• 제목/요약/키워드: Flow failure

검색결과 883건 처리시간 0.038초

Effects of Gap Resistance and Failure Location on prompt Fission Gas Release from a Cladding Breach

  • Tak, Nam-Il;Chun, Moon-Hyun;Ahn, Hee-Jin;Park, Jong-Kil;Rhee, In-Hyoung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.184-189
    • /
    • 1997
  • A prompt fission gas release model incorporating the resistance to gas flow in the gap was developed and the effects of gap resistance and failure location on prompt fission gas release from the cladding breach were assessed. The process of prompt fission gas release from the plenum and gap into the coolant was modeled in accordance with three major phenomena: (1) transient gas flow in the gap, (2) the growth of the fission gas bubble while it is still attached to the breach, and (3) the detachment of the fission gas bubble from the breach and mixing with the coolant. The cumulative mass release fraction by the present model was calculated for the case of Young-Gwang 3 & 4 nuclear fuel rod as a typical example. The results showed that the release behavior of prompt fission gas with time was different from the frictionless model which has frequently been used in a simplified approach, and that the location of cladding failure was another key factor for the prompt fission gas release process due to the resistance in the gap.

  • PDF

Numerical simulation of tensile failure of concrete using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab
    • Computers and Concrete
    • /
    • 제18권1호
    • /
    • pp.39-51
    • /
    • 2016
  • This paper considers the tensile strength of concrete samples in direct, CTT, modified tension, splitting and ring tests using both of the experimental tests and numerical simulation (particle flow code 2D). It determined that which one of indirect tensile strength is close to direct tensile strength. Initially calibration of PFC was undertaken with respect to the data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, validation of the simulated models in four introduced tests was also cross checked with the results from experimental tests. By using numerical testing, the failure process was visually observed and failure patterns were watched to be reasonable in accordance with experimental results. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Tensile strength of concrete in direct test was less than other tests results. Tensile strength resulted from modified tension test was close to direct test results. So modified tension test can be a proper test for determination of tensile strength of concrete in absence of direct test. Other advantages shown by modified tension tests are: (1) sample preparation is easy and (2) the use of a simple conventional compression press controlled by displacement compared with complicate device in other tests.

Identification of hydrogen flammability in steam generator compartment of OPR1000 using MELCOR and CFX codes

  • Jeon, Joongoo;Kim, Yeon Soo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1939-1950
    • /
    • 2019
  • The MELCOR code useful for a plant-specific hydrogen risk analysis has inevitable limitations in prediction of a turbulent flow of a hydrogen mixture. To investigate the accuracy of the hydrogen risk analysis by the MELCOR code, results for the turbulent gas behavior at pipe rupture accident were compared with CFX results which were verified by the American National Standard Institute (ANSI) model. The postulated accident scenario was selected to be surge line failure induced by station blackout of an Optimized Power Reactor 1000 MWe (OPR1000). When the surge line failure occurred, the flow out of the surgeline was strongly turbulent, from which the MELCOR code predicted that a substantial amount of hydrogen could be released. Nevertheless, the results indicated nonflammable mixtures owing to the high steam concentration released before the failure. On the other hand, the CFX code solving the three-dimensional fluid dynamics by incorporating the turbulence closure model predicted that the flammable area continuously existed at the jet interface even in the rising hydrogen mixtures. In conclusion, this study confirmed that the MELCOR code, which has limitations in turbulence analysis, could underestimate the existence of local combustible gas at pipe rupture accident. This clear comparison between two codes can contribute to establishing a guideline for computational hydrogen risk analysis.

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

반도체 웨이퍼 제조공정에서의 스케줄링 규칙들의 성능 분석 (Performance Analysis of Scheduling Rules in Semiconductor Wafer Fabrication)

  • 정봉주
    • 한국시뮬레이션학회논문지
    • /
    • 제8권3호
    • /
    • pp.49-66
    • /
    • 1999
  • Semiconductor wafer fabrication is known to be one of the most complex manufacturing processes due to process intricacy, random yields, product diversity, and rapid changing technologies. In this study we are concerned with the impact of lot release and dispatching policies on the performance of semiconductor wafer fabrication facilities. We consider several semiconductor wafer fabrication environments according to the machine failure types such as no failure, normal MTBF, bottleneck with low MTBF, high randomness, and high MTBF cases. Lot release rules to be considered are Deterministic, Poisson process, WR(Workload Regulation), SA(Starvation Avoidance), and Multi-SA. These rules are combined with several dispatching rules such as FIFO (First In First Out), SRPT (Shortest Remaining Processing Time), and NING/M(smallest Number In Next Queue per Machine). We applied the combined policies to each of semiconductor wafer fabrication environments. These policies are assessed in terms of throughput and flow time. Basically Weins fabrication setup was used to make the simulation models. The simulation parameters were obtained through the preliminary simulation experiments. The key results throughout the simulation experiments is that Multi-SA and SA are the most robust rules, which give mostly good performance for any wafer fabrication environments when used with any dispatching rules. The more important result is that for each of wafer fabrication environments there exist the best and worst choices of lot release and dispatching policies. For example, the Poisson release rule results in the least throughput and largest flow time without regard to failure types and dispatching rules.

  • PDF

AA5083 합금의 고온유동응력 및 연신율에 미치는 압연온도와 패스변형량의 영향 (The Effects of Pass Strain and Rolling Temperature on Flow Stress and Flow Strain of AA5083 Alloy)

  • 고병철;박도현;유연철
    • 소성∙가공
    • /
    • 제8권2호
    • /
    • pp.169-177
    • /
    • 1999
  • Different pass strains and rolling temperatures were applied to understand the effects of pass strain and rolling temperature on flow stress and flow strain of AA5083 alloy. The specimens were prepared by conventional casting process followed by hot rolling. Hot torsion tests were conducted at temperature ranges of 350 to 52$0^{\circ}C$ under a strain rate of 1.0/sec. During the process, hot-restoration mechanisms, dynamic recovery(DRV) or dynamic recrystallization (DRX), of the AA5083 alloy were analyzed from the flow curves and deformed microstructures. It was found that while the rolling strain per pass and rolling temperature have little effect on the folw stress, they have significant effect on the failure strain. The DRV was responsible for the hot restoration mechanism of the hot-rolled specimen. heavily elongated grains and small subgrains containing dislocations were obtaned during the hot deformation. This was due to the presence of Al6Mn precipitate in the alloy.

  • PDF

절리계 모사결과의 암반사면설계 적용 사례 (A Case Study on Joint System Simulation Results Application to Rock Slope Design)

  • 김동휘;정혁일;김석기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.669-680
    • /
    • 2005
  • It is very difficult to determine the failure block scale in great rock slopes. Especially, postulating entire slope domain as a failure block without attention to discontinuity trace lenth makes very confuse and difficult to design rock slopes. In this paper, we estimate realistic failure block scale using joint system simulation method and introduce the application procedures on rock slope analysis. Besides, presenting how joint characteristics measurement and statistical analysis results are applicated to slope stability analysis design flow.

  • PDF

Failure mechanisms in coupled poro-plastic medium

  • Hadzalic, Emina;Ibrahimbegovic, Adnan;Nikolic, Mijo
    • Coupled systems mechanics
    • /
    • 제7권1호
    • /
    • pp.43-59
    • /
    • 2018
  • The presence of the pore fluid strongly influences the reponse of the soil subjected to external loading and in many cases increases the risk of final failure. In this paper, we propose the use of a discrete beam lattice model with the aim to investigate the coupling effects of the solid and fluid phase on the response and failure mechanisms in the saturated soil. The discrete cohesive link lattice model used in this paper, is based on inelastic Timoshenko beam finite elements with enhanced kinematics in axial and transverse direction. The coupling equations for the soil-pore fluid interaction are derived from Terzaghi's principle of effective stresses, Biot's porous media theory and Darcy's law for fluid flow through porous media. The application of the model in soil mechanics is illustrated through several numerical simulations.

Pooling shrinkage estimator of reliability for exponential failure model using the sampling plan (n, C, T)

  • Al-Hemyari, Z.A.;Jehel, A.K.
    • International Journal of Reliability and Applications
    • /
    • 제12권1호
    • /
    • pp.61-77
    • /
    • 2011
  • One of the most important problems in the estimation of the parameter of the failure model, is the cost of experimental sampling units, which can be reduced by using any prior information available about ${\theta}$, and devising a two-stage pooling shrunken estimation procedure. We have proposed an estimator of the reliability function (R(t)) of the exponential model using two-stage time censored data when a prior value about the unknown parameter (${\theta}$) is available from the past. To compare the performance of the proposed estimator with the classical estimator, computer intensive calculations for bias, mean squared error, relative efficiency, expected sample size and percentage of the overall sample size saved expressions, were done for varying the constants involved in the proposed estimator (${\tilde{R}}$(t)).

  • PDF

연속 n중 k의 고장 연결 시스템에 있어서 최적 Redundancy 설계 (Optimal Redundancy of the Consecutive k out of n Failure Lines Included or Excluded Sink-Source Parts.)

  • Bok-Man, Kim;Chung-Hwan, Oh
    • 산업경영시스템학회지
    • /
    • 제17권30호
    • /
    • pp.209-214
    • /
    • 1994
  • A consecutive k out of n failure lines with sink-source parts is a system of components in sequence such that the system fails whether some k consecutive components are all fail. Some object, be it a flow, is to be relayed from a source to a sink through a sequence of intermediate stations(components). Now care should be taken as to if the source and the sink are also considered components of the systems, i. e. , whether they serve the same function as the intermediate components (stations). Such systems are different from ordinary consecutive k- out of n failure lines by adding the on source and sink pole[6]. The main properties of the reliability by the optimal redundancy of consecutive k out of n failure lines are presented under this modification.

  • PDF