• Title/Summary/Keyword: Flow deviation

Search Result 548, Processing Time 0.023 seconds

Tethered DNA shear dynamics in the flow gradient plane: application to double tethering

  • Lueth, Christopher A.;Shaqfeh, Eric S.G.
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.141-146
    • /
    • 2007
  • We examine the wall contact of a $3\;{\mu}m$ tethered DNA chain's free end under shear with a focus on developing schemes for double-tethering in the application of making scaffolds for molecular wires. At this scale our results are found to be highly dependent on small length scale rigidity. Chain-end-wall contact frequency, mean fractional extension deficit upon contact, and standard deviation in extension upon contact are examined for scaling with dimensionless flow strength, Wi. Predictions made using a one dimensional approximation to the Smoluchowski equation for a dumbbell and three dimensional dumbbell simulations produce extension deficit, standard deviation, and frequency scaling exponents of -1/3, -1/3, and 2/3, respectively whereas more fine-grained Kratky-Porod (KP) simulations produce scaling exponents of -0.48, -0.42, and 0.76. The contact frequency scaling of 2/3 is derived from the known results regarding cyclic dynamics Analytical scaling predictions are in agreement with those previously proposed for ${\lambda}-DNA$. [Ladoux and Doyle, 2000, Doyle et al., 2000]. Our results suggest that the differences between the dumbbell and the KP model are associated with the addition of chain discretization and the correct bending potential in the latter. These scaling results will aide future exploration in double tethering of DNA to a surface.

Development of a New Water Circulating System for Hot Water Mattress Without Water Pump (새로운 펌프 없는 온수매트용 온수 순환 시스템의 개발)

  • Je, Jong Joo;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1031-1036
    • /
    • 2013
  • The motor-driven water pump boiler for a water circulating mattress generates noise and vibration as it supplies a large water flow rate. A non-pump boiler can reduce such noise and vibration, however, the water circulation flow rate becomes lesser than that in motor-driven water pump boilers, and a large temperature deviation occurs between the inlet and the outlet of the mattress. In this research, a new non-pump boiler for water circulating mattress is developed and its performance is experimentally validated and compared with the existing non-pump boilers. The experimental results show that temperature response time is improved and temperature deviation is reduced.

Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel (수평 microchannel의 $CO_2$ 비등열전달)

  • Choi, Kwang-Il;Ardiyansyah, Ardiyansyah;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF

Flow Condensation Heat Transfer Coefficients of R22, R410A and Propane in Aluminum Multi-Channel Tube (알루미늄 다채널 평판관내 R22, R410A, Propane의 흐름 응축 열전달 성능 비교)

  • Park Ki-Jung;Lee Ki-Young;Jung Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.649-658
    • /
    • 2005
  • Flow condensation heat transfer coefficients (HTCs) of R22, R410, Propane (R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of $0.1\~0.9$ at mass flux of $200\~400kg/m^2s$ and heat flux of $7.3\~7.7kW/m^2$ at the saturation temperature of $40^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within $25\%$ deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than $20\%$ for all data.

Flow Condensation Heat Transfer Coefficients of R22 Alternative refrigerants in Aluminum Multi-Channel Tube (알루미늄 다채널 평판관내 R22 대체냉매의 흐름 응축 열전달 성능 비교)

  • Lee, Ki-Young;Lee, Min-Hang;Jung, Dong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.249-255
    • /
    • 2005
  • Flow condensation heat transfer coefficients(HTCs) of R22, R4IO, Propane(R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53 m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of 0.1 ${\sim}$ 0.9 at mass flux of $200{\sim}400$ $kg/m^2s$ and heat flux of $7.3{\sim}7.7$ $kW/m^2$ at the saturation temperature of $4^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within 25% deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than 20% for all data.

  • PDF

A Study on Extraction Method of Hazard Traffic Flow Segment (고속도로 위험 교통류 구간 추출 방안 연구)

  • Chong, Kyusoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.6
    • /
    • pp.47-54
    • /
    • 2021
  • The number of freeway traffic accidents in Korea is about 4,000 as of 2020, and deaths per traffic accident is about 3.7 times higher than other roads due to non-recurring congestion and high driving speed. Most of the accident types on freeways are side and rear-end collisions, and one of the main factors is hazard traffic flow caused by merge, diverge and accidents. Therefore, the hazard traffic flow, which appears in a continuous flow such as a freeway, can be said to be important information for the driver to prevent accidents. This study tried to classify hazard traffic flows, such as the speed change point and the section where the speed difference by lane, using individual vehicle information. The homogeneous segment of speed was classified using spatial separation based on geohash and space mean speed that can indicate the speed difference of individual vehicles within the same section and the speed deviation between vehicles. As a result, I could extract the diverging influence segment and the hazard traffic flow segment that can provide dangerous segments information of freeways.

Numerical Analysis of Flows on H-S and B-B Flow Surfaces in Axial-Flow Tubomachine (軸流터어보機械 의 H-S面 과 B-B面상 의 流動 의 數値解析)

  • 조강래
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.2
    • /
    • pp.153-160
    • /
    • 1983
  • The flows in an axial flow turbomachine are calculated numerically in the two sets of flow surfaces of H-S and B-B surfaces assuming that the flow is axisymmetric. The calculation is performed by regarding the governing equations as the quasi-Poisson's equations and using the finite element method for the flow regions divided into triangular elements. The results of numerical calculation agree comparatively well with the experimental results and it has been found that the distribution of an axial velocity component at the rotor exit is not necessarily uniform under the influences of the inlet guide vanes and the front shape of the hub even if the rotor is designed by the free-vortex theory. Also it has been found that the existence of the optimum value of the blade number can be estimated from the results of calculation of deviation angles at rotor exit if we consider the viscous flow-loss, and that the flows of B-B surfaces are affected very sensitively by the degree of satisfaction of Kutta condition.

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF

Flow Analysis for Design Modification of Marine Generator Fan (박용 발전기 냉각 팬 설계변경에 따른 유동해석)

  • Kim, Hong-Won;Seol, Sin-Su;Ha, Ji-Soo;Kim, Jin-O
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.840-844
    • /
    • 2003
  • A study for increase of fan flow rate by geometric modification has been conducted to decrease temperature rise of marine generator inner part. Through experiment of a real product, a performance curve for various flow resistances was obtained. Flow analyses for each cases were done by using commercial code-FLUENT and the results were very similar to experimental data (0.7% deviation at normal operating condition). Through flow analysis results for various design geometric modification, a scroll type fan was adopted as a best design geometry with 100Pa more pressure and 22% more flow rate than original fan.

  • PDF

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF