• 제목/요약/키워드: Flow limitation

검색결과 373건 처리시간 0.023초

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

삼각단면 극소히트파이프의 작동특성에 관한 기초 연구 (Fundamental study on performance characteristics of a micro heat pipe with triangular cross section)

  • 문석환;김종오;김철주
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

  • Wan, Jie;Sun, Wan;Deng, Jian;Pan, Liang-ming;Ding, Shu-hua
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1821-1833
    • /
    • 2021
  • The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

Mapping of Carbon Flow Distribution in the Central Metabolic Pathways of Clostridium cellulolyticum: Direct Comparison of Bacterial Metabolism with a Soluble versus an Insoluble Carbon Source

  • DESVAUX, MICKAEL,
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1200-1210
    • /
    • 2004
  • Metabolic flux analysis was established by adapting previous stoichiometric model developed during growth with cellulose to cell grown with cellobiose for further direct comparison of the bacterial metabolism. In carbon limitation with cellobiose, a shift from acetate-ethanol fermentation to ethanol-lactate fermentation is observed and the pyruvate overflow is much higher than with cellulose. In nitrogen limitation with cellobiose, the cellodextrin and exopolysaccharide overflows are much higher than on cellulose. In carbon and nitrogen saturation with cellobiose, the cellodextrin, exopolysaccharide, and free amino acids overflows reach the highest levels observed but all remain limited on cellulose. By completely shunting the cellulosome, the use of cellobiose allows to reach much higher carbon consumption rates which, in return, highlights the metabolic limitation of C. cellulolyticum. Therefore, the physical nature of the carbon source has a profound impact on the metabolism of C. cellulolyticum and most probably of other cellulolytic bacteria. For cellulolytic bacteria, the use of soluble carbon substrate must carefully be taken into consideration for the interpretation of results. Direct comparison of metabolic flux analysis from cellobiose and cellulose revealed the importance of cellulosome, phosphoglucomutase and pyruvate-ferredoxin oxidoreductase in the distribution of carbon flow in the central metabolism. In the light of these findings, future directions for improvement of cellulose catabolism by this bacterium are discussed.

Mitigation of Flooding under Externally Imposed Oscillatory Gas Flow

  • Lee, Jae-Young;Chang, Jen-Shih
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.475-479
    • /
    • 1995
  • During the hypothetical loss of coolant accident in the nuclear power plant the emergency core cooling water could not penetrate to the reactor core when the steam flow rate from the reactor core exceeds CCFL (Countercurrent flow limitation). The CCFL generated by earlier investigators are developed under the steady gas flow. However the flow instability in the reactor loop could generate oscillatory steam flow, hence their applicability under oscillating flow should be investigated. In this work, an experimental investigation of countercurrent flow in the vertical flow channel has been conducted under oscillatory gas flow. Pulsation of gas under oscillatory flow disturbs the flow pattern significantly and prevents flooding (CCFL) when its minimum value is less than the threshold gas flow rate value.

  • PDF

쌍곡선형 이상유동 방정식과 경계면 모양함수를 이용한 유체기계의 역류유동제한점 예측방법 개발 (Counter-Current Flow Limitation Model Based on the Hyperbolic Two-fluid Equations and Interface Shape Function)

  • 정지환
    • 한국산학기술학회논문지
    • /
    • 제1권1호
    • /
    • pp.15-22
    • /
    • 2000
  • 다상유체의 작동에 의해서 그 기능을 수행하는 산업기계는 매우 광범위하게 이용된다. 이들 중 일부는 서로 분리된 2상 유체가 반대방향으로 흐르는 특성을 이용하고 있다. 서로 반대방향으로 흐르는 액체상과 기체상의 최대 유량은 역류유동제한 현상으로 제한된다. 이상유동의 질량 및 운동량 보존 방정식을 세우고 쌍곡선형 방정식이 시스템의 특성방정식으로부터 역류유동제한 현상을 예측할 수 있는 모델을 개발하였다. 현재의 모델은 액체상 유입부의 기하학적 모양이 수직이거나 이와 유사한 형태로 되어 있어서 주변에 비등류가 형성되는 경우에 적용된다. 이 모델은 액체와 기체 사이의 질량전달을 일으키는 기계에 대한 유체역학적 운전제한 조건으로 이용될 수 있다.

  • PDF

흡기3밸브 실린더 헤드의 흡입 정상유동 특성에 관한 연구 (A Study on the Steady Intake Flow Characteristics of the Intake 3-Valve Cylinder Head)

  • 정재우;이기형;김우태
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.880-885
    • /
    • 2000
  • Flow patterns and steady flow characteristics of an intake 3valve cylinder head are not obviously declared. Thus, in the study, the characteristics and limitation of intake flow coefficient which applied to multi intake valve engine are introduced. The flow coefficient and tumble characteristics are investigated by means of the steady flow test and flow visualization method. As the results, it is found that the intake flow rate is dominated by effective valve open area. In addition, this paper shows that the mass flow rate of intake 3valve engine is greater than that of intake 2valve engine and tumble flow of intake 3valve engine is superior to that of intake 2valve engine.

베타 프라임 이론에 의한 저유량 필터의 성능 평가 (Filtration Performance Evaluation of Low Flow Rate Filters by Beta Prime Theory)

  • Lee, Jae-Cheon
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.115-121
    • /
    • 2000
  • The contaminant seperation performance of fitters has been widely investigated for many years. However, most of the proposed filter assessment techniques have proven disappointing for practical use. Although the Multipass (Beta) Filtration test method (ISO 4572) provides valuable information in assessing fi ters, it has a limitation on evaluating the increasing family of low-flow and high Beta filters. The limitation stems from two main sources: the over simplified theoretical model and the inherently complicated procedure in analysis of data. Hence a new advanced filtration theory, the Beta Prime developed on a draw-down test basis is applied to predict field operating characteristics of a filter for tractor hydraulic systems in this study.

  • PDF

Operation Limit of Flow Control for a Bistable Fluidic Valve

  • Lee, Ji Ung;Hong, Ji-Seok;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.389-394
    • /
    • 2017
  • The limitation of flow control for a bistable fluidic valve has been investigated. The physical model of the fluidic valve includes two main flow outlets and two control flow inlets. The experiments were conducted with pressure regulators, mass flow meters, and piezo sensors to analyze flow switching characteristics of the fluidic valve. The experimental data such as pressure and mass flow rate of control flows and the switching time of the main flow was obtained with various operating conditions. The operation limit of the fluidic valve is identified, and a model equation for pre-estimating the minimum control pressure to switch the direction of the main flow has been proposed.

육불화황 기체의 주입단계에 따른 탄소코일 기하구조의 제약 (Effect of Injection Stage of SF6 Gas Incorporation on the Limitation of Carbon Coils Geometries)

  • 김성훈
    • 한국진공학회지
    • /
    • 제20권5호
    • /
    • pp.374-380
    • /
    • 2011
  • 니켈촉매 막을 증착시킨 산화규산 기판위에 아세틸렌기체와 수소기체를 원료로 육불화황기체를 첨가기체로 탄소코일을 증착하였다. 육불화황이 투입되는 단계에 따라 성장된 탄소코일의 특성(형성 밀도, 형상)을 조사하였다. 육불화황을 연속적으로 주입하였을 경우 선형, 마이크로크기 코일, 나노크기 코일, 그리고 파동형 나노크기 코일 등 다양한 형태의 탄소코일들이 성장하였다. 하지만, 탄소코일 초기 증착단계에서 1분정도의 짧은시간 동안 육불화황을 주입한 경우 나노크기의 탄소코일 형상만을 대부분 얻을 수 있었다. 탄소코일 합성반응시간이 1분 정도 지체된 후의 단계에서 짧은시간 동안의 육불화황 주입은 코일형상 제어를 저해하였다. 따라서, 육불화황의 주입 시간과 주입단계가 탄소 코일의 형상을 결정하는 중요한 요인임을 알 수 있었다.