong Moon;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1763-1773
    • /
    • 1998
  • In the present experimental study, the flow behavior in a semi-closed two-phase natural circulation loop was examined. Water was used as the working fluid. Heat flux, heater-inlet subcooling, and flow restrictions at the heater-inlet and at the expansion-tank-line were taken as the controlling parameters Six circulation modes were identified by changing heat flux and inlet subcooling conditions ; single-phase continuous circulation, periodic circulation (A), two-phase continuous circulation, and periodic circulations (B), (C), and (D). Among these, the single-phase and two-phase continuous-circulation modes exhibit no significant oscillations and are considered to be stable. Periodic circulation (A) is characterized by the large amplitude two-phase f10w oscillations with the temporal single-phase circulation between them, while periodic circulation (B) featured by the flow oscillations with continuous boiling inside the heater section. Periodic circulation (C) appears to be the manometric oscillation with continuous boiling. Periodic circulation (D) has the longer period than periodic circulation (B) and a substantial amount of liquid flow back and forth through the expansion-tank-line periodically ; this mode is considered the pressure drop oscillation. Parametric study shows that the increases of the inlet- and expansion-tank-line- restrictions and the decrease of inlet subcooling broaden the range of the stable two-phase(continuous circulation) mode.

A Study on Power Flow Control of UPFC by Series and Shunt Voltage Source Model (직.병렬전압원 모델에 의한 UPFC 전력조류제어에 관한 연구)

  • 정인학;김경신;정재길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, in the power system having UPFC(Unified Power Flow Controller) Power flow of certain line is controlled to desired value also power flow analysis algorithm is reposed considering power flow constraints which is capable of analysis power flow of all system. This algorithm is applied to controlling line-overloading problems and the method of is prosed. By applying this algorithm to controlling line-over loading the method of controlling UPFC is proposed and the effectiveness of controlling UPFC is proposed and the effectiveness of controlling UPFC is verified through the research of practical system. Also, the equation to set up an initial value of stories and shunt voltage source of UPFC is proposed for the effective power analysis.

  • PDF

The Concept Design of Joint Part Between Propellant Tank and Feeding Line for Launch Vehicle (발사체 추진제 탱크와 배관 연결부 개념설계)

  • Jung, Dong-Ho;Cho, Kie-Joo;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.801-804
    • /
    • 2011
  • The concept design of joint part between propellant tank and feeding line for launch vehicle has been performed with the case study of oversea launch vehicles. we carried out, for the several configurations, numerical flow analyses to find the joint configuration which promises high flow uniformity at the outlet. There were a little difference in the numerical results, because the length of feeding lines are sufficiently long to stabilize the flow field.

  • PDF

Contigency Ranking Technique Using Line Capacity Calculation Method (선로용량 산정법을 이용한 상정사고 선택)

  • Park, Kyu-Hong;Jung, Jai-Kil;Hyun, Seung-Bum;Lee, In-Yong;Jung, In-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.285-288
    • /
    • 2000
  • This paper presents a technique for contingency ranting using line capacity calculation method and outage distribution factors(LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranting, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. ( $Z_r$/ $Z_s$=1) The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

Contigency Ranking Technique Using New Line Capacity (새로운 선로용량을 고려한 전력계통의 상정사고 선택)

  • Park, Kyu-Hong;Cho, Yang-Haeng
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

The Development of New UPFG Steady-State Model using Transmission Line Constant G. B (UPFC가 계통에 미치는 영향을 선로정수 G, B의 함수로 표현한 새로운 UPFC 정태 해석모델 개발)

  • Jeon, D.H.;Kim, T.G.;Chu, J.B.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1167-1169
    • /
    • 1999
  • This paper presents the new unified power flow controller(UPFC) load flow algorithm using UPFC transmission line constant model. The UPFC transmission line constant model represents a function of transmission line constant(G.B) UPFC's effect in power system. It can easily be incorporated in a load flow program. The algorithm is suited for monitoring the power system state as well as determining the magnitude and Phase angle of UPFC serial voltage source.

  • PDF

A study on fuzzy constraint line clustering for optical flow estimation (Optical Flow 추정을 위한 Fuzzy constraint Line Clustering에 관한 연구)

  • 김현주;강해석;이상홍;김문현
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.9
    • /
    • pp.150-158
    • /
    • 1994
  • In this paepr, Fuzzy Constraint Line Clustering (FCLC) method for optical flow estimation is proposed. FCLC represents the spatical and temporal gradients as fuzzy sets. Based on these sets, several constraint lines with different membership values are generated for the poxed whose velocity is to be estimated. We describe the process for obtaining the membership values of the spatial and temporal gradients and that of the corresponding constraint line. We also show the process for deciding the tightest cluster of point formalated by intersection between constraint lines. For the synthetic and real images, the results of FCLC are compared with of CLC.

  • PDF

Fast Contingency Ranking Algorithm of Power Equipment (전력설비의 신속한 상정사고 선택 앨고리즘)

  • 박규홍;정재길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 1998
  • This paper presents an algorithm for contingency ranking using line outage distribution factors(LODF) which are established by generation shift distribution factors(GSDF) from DC load flow solutions. By using the LODF, the line flow can be calculated according to the modification of base load flow if the contingency occur. To obtain faster contingency ranking, only the loading line more than 35[%](60[%] at 154[kV]) is included in the computation of Performance Index(PI). The proposed algorithm has been validated in tests on a 6-bus test system.system.

  • PDF

Job Route Selection Expert System for Workload Balancing in Flexible Flow Line (유연생산라인의 부하평준화를 위한 작업흐름선택 전문가시스템)

  • 함호상;한성배
    • Journal of Intelligence and Information Systems
    • /
    • v.2 no.1
    • /
    • pp.93-107
    • /
    • 1996
  • A flexible flow line(FFL) consists of several groups of identical machines. All work-orders flow along the same path through successive machine groups. Thus, we emphasized the balancing of workloads between machine groups in order to maximize total productivity. On the other hand, many different types of work-orders, in varying batch or lot sizes, are produced simultaneously. The mix of work-orders, their lot sizes, and the sequence in which they are produced affect the amount of workload. However, the work-orders and their lot sizes are prefixed and cannot be changed. Because of these reasons, we have developed an optimal route selection model using heuristic search and Min-Max algorithm for balancing the workload between machine groups in the FFL.

  • PDF

Reduction of Birefringence and Weld-Line using Over-Flow in Injection Compression Molding for Optic Lens (광학렌즈의 사출압축성형에서 오버플로우를 이용한 웰드라인과 복굴절 저감)

  • Kong, Ki-Hwan;Lee, Jin-Hyo;Kang, Byung-Ook;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.95-100
    • /
    • 2018
  • This study has focused on the weld-line and birefringence reduction of a plastic optic lens using over and CAE analysis in injection compression molding. A concave lens, which has a thin thickness in the center and a large difference in thickness between the center and the periphery, often causes weld-line defects during injection molding. CAE analysis has been applied to optimize the overflow design in order to reduce the weld-line defects and the polarization defects. To reduce the weld line and birefringence defects, overflow design and application using CAE analysis show that the measured birefringence values of the specimens before the overflow application were 46.8nm and 36.9nm, and the values after the over-flow application were 13.6nm and 14.0nm. From the experimental results, it is confirmed that birefringence is greatly improved when overflow is applied.