• Title/Summary/Keyword: Flow defect

검색결과 347건 처리시간 0.022초

좌우단락을 보인 심방중격결손, 심실중격결손 및 동맥관개존을 동반한 폐동맥판막협착증 -1례 보고- (Pulmonary valvular stenosis combined with atrial septal defect, ventricular septal defect and patent ductus arteriosus with left to right shunt: a case report)

  • 정황규
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.310-315
    • /
    • 1983
  • The combined anomaly of pulmonary stenosis with atrial or ventricular septal defects is usually associated with decreased pulmonary blood flow and right to left shunt, and result in generalized cyanosis. Non-cyanotic pulmonary stenosis patients have generally been considered to have isolated pulmonary stenosis with intact septa. We are going to report a case of pulmonary stenosis with septal defects who have no frank cyanosis at rest because of the predominant intracardiac shunt from left to right. Recently, we managed surgically a case of pulmonary valvular stenosis combined with secundum type atrial septal defect, type II ventricular septal defect, and patent ductus arteriosus. The clinical manifestations of this patient were exertional dyspnea, frequent upper respiratory infection, chest discomfortness and lethargy since late childhood and these had been progressively aggravated. Pulmonary valvular stenosis, atrial septal defect and ventricular septal defect were closed through simply right atriotomy and patent ductus arteriosus through pulmonary arteriotomy. Immediate postoperative course was uneventful and one year follow up is excellent.

  • PDF

드로우 금형의 에어포켓 유출 유동해석 (Flow Analysis of the Air Pocket in Draw Die)

  • 황세준;박원규;김철;오세욱;조남영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.345-348
    • /
    • 2006
  • In sheet metal forming process using press and draw die some defect can be made because of the high pressure of air pocket between draw die and the product. The purpose of this study is to develop a program to decide an optimal combination of air vent hole size and number to prevent those defect on product. The air inside air pocket is considered as ideal gas and the compression and expansion is assumed as isentropic process. The mass flow is computed in two flow condition: unchocked and chocked condition. The present computation obtains required cross-sectional area of air vent hole for not exceeding the user specified pressure such as the pressure for yielding strength of the product or the pressure for unchocked flow. To validate the program the present results are compared with the results of other researchers and commercial CFD code.

  • PDF

다상유체해석을 통한 기포결함 예측과 금형설계기술 (Study for Permanent Mold Design Technology and Porosity Defect Prediction Method by Multi-Phase Flow Numerical Simulations)

  • 최영심;조인성;황호영;최정길;홍준호
    • 소성∙가공
    • /
    • 제14권3호
    • /
    • pp.224-232
    • /
    • 2005
  • The high-pressure die-casting is one of the most effective methods to produce a large amount of products in short cycle time. This process, however, has a problem that the gas porosity defect appears easily. The generation of gas porosity is known mainly due to the air entrapment during the injection stage. Most of numerical simulations for the molten metal flow pattern observations have done in the treating of one phase fluid flow but the gas-liquid interface is essentially multi- phase phenomenon. In this paper, the two-phase fluid flow numerical simulation methods have been adapted to predict the gas porosity generations in the molten metal. The accuracy and the usefulness of the new simulation module have been emphasized and verified through some comparison experiments.

UV NIL공정에서 몰드 중공부 형상과 기포결함에 대한 수치해석 (Numerical Analysis of Effects of Mold Cavity Shape on Bubble Defect Formation in UV NIL)

  • 이호성;김보선;김국원
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.596-602
    • /
    • 2018
  • 최근 나노임프린트 리소그래피 공정이 마이크로/나노 스케일의 소자 개발에 있어서 경제적으로 대량 생산할 수 있는 기술로 주목 받고 있다. 자외선경화 방식의 나노임프린트의 경우 상온 및 저압의 장점과 함께 비진공 환경에서 공정을 통하여 설비 비용의 저감과 생산공정의 고속화를 달성할 수 있다. 그러나 이 경우 비진공 환경에서 발생하는 기포결함의 문제를 해결해야만 한다. 본 연구에서는 비진공 환경에서의 자외선경화 방식의 나노임프린트 공정에서 몰드 중공부 단면의 형상과 기포결함 발생 관계를 연구하였다. 일반적으로 많이 사용되는 사각형 단면과 타원형 단면 그리고 삼각형 단면에 대하여 2차원 유동해석 및 VOF 방법을 통하여 기포결함을 시뮬레이션 하였고 단면의 형상과 다양한 접촉각에 따른 유동선단의 특성을 분석하였다. 해석결과 몰드 중공부 형상은 기포결함 발생에 매우 중요한 영향을 미치며, 고려된 형상 모두 몰드와의 접촉각이 작을수록, 기판과의 접촉각이 클수록 기포결함 발생 가능성이 작아짐을 알 수 있었다. 또한 타원형 형상이 기포결함 발생방지 측면에서 가장 효과적임을 확인하였다.

$H_2$ gas flow rate가 비정질 실리콘 박막 태양전지의 i-layer에 미치는 영향에 대한 simulation

  • 박승만;공대영;이원백
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.303-303
    • /
    • 2010
  • 비정질 실리콘 박막 태양전지의 수광부인 i-layer는 비정질의 특성 상 많은 defect을 함유하고 있다. 이러한 defect들은 빛에 의하여 생성된 전자정공 재결합에 있어서 주도적으로 작용하게 된다. $H_2$는 이러한 defect들의 생성을 줄여주어 박막의 특성을 향상시켜주는 것으로 알려져 있다. 본 논문에서는 비정질 박막 태양전지의 수광부로 사용되어지는 i-layer의 $H_2$ gas flow rate의 변화에 따른 태양전지의 특성을 simulation해 보았다. $H_2$는 1:0에 1:5까지 변화시켰고 그에 따른 태양전지의 QE, LIV, DIV 곡선을 통하여 특성을 알아보았다. 또한 추가적으로 i-layer의 두께에 따른 효율의 변화도 simulation해 보았다.

  • PDF

SVM과 인공신경망을 이용한 속도 및 연료유량 변화에 따른 가스터빈 엔진의 결함 진단 연구 (Defect Diagnostics of Gas Turbine Engine with Mach Number and Fuel Flow Variations Using Hybrid SVM-ANN)

  • 최원준;이상명;노태성;최동환
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.289-292
    • /
    • 2006
  • 본 논문에서는 항공기용 터보 축 엔진의 결함진단 알고리즘으로 지지 벡터 장치(Support Vector Machine) 과 인공신경망(Artificial Neural Network) 을 복합으로 이용하였다. 인공신경망 알고리즘의 특성상 데이터 수에 따라 정확성과 수렴속도 등에서 차이가 나므로 탈설계 영역에서의 효용성여부를 판단하기 위해서 연료유량과 마하수에 따른 탈설계 영역 진단 결과를 지상정지 상태와 비교하였다.

  • PDF

Right to Left Atrial Septum Defect Compounded with Patent Ductus Arteriosus in a Maltese Dog

  • Ahn, Sung-Taek;Kim, Myung-Jun;Yoon, Won-Kyoung;Suh, Sang-il;Hyun, Changbaig
    • 한국임상수의학회지
    • /
    • 제34권2호
    • /
    • pp.90-93
    • /
    • 2017
  • A nine-month-old intact female Maltese dog (body weight: 1.5 kg) presented with frequent syncopal episodes (1-2/day), exercise intolerance, and dyspnea. Cardiomegaly with marked dilation of right and left atria along with ascites was indicated on radiography. Tricuspid regurgitant jets (4.36 m/s), pulmonary regurgitant jets (3.4 m/s), left-to-right shunting flow at the ductus arteriosus, and an atrial septal defect were observed on echocardiography. A bubble study with agitated saline found right-to-left shunting at the interatrial septum. Based on diagnostic studies, the dog was diagnosed with right-to-left atrial septum defect (ASD) compounded with patent ductus arteriosus (PDA). The treatment was directed to reduce the pulmonary hypertension, improve cardiac performance, and lower fluid retention. Despite medical treatment for 2 months, the dog died of sudden cardiac arrest. Herein, we describe a very rare case of right-to-left ASD compounded with PDA.

Strength characteristics and fracture evolution of rock with different shapes inclusions based on particle flow code

  • Xia, Zhi G.;Chen, Shao J.;Liu, Xing Z.;Sun, Run
    • Geomechanics and Engineering
    • /
    • 제22권5호
    • /
    • pp.461-473
    • /
    • 2020
  • Natural rock mass contains defects of different shapes, usually filled with inclusions such as clay or gravel. The presence of inclusions affects the failure characteristics and mechanical properties of rock mass. In this study, the strength and failure characteristics of rock with inclusions were studied using the particle flow code under uniaxial compression. The results show that the presence of inclusions not only improves the mechanical properties of rock with defects but also increases the bearing capacity of rock. Circular inclusion has the most obvious effect on improving model strength. The inclusions affect the stress distribution, development of initial crack, change in crack propagation characteristics, and failure mode of rock. In defect models, concentration area of the maximum tensile stress is generated at the top and bottom of defect, and the maximum compressive stress is distributed on the left and right sides of defect. In filled models, the tensile stress and compressive stress are uniformly distributed. Failing mode of defect models is mainly tensile failure, while that of filled models is mainly shear failure.

위상잠금 광-적외선 열화상 기술을 이용한 감육결함이 있는 직관시험편의 결함 검출 (Defect detection of wall thinning defect in pipes using Lock-in photo-infrared thermography technique)

  • 김경석;장수옥;박종현;;송재근;정현철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.317-321
    • /
    • 2008
  • Piping in the Nuclear Power plants (NPP) are mostly consisted of carbon steel pipe. The wall thinning defect is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid which flows in carbon steel pipes. This type of defect becomes the cause of damage or destruction of piping. Therefore, it is very important to measure defect which is existed not only on the welding partbut also on the whole field of pipe. Over the years, Infrared thermography (IRT) has been used as a non destructive testing methods of the various kinds of materials. This technique has many merits and applied to the industrial field but has limitation to the materials. Therefore, this method was combined with lock-in technique. So IRT detection resolution has been progressively improved using lock-in technique. In this paper, the quantitative analysis results of the location and the size of wall thinning defect that is artificially processed inside the carbon steel pipe by using IRT are obtained.

  • PDF

외상성 심실중격결손증 1례 보 (Traumatic ventricular septal defect - One case report -)

  • 성후식
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.411-415
    • /
    • 1987
  • We have experienced a rare case of traumatic ventricular septal defect caused by fall down injury. The patient suffered from congestive heart failure after trauma and represented new developing typical murmur. Cardiac catheterization revealed a large left-to-right shunt at the ventricular level and a 4.4:1 ratio of pulmonary to systemic flow. Left ventricular angiogram also showed ventricular septal defect low in the muscular septum. At operation, the right ventricle and pulmonary artery were found to be moderately dilated. A marked systolic thrill was palpable over the right ventricle near the apex. Through a small left ventriculotomy an oval defect, 2x.3 cm with a firm scarred margin, was found in the lower muscular ventricular septum. This defect was repaired using Dacron patch and ventriculotomy was closed with long strip of Teflon felt. Postoperative course was uneventful and discharged in good condition.

  • PDF