• Title/Summary/Keyword: Flow force

Search Result 2,355, Processing Time 0.035 seconds

Experimental study on flow characteristics for the high efficiency transporting of the dredged soil (준설토 이송고효율화를 위한 유동특성의 실험적 분석)

  • Kim, Yu-Seung;Lee, Myung-Han;Lee, Su-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2016
  • To evaluate the effects of magnetic force for transporting the dredged soil, magnetic energy inducing device was installed at the dredger. The whole length of transporting pipeline reaches more than 8.5km and the efficiency of the system and the characteristics of the flow are critical factors. The main parameters which govern the flow are flow-rate, velocity, concentration and slip-layer's condition, so in the field test monitoring system was applied to check the real time conditions of the closed circuit flow and the main parameters. From analyzing the relation between the dredged soil amounts and the pump power, it can be concluded that the magnetic forces effect on the transporting system, increase the transporting quantities of dredged soil and decrease power consumption of the pump.

A Numerical Study on the Heat Transfer Characteristics of Impinging Jet Flow in the Presence of Applied Magnetic Fields (자기장이 인가된 충돌제트의 열전달 특성에 관한 수치적 연구)

  • Lee Hyun Goo;Yoon Hyun Sik;Hong Seung Do;Ha Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.653-661
    • /
    • 2005
  • The present study numerically investigates two-dimensional fluid flow and heat transfer ir the confined jet flow in the presence of applied magnetic field. For the purpose of controlling vortex shedding and heat transfer, numerical simulations to calculate the fluid flow and heat transfer in the confined jet are performed for different Reynolds numbers in the absence and presence of magnetic fields and for different Prandtl numbers of 0.02 (liquid metal), 0.7 (air) and 7 (water) in the range of $0{\le}N{\le}0.05$, where N is the Stuart number (interaction parameter) which is the ratio of electromagnetic force to inertia force. The present study reports the detailed information of flow and thermal quantities in the channel at different Stuart numbers. As the intensity of applied magnetic fields increases, the vortex shedding formed in the channel becomes weaker and the oscillating amplitude of impinging jet decreases. The flow and thermal fields become the steady state if the Stuart number is greater than the critical value. Thus the Nusselt number at the stagnation point representing the heat transfer characteristics also vary as a function of Stuart number.

Numerical Simulation of Flow around Variable Pitch Helically Elliptic Twisted Cylinder based on the Biomimetic Flow Control (생체모방 유동제어 기반 가변 피치 나선형 실린더 주위 유동 해석)

  • Moon, Jahoon;Yoon, Hyun Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.2
    • /
    • pp.96-103
    • /
    • 2020
  • The new geometric disturbance is proposed to control the flow around the bluff body. The new geometry is characterized by the variable pitch which is applied on the Helically Elliptic Twisted (HET) cylinder. The performance of the HTE geometry as a biomimetic passive flow control was confirmed by Jung and Yoon (2014). The Large Eddy Simulation (LES) is used for the evaluation of the flow control performance of the Variable Pitch HTE (VPHTE) cylinder at Reynolds number (Re) of 3000 corresponding to the subcritical regime. The circular and HTE cylinders are also considered to compare the performance of the VPHTE cylinder at the same Re. The VPHTE cylinder gives the smallest values of the force coefficients than the circular and HTE cylinders. The drag and lift coefficients of the VPHTE cylinder are about 15.2% and 94.0% lower than those of the circular cylinder, respectively. Especially, the VPHTE cylinder achieves about 2.3% and 30.0% reduction of the drag coefficient and the root mean square of the lift coefficient than the HTE cylinder, respectively. Furthermore, The VPHTE cylinder forms more elongated and stabilized separated shear layer than the circular cylinder, which supports the reduction of the force coefficients.

Flow Analysis and Measurement of Pressure Distribution along Inclinde Circular Valve Reeds and Valve Seat Geometric Parameters of Reciprocating Compressor (왕복동형 압축기의 경사진 원판형 밸브리드와 밸브 시트의 기하학적 파라미터에 대한 압력분포 측정 및 유동해석)

  • Park, Jong-Ho;Yoon, Jong;Kim, Tae-Min;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.828-833
    • /
    • 2003
  • This work analyzes the effects of the independent variation of different geometric dimensions of compressor valves on the effective flow and force areas using a circular valve plate, such as different geometry of the valve seat, and the valve reed is opened and closed by pressure pulsation, the flow characteristic of the refrigerant passing the valve is very important. In the present study, a circular disk with inclination is assumed to be the valve reed of a reciprocating compressor and numerical analysis of three dimensional velocity fields are performed for theradial flow through the valve model. The effective flow and force area which are required to predict the efficiency of the valve are required to predict the efficiency of the valve are measured and compared with the numerical analysis in this research.

  • PDF

Control effects of the flow and the aerodynamic force around the downstream cylinder by a spinning upstream cylinder in uniform flow (균일류의 회전원주 제어에 의한 유동 및 공력 제어효과에 관한 연구)

  • Bu, Jeong-Suk;Yang, Jong-Pil;Kim, Chang-Su;Sin, Yeong-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.346-359
    • /
    • 1998
  • The aerodynamic forces and wake structure of the non-rotating downstream circular cylinder, of which the uniform freestream flow is interfered with another spinning upstream cylinder having the same diameter that is located upstream in a line have been investigated experimentally. When the spin rate of the downstream cylinder defined as the ratio of tangential surface velocity of the spinning cylinder to the freestream velocity increases gradually from zero to 1.4, the change of surface pressure distribution, aerodynamic forces of the non-rotating downstream cylinder were measured in case of several distance ratios of 1.5, 3.0, and 4.5 defined as the ratio of distance between the centers of two cylinders to the diameter. The wake flow patterns behind the cylinder were also investigated in each case. From the present experiments, it has been found that the spin rate significantly influences the aerodynamic forces and near-wake flow phenomena of the downstream cylinder in such a way that the drag increases as the spin rate and distance ratio increase and the wake width increases as the distance ratio increases.

CALCULATION OF RADIAL FORCE IN CIRCULAR COILS USING dM/dr (dM/dr에 의한 원형코일의 Radial Force 계산)

  • Kim, Gi-Bung;Gwon, Byeong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.95-97
    • /
    • 1996
  • Circular coils are widely used in electromagnetic applications, and the force in a sets of coils consisting of more than two can be divided into three components. Among them, one component called radial force is acting on the radial axis, and it is exposed as stree or impact. Calculation of the radial force was used to be performed by introducing Ampear's law of force which is $F=J{\times}B$. However, many cases in analyzing a system, calculation method from the mutual inductance between the coils is oftenly employed to get the axial force and resulting dynamics. In this case, if the calculation of radial force from the mutual inductance is possible, flow of the calculation for the system analysis would be much more simpler.

  • PDF

Steady wind force coefficients of inclined stay cables with water rivulet and their application to aerodynamics

  • Matsumoto, Masaru;Yagi, Tomomi;Sakai, Seiichiro;Ohya, Jun;Okada, Takao
    • Wind and Structures
    • /
    • v.8 no.2
    • /
    • pp.107-120
    • /
    • 2005
  • The quasi-steady approaches to simulate the wind induced vibrations of inclined cables, especially on the rain-wind induced vibration, have been tried by many researchers. However, the steady wind force coefficients used in those methods include only the effects of water rivulet, but not the axial flow effects. The problem is the direct application of the conventional techniques to the inclined cable aerodynamics. Therefore, in this study, the method to implement the axial flow effects in the quasi-steady theory is considered and its applicability to the inclined cable aerodynamics is investigated. Then, it becomes clear that the perforated splitter plate in the wake of non-yawed circular cylinder can include the effects of axial flow in the steady wind force coefficients for inclined cables to a certain extent. Using the lateral force coefficients measured in this study, the quasi-steady theory may explain the wind induced instabilities of the inclined cables only in the relatively high reduced wind velocity region. When the Scruton number is less than around 40, the high speed vortex-induced vibration occurs around the onset wind velocity region of the galloping, and then, the quasi-steady approach cannot be applied for estimating the response of wind-induced vibration of inclined cable.

A Study on Slip Behavior of Fiber Preform by High Speed Resin Flow in High Pressure Resin Transfer Molding (고압 RTM 공정에서 고속 수지 유동에 의한 섬유 보강재의 변형 거동에 관한 연구)

  • Ahn, Jong-Moo;Seong, Dong-Gi;Lee, Won-Oh;Um, Moon-Kwang;Choi, Jin-Ho
    • Composites Research
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • This paper presents the slip behavior of composite fabrics by high speed resin flow in high pressure resin transfer molding. In order to observe the fiber deformation behavior, we constructed the measuring equipment for friction coefficient between fiber and mold, and the monitoring system for deformation of fiber preform in high-pressure RTM process. Coulomb friction coefficient and hydrodynamic friction coefficient between fiber preform and mold were measured and the external force induced by fluid flow causing the deformation of fiber preform was measured. Friction force calculated by friction coefficient and the external force upon fiber deformation were compared, which showed that preform deformation occurred when the external force was bigger than the friction force. The slip behavior of the fiber preform was mainly influenced by the volume fraction of fiber preform and the friction coefficient.

Incipient motion criteria of uniform gravel bed under falling spheres in open channel flow

  • Khe, Sok An;Park, Sang Deog;Jeon, Woo Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.149-149
    • /
    • 2018
  • Prediction on initial motion of sediment is crucial to evaluate sediment transport and channel stability. The condition of incipient movement of sediment is characterized by bed shear stress, which is generated from force of moving water against the bed of the channel, and by critical shear stress, which depends on force resisting motion of sediment due to the submerged weight of the grains. When the bed shear stress exceeds the critical shear stress, sediment particles begin rolling and sliding at isolated and random locations. In Mountain River, debris flow frequently occurs due to heavy rainfall and can lead some natural stones from mountain slope into the bed river. This phenomenon could add additional forces to sediment transport system in the bed of river and also affect or change direction and magnitude of sediment movement. In this paper, evaluations on incipient motion of uniform coarse gravel under falling spheres impacts using small scale flume channel were conducted. The drag force of falling spheres due to water flow and length movement of falling spheres were investigated. The experiments were carried out in flume channel made by glass wall and steel floor with 12 m long, 0.6 m wide, and 0.6 m deep. The bed slopes were selected with the range from 0.7% to 1.5%. The thickness of granular layer was at least 3 times of diameter of granular particle to meet grain placement condition. The sphere diameters were chosen to be 4cm, 6 cm, 8 cm, 10 cm. The spheres were fallen in to the bed channel for critical condition and under critical condition of motion particle. Based on the experimental results, the Shields curve of particles Reynold number and dimensionless critical shear stress were plotted. The relationship between with drag force and the length movement of spheres were plotted. The pathways of the bed material Under the impact of spheres falling were analyzed.

  • PDF

Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank (관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰)

  • Park, Kyoohong;Yu, Soonyu;Lee, Taehoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is $0.062m^2$(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.