• 제목/요약/키워드: Flow length adjustment

검색결과 9건 처리시간 0.025초

온돌 난방분배기의 개도조정 (Adjustment of Valve Opening in Ondol Hot Water Distributor)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

고정밀 플라스틱 제품 성형을 위한 다수 캐비티 사출금형 및 성형 요소기술에 관한 연구 (A study on multi-cavity injection mold and molding elemental technology for plastic product of high precision tolerance)

  • 손종인;김철기;송병욱
    • Design & Manufacturing
    • /
    • 제17권4호
    • /
    • pp.57-62
    • /
    • 2023
  • As a representative method for mass production, a multi-cavity type mold capable of simultaneously molding products of the same shape can be applied. It has the advantage of improving the productivity from several times to several tens of times, but it may cause disadvantages which is the quality deviation with each cavity. This study, therefore, has tried to increase the cavity filling balance by using a melt flipper and a flow distance control part in the runner part of the mold. Along with this, the design and manufacturing of air vents during injection molding have been verified through experimental methods to achieve a higher level of multi-cavity filling balance and dimensional accuracy.

Bay길이에 따른 좌회전 용량산정에 관한 연구 (A study on Left turn Capacity by Bay Length)

  • 김정례;김기혁
    • 대한교통학회지
    • /
    • 제20권3호
    • /
    • pp.31-39
    • /
    • 2002
  • 본 연구는 신호교차로의 좌회전 용량을 파악하기 위하여 bay차로를 포함한 좌회전 이동류의 용량산정 모형을 개발하는데 목적이 있다. 본 연구에서는 신호교차로의 혼잡을 완화시키기 위해 설치 운용되고 있는 좌회전 bay 차로의 용량을 파악하여 보다 정확한 용량산정치 적용을 통한 교차로 운영의 분석자료를 제시하고자 한다. 연구방법은 좌회전 bay길이를 20∼120m까지 변화시키며, bay차로와 전용차로에 대한 차두시간을 분석하였다. Bay차로의 용량산정을 위해 차두시간과 차량유출행태 특성에 따라 1구간(출발손실구간:SLP), 2구간(포화차두구간:SFP), 3구간(차로선택구간:LSP)으로 구분하여 분석하였다. 수집된 차두시간 자료로 차량 대기위치순서별로 분석하였다 자료의 통계적 검증을 통하여 구간대별 평균차두시간을 설정한 후, bay길이별 용량산정 모형을 도출하였으며, 이를 이용하여 bay길이별 좌회전 용량을 산출하였다.

선박용 강제통풍 팬의 기어식 베인댐퍼 성능평가 (Development of Gear-Type Vane Dampers to Replace Link-Type Vane Dampers in Marine FD Fans)

  • 허남수;장성철;이경준
    • 한국산업융합학회 논문집
    • /
    • 제19권4호
    • /
    • pp.216-222
    • /
    • 2016
  • Thus, this study aimed to develop a gear-type vane damper in order to replace the link-type vane damper. To achieve this goal, the torque generated in a gear-type vane damper was analyzed, and a structural analysis was conducted. In addition, the fluid flow was analyzed according to the changes in the vane's angle, and experimental tests such as a dry-heat test and cold test were conducted considering the operating conditions of the vessels. Moreover, an appropriate actuator was selected for the developed gear-type vane damper, and studies on the reduction in the backlash due to the facing-pressure adjustment length and flow rate and leakage test due to the vane's angle were conducted.

지하수위 변화에 따른 지하공동 주변의 지하수 유동특성 해석 (Groundwater Flow Characterization in the Vicinity of the Underground Caverns by Groundwater Level Changes)

  • 강재기;양형식;김경수;김천수
    • 터널과지하공간
    • /
    • 제13권6호
    • /
    • pp.465-475
    • /
    • 2003
  • 본 논문은 지하공동이 건설되는 지역을 대상으로 공동내 지하수 유입량을 계산하기 위하여 영국의 AEA Technology에서 개발한 NAPSAC과 NAMMU를 이용하여 수치 모델링을 실시하였다. 이것은 3차원의 파쇄된 매질에서 지하수 유동에 대하여 아주 유효한 유한요소 소프트웨어 패키지이다. 모델링에 사용된 입력자료는 지표조사, 시추조사, 단일공 수리시험 자료 등을 이용하여 산출하였다. 공동내 지하수 유입량을 보다 정확히 산출하기 위하여 이방성 수리전도도를 고려하였으며 이방성 수리전도도값은 연구지역에 분포하는 균열체계의 확률적 분포특성이 반영된 균열망에서 역산되었다. 연속체 개념의 수치모델링을 통하여 평수기, 갈수기와 풍수기시의 지하 공동내 유입량, 유동시간, 유동경로의 변화를 계산하였다.

소유역구분이 SWAT 예측치에 미치는 영향 평가 (Effects of Subwatershed Delineation on SWAT Estimation)

  • 허성구;김기성;안재훈;임경재;최중대
    • 한국관개배수논문집
    • /
    • 제13권2호
    • /
    • pp.262-273
    • /
    • 2006
  • The Soil and Water Assessment Tool (SWAT) model has been widely used in hydrology and sediment simulation worldwide. In most cases, the SWAT model is first calibrated with adjustments in model parameters, and then the validation is performed. However, very little study regarding the effects on SWAT estimation of subwatershed delineation was performed. Thus, the SWAT model was applied to the Doam-dam watershed with various threshold values in subwatershed delineation in this study to examine the effects on the number of subwatershed delineated on SWAT estimation. It was found the flow effect of subwatershed delineation is negligible. However there were huge variations in SWAT estimated sediment, T-N, and T-P values with the use of various threshold value in watershed delineation. Sometimes these variations due to watershed delineation are beyond the effects of parameter adjustment in model calibration and validation. The SWAT is a semi-distributed modeling system, thus, the subwatershed characteristics are assumed to be the same for all Hydrologic Response Unit (HRU) within that subwatershed. This assumption leads to variations in the SWAT estimated sediment and nutrient output values. Therefore, it is strongly recommended the SWAT users need to use the HUR specific slope length and slope value in model runs, instead of using the slope and the corresponding slope length of the subawatershed to exclude the effects of the number of subwatershed delineated on the SWAT estimation.

  • PDF

열교환기 관사이의 거리변화에 대한 열효율 특성 (Characteristics of Thermal Efficiency with Changing Distances Between Tubes for Heat Exchanger)

  • 김종민;이재박;이승로;이창언;금성민
    • 에너지공학
    • /
    • 제19권3호
    • /
    • pp.177-181
    • /
    • 2010
  • 열교환기는 용도에 따라 여러가지 형태가 존재하지만 중요한 것은 열교환기의 성능을 향상시킴으로서 열교환기의 크기를 소형화하는 것이라 할 수 있다. 그러나 보일러처럼 열교환기가 버너 앞에 위치할 경우 열교환기의 효율도 중요하지만 환경오염물질의 배출특성도 고려되어야 한다. 따라서 본 연구에서는 비예혼합화염보다 화염길이가 짧고 당량비 조절을 통해 $NO_x$ 및 CO 배출을 제어할 수 있는 예혼합방식의 버너 앞에 원형관 열교환기를 설치한 후 열교환기 관사이의 거리 및 당량비를 변화시킬 때 $NO_x$와 CO의 배출특성과 열교환기의 열효율을 실험적으로 구하였다.

도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구 (Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel)

  • 유지오;김진수;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.68-74
    • /
    • 2016
  • 도로터널에 적용하는 반횡류환기방식은 터널의 전연장에 걸쳐서 단위길이당 풍량이 균일하게 될 수 있도록 포트의 개도 조정이 필수적이다. 그러나 현재 국내에서 운영중인 터널의 경우에는 설계시 이에 대한 고려가 적절히 이루어지지 못하고 있는 실정이다. 이에 본 연구에서는 개도계산을 위한 프로그램을 개발하고 반횡류환기방식의 터널에서 포트의 운영방안을 제시하였다. 연구결과, 포트의 개도는 급기방식의 덕트에서는 환기소측에서 덕트의 말단(bulk head)쪽으로 갈수록 증가하였다가 감소하는 경향을 가지며, 최소 개도는 56% 정도로 나타나고 있다. 또한 배기방식에서는 환기소측이 15% 정도로 가장 작고 bulk head 쪽으로 갈수록 증가하는 경향을 보이고 있다. 화재시 300 m 구간의 배연풍량을 검토한 결과, 포트사이즈를 조정하지 않는 경우와 급기방식으로 포트사이즈을 조정한 경우에는 터널중앙부의 배연량이 각각 8.1%와 12.5%로 터널중앙부의 배연풍량이 저조한 것으로 나타났다. 따라서 반횡류환기방식의 터널에서는 평상시 환기효율이 저하하더라도 배연시 균일한 풍량을 얻을 수 있도록 포트의 개도를 설정하여 운영하는 것이 반드시 필요한 것으로 판단된다.

Evaluation of multi-lane transverse reduction factor under random vehicle load

  • Yang, Xiaoyan;Gong, Jinxin;Xu, Bohan;Zhu, Jichao
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.725-736
    • /
    • 2017
  • This paper presents the two-, three-, and four-lane transverse reduction factor based on FEA method, probability theory, and the recently actual traffic flow data. A total of 72 composite girder bridges with various spans, number of lanes, loading mode, and bridge type are analyzed with time-varying static load FEA method by ANSYS, and the probability models of vehicle load effects at arbitrary-time point are developed. Based on these probability models, in accordance to the principle of the same exceeding probability, the multi-lane transverse reduction factor of these composite girder bridges and the relationship between the multi-lane transverse reduction factor and the span of bridge are determined. Finally, the multi-lane transverse reduction factor obtained is compared with those from AASHTO LRFD, BS5400, JTG D60 or Eurocode. The results show that the vehicle load effect at arbitrary-time point follows lognormal distribution. The two-, three-, and four-lane transverse reduction factors calculated by using FEA method and probability respectively range between 0.781 and 1.027, 0.616 and 0.795, 0.468 and 0.645. Furthermore, a correlation between the FEA and AASHTO LRFD, BS5400, JTG D60 or Eurocode transverse reduction factors is made for composite girder bridges. For the two-, three-, and four-lane bridge cases, the Eurocode code underestimated the FEA transverse reduction factors by 27%, 25% and 13%, respectively. This underestimation is more pronounced in short-span bridges. The AASHTO LRFD, BS5400 and JTG D60 codes overestimated the FEA transverse reduction factors. The FEA results highlight the importance of considering span length in determining the multi-lane transverse reduction factors when designing two-lane or more composite girder bridges. This paper will assist bridge engineers in quantifying the adjustment factors used in analyzing and designing multi-lane composite girder bridges.