• 제목/요약/키워드: Flow imaging

검색결과 545건 처리시간 0.028초

Identification of venular capillary remodelling: a possible link to the development of periodontitis?

  • Townsend, David
    • Journal of Periodontal and Implant Science
    • /
    • 제52권1호
    • /
    • pp.65-76
    • /
    • 2022
  • Purpose: The present study measured changes in arteriolar and venular capillary flow and structure in the gingival tissues during the development of plaque-induced gingival inflammation by combining dynamic optical coherence tomography (OCT), laser perfusion, and capillaroscopic video imaging. Methods: Gingival inflammation was induced in 21 healthy volunteers over a 3-week period. Gingival blood flow and capillary morphology were measured by dynamic OCT, laser perfusion imaging, and capillaroscopy, including a baseline assessment of capillary glycocalyx thickness. Venular capillary flow was estimated by analysis of the perfusion images and mean blood velocity/acceleration in the capillaroscopic images. Readings were recorded at baseline and weekly over the 3 weeks of plaque accumulation and 2 weeks after brushing was resumed. Results: Perfusion imaging demonstrated a significant reduction of gingival blood flow after 1 and 2 weeks of plaque accumulation (P<0.05), but by 3 weeks of plaque accumulation there was a more mixed picture, with reduced flow in some participants and increased flow in others. Participants with reduced flux at 3 weeks also demonstrated venular-type flow as determined by perfusion images and evidence of the development of venular capillaries as assessed by the velocity/acceleration ratio in capillaroscopic images. After brushing resumed, these venular capillaries were broken down and replaced by arteriolar capillaries. Conclusions: After 3 weeks of plaque accumulation, there was wide variation in microvascular reactions between the participants. Reduced capillary flow was associated with the development of venular capillaries in some individuals. This is noteworthy, as an early increase in venous capillaries is a key vascular feature of cardiovascular disease, psoriasis, Sjögren syndrome, and rheumatoid arthritis-diseases with a significant association with the development of severe gingival inflammation, which leads to periodontitis. Future investigations of microvascular changes in gingival inflammation might benefit from accurate capillary flow velocity measurements to assess the development of venular capillaries.

Associations Between Mammography and Ultrasound Imaging Features and Molecular Characteristics of Triple-negative Breast Cancer

  • Li, Bo;Zhao, Xin;Dai, Shao-Chun;Cheng, Wen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3555-3559
    • /
    • 2014
  • Background: The triple-negative breast cancer (TNBC) is an aggressive cancer characterized by the absence of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2). Preoperative mammography and ultrasound features of TNBC may potentially suggest characteristics of the disease and assist in treatment decisions. Materials and Methods: The study covered 153 patients with TNBC from May 2011 to May 2012 who were confirmed by postoperative pathology results in our hospital. We compared the radiological findings among the patients and sought to determine the significant iconographic features. The biomarkers p53 and Ki-67 are regarded as significant factors in TNBC. They were therefore used to divide the TNBC into four groups for assessment of relationships with TNBC imaging features. Results: On mammography, most TNBCs exhibit obscure (44.3%) masses. On ultrasound, the majority of masses (95.4%) were predominantly indistinct (50.7%), irregular (76.0%) or featuring posterior echo enhancement/shadowing. Color Doppler flow imaging (CDFI) emphasized hypervascular (32.9%) masses. Differences in CDFI by ultrasound among the four groups were statistically significant (p=0.009). There were obvious differences in the percentages of spiculated margin (p=0.049) and intensive posterior echo (p=0.006) with spotty flow imaging by ultrasound between the Ki-67 (+) p53 (+) and other groups. Conclusions: A combination of mammography and ultrasound revealed the imaging characteristics of TNBC included an obscure mass with less attenuated posterior echoes and some vascularity. A worse prognosis was associated with spiculated margin and intensive posterior echoes with spotty flow imaging.

MRI with Continuously Flowing Laser-Polarized $^3He$

  • Lee, Hyeong-Ju;Kim, Chul;Kim, Byung-Soo;Kim, Do-Hun;Lee, Hee-Cheon
    • 한국자기공명학회논문지
    • /
    • 제7권1호
    • /
    • pp.62-67
    • /
    • 2003
  • MRI of laser-polarized $^{129}$ Xe under continuous flow conditions has recently been used for imaging of porous materials, however, any attempts at using a continuously circulating flow of laser-polarized $^3$He have not been made until now, presumably due to its extremely long spin exchange time (5-10 hrs). Since the inherent NMR sensitivity of $^3$He is 80 times greater than that of $^{129}$ Xe when considering the natural abundance, $^3$He can be expected to be a better nucleus for imaging than $^{129}$ Xe even under continuous flow conditions. In this report, the first MRI with continuously flowing laser-polarized $^3$He is shown for a phantom of Teflon tubing, demonstrating the feasibility of $^3$He imaging under continuous flow.

  • PDF

세포 이미징 기능을 겸비한 생체 유세포 분석기 (In vivo Imaging Flow Cytometer)

  • 이호
    • 한국가시화정보학회지
    • /
    • 제5권1호
    • /
    • pp.9-11
    • /
    • 2007
  • 유(流)세포분석기(flow cytometer)는 일정한 체적 내에 존재하는 세포의 종류 및 개체 수 등을 계측하는 장비로써 생체에서 추출한 유액상태(혈액 또는 림프액)의 세포를 모세관(micro-channel)을 통과시킬 때 발생하는 산란 및 형광 빛을 이용하여 계측한다. 유세포 분석기는 신약의 투석 후 세포수의 증감, 암세포의 전이 및 세포주기의 분석 등을 연구하는 데 사용되며 현재 Becton-Dickinson's 등에서 상용화된 제품을 생산 판매하고 있으며, 계측을 위해서는 생체에서 세포를 추출해야 한다는 단점을 가지고 있다. Harvard 의과대학에서 최근에 개발한 생체 유세포분석기(In vivo Flow Cytometer)는 생체에서 세포를 추출하지 않고 세포의 수를 계측할 수 있다[1]. 레이저가 혈관의 특정한 부위에 조사되고 있고, 이곳을 세포가 통과하면서 발생하는 형광을 계측함으로써 주어진 시간 동안 특정세포군이 얼마나 지나가는 지를 계측할 수 있는 장비이다. 본 특별기사에서는 혈류 가시화 분야의 독자를 위해 최근에 "Optics Express"에 "In vivo imaging flow cytometer"라는 제목으로 최근에 개제된 논문의 내용을 하여 소개한다[2].

Special Issue for Biomedical Ultrasound: Towards Further Advances in Fundamentals and Applications by Comprehensive Reviews

  • Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.107-110
    • /
    • 2010
  • In this paper, the rationale and contents of the special issue of the Journal of the Acoustical Society of Korea regarding comprehensive reviews on past, present and future of biomedical ultrasound are described. Brief descriptions of invited articles are given, and efforts by all contributing authors are gratefully acknowledged.

Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography

  • Zhu Xiao Lin;Fan Zhou;U. Joseph Schoepf;Balakrishnan Pillai;Chang Sheng Zhou;Wei Quan;Xue Qin Bao;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.967-977
    • /
    • 2020
  • Objective: To evaluate the effects of tube voltage on image quality in coronary CT angiography (CCTA), the estimated radiation dose, and DNA double-strand breaks (DSBs) in peripheral blood lymphocytes to optimize the use of CCTA in the era of low radiation doses. Materials and Methods: This study included 240 patients who were divided into 2 groups according to the DNA DSB analysis methods, i.e., immunofluorescence microscopy and flow cytometry. Each group was subdivided into 4 subgroups: those receiving CCTA only with different tube voltages of 120, 100, 80, or 70 kVp. Objective and subjective image quality was evaluated by analysis of variance. Radiation dosages were also recorded and compared. Results: There was no significant difference in demographic characteristics between the 2 groups and 4 subgroups in each group (all p > 0.05). As tube voltage decreased, both image quality and radiation dose decreased gradually and significantly. After CCTA, γ-H2AX foci and mean fluorescence intensity in the 120-, 100-, 80-, and 70-kVp groups increased by 0.14, 0.09, 0.07, and 0.06 foci per cell and 21.26, 9.13, 8.10, and 7.13 (all p < 0.05), respectively. The increase in the DNA DSB level in the 120-kVp group was higher than those in the other 3 groups (all p < 0.05), while there was no significant difference in the DSBs levels among these latter groups (all p > 0.05). Conclusion: The 100-kVp tube voltage may be optimal for CCTA when weighing DNA DSBs against the estimated radiation dose and image quality, with further reductions in tube voltage being unnecessary for CCTA.

PIV(Particle Imaging Velocimetry)에 의한 음향류의 실시간 가시화 계측 (Real time measurement of an acoustic stream by a visualization technique, PIV)

  • 도덕희
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1998년도 학술발표대회 논문집 제17권 1호
    • /
    • pp.239-242
    • /
    • 1998
  • A new real time sound field visualization technique is introduced in this study using PIV(Particle Imaging Velocimetry) technique. Small particles of which density is small enough to follow up the air flow are used for sound visualization. When the driving frequency is in the vicinity of the resonance frequency of the simplified 2-dimensional muffler system, an acoustic streaming is shown and of which velocity distribution is obtained through PIV technique. It is experimentally proved that the present technique is able to visualize and quantify the sound field's energy flow.

  • PDF

Postcontrast T1-weighted Brain MR Imaging in Children: Comparison of Fat-suppressed Imaging with Conventional or Magnetization Transfer Imaging

  • 이충욱;구현우;최충곤
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.37-37
    • /
    • 2003
  • To assess the merits and demerits of postcontrast fat-suppressed (FS) brain MR imaging in children in the evaluation of various enhancing lesions, compared with postcontrast conventional or Magnetization Transfer (MT) imaging. 대상 및 방법: We reviewed patients with enhancing lesion on brain MR imaging who underwent both FS imaging and one of conventional or MT imaging as a postcontrast T1-weighted brain MR imaging. Inclusion criteria of our study were as follows: MR studies should be peformed within one-year interval and showed no significant interval change of imaging findings. Thirty-four patients (21 male, 13 female; mean age, 8 years) with 43 enhancing lesions (19 intra-axial, 19 extra-axial, and 5 orbital location) were included in this study, Twenty-one pairs of FS and conventional imaging, and 15 pairs of FS and MT imaging were available. Two radiologists visually assessed the lesion conspicuity and the presence of flow or susceptibility artifacts in a total of 36 pairs of MR imaging by consensus. For 21 measurable lesions (19 pairs of FS and conventional imaging, 5 pairs of FS and MR imaging), contrast ratio between the lesion and the normal brain( [SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared.

  • PDF

레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발 (Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue)

  • 이민철;등거인
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

PIV에 의한 냉장고 기류특성 평가방법 (A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV)

  • 김석로;도덕희;이재근;김경천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF