• Title/Summary/Keyword: Flow controller

Search Result 710, Processing Time 0.032 seconds

Continuous Ice Slurry Production and Control of Ice Packing Factor in a Pipe for the District Cooling (지역냉방을 위한 아이스슬러리의 연속제조 및 배관내 빙충전율 조절)

  • Kwon, Jae-Sung;Lee, Yoon-Pyo;Lee, Sang-Hoon;Yoo, Ho-Seon;Yoon, Seok-Mann
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.825-832
    • /
    • 2008
  • The ice slurry maker which can produce the ice slurry well for the ice particle in-flowing condition was revised. We removed the stagnant region at the top of the ice slurry maker, and IPF 40% could be realized. The IPF controller with 6 mm diameter holes at the bottom was designed. But the IPF controller with only 6 mm diameter holes could not control IPF in a pipe. This is because the ice particles at ice slurry flow exist homogeneously not only at the upper part but also at the bottom part. We changed the hole size of IPF controller surface using fine meshes and then, IPF in a pipe was increased by 70% when the hole size was $80{\mu}m$ and less.

Development of an AGV Controller in Semiconductor and LCD Production Systems (반도체 및 LCD 제조 공정의 AGV Controller 개발)

  • Suh, Jungdae;Jang, Jaejin;Koo, Pyung-Hoi
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.29 no.1
    • /
    • pp.1-13
    • /
    • 2003
  • In this paper, LAC(Look-ahead AGV Controller) has been developed for efficient routing of parts in semiconductor and LCD production systems. Several procedures have been developed as sub-modules. LACP(Look-ahead AGV Control Procedure) which controls AGVs using the information on the current and future status of the systems is the main element of the LAC. To support LACP, DSP(Destination Selection Procedure) which determines a destination of a part and AGV call time, SSP(Source Selection Procedure)which selects a part coming next to a buffer when the buffer becomes available. and RTM(Response Time Model) which estimates empty travel time of AGVs and waiting time for an available AGV have been developed. A simulation experiment shows that LAC reduces part's flow time, AGV utilization, average and maximum inventory level of a central buffer, empty travel time of an AGV, and waiting time for an available AGV.

The level control of Steam Generator in Nuclear Power Plant by Neural Network-PI Controller (PI-신경망 제어기를 이용한 원자력 발전소용 증기 발생기 수위제어)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.6-13
    • /
    • 1998
  • It is difficult to control for the level of the steam generator in the nuclear power plant because there is swell and shrink, and many disturbance such as, feed water rate, feedwater temperature, main steam flow rte, coolant temperature effect steam generator level. If the conventional PI controller use in this system, we cannot have a stability in the control of the lower power, the rejection function of disturbance, and the load following effectively. In this paper, e study the application of the of neural network based Kp, Ti for Pi controller to the level control of the steam generator of nuclear power plant through the simulation and experimental on the steam generator. We are satisfied with the resulting against the inturrupt of the disturbance, the change of setpoint through the simulation and the swell and shrink, the response of controller on the experimental steam generator.

  • PDF

Development of the controller for peeling off the enamel and forming of deflection yoke coil (편향요크코일의 에나멜 탈피 및 통전성형을 위한 탈피통전기의 개발)

  • Jeong, Soo-Hoa;Yun, Jong-Soon;Kwon, Woo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.202-205
    • /
    • 1995
  • Developed controller is the part of deflection yoke winding machine which controls the power to form the deflection yoke coil into desired shape after winding. So as to form the deflection yoke coil, it is needed to melt the bonding material which is spreaded on the coil. The heat melt the bonding material which is produced by flowing the current through the winded coil. Therefore, at first it is needed to peel off the enamel from the winded coil so as to flow the current, and then supply the power to produce the heat which form the winded coil into desired shape. Naturally developed controller is composed of the peeling part and the conduction and forming part. All of them consist of the inverter structure and control the output current. The peeling is achieved by low voltage and high AC current, the conduction and forming is by DC current. Developed controller also has a function that detect the resistance of the deflection yoke coil to prevent the damage of the load which is produced by poor peeling.

  • PDF

A Study on the Load Frequency control of Power System Using Neural Network Self Tuning PID Controller (신경회로망 자기종조 PID 제어기를 이용한 전력계통의 부하주파수제어에 관한 연구)

  • 정형환;김상효;주석민;김경훈
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.8 no.5
    • /
    • pp.29-38
    • /
    • 1998
  • This paper proposes the neural network self-tuning PID controller for the load frequency control of 2- areas power system, namely, the prompt convergence of frequency and tie-line power flow deviation. The neural network applied to computer simulation consists of neurons of two inputs, ten hiddens and tliree outputs layer. Neurons of two inputs layer receive the error and its change rate of the system and cutputs layer consists of three neurons for the parameters of the PID controller. The simulation results shows that the proposed neural network self-tuning PID controller is superior to conventional control t~:chniques(Optimal, PID) in dynamic response and control performance.

  • PDF

Methodological Approaches to Reduce Uncertainties Associated with Air Sampling : Development and Assessment of a Six-port Manifold MFC System (대기 중 오염물질의 시료채취시 관측오차 저감방법에 대한 연구 : 6구형 매니폴더를 장착한 MFC system의 개발과 평가)

  • 김기현;오상인;최여진;김민영;최규훈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.377-386
    • /
    • 2003
  • In order to develop a confident sampling technique, we designed and constructed a 6-port manifold MFC sampling system for collecting gaseous pollutants in air. Using this instrumentation, we tested the performance criteria of MFC system in terms of: (1) flow rate; (2) MFC-to-MFC variability; (3) tube-to-tube variability; and (4) time. It was interesting to find that the later two factors did not show any significant variations, while the former two show substantially large variations. However, as most of those variabilities are consistent enough to form systematic patterns, we were able to explain the occurrence patterns of all those MFC biases in terms of those four major variables. The overall results of our experiment suggest that one needs to use correction factor for each MFC unit under a given flow rate to maintain optimal accuracy and precision for sampling of those pollutants.

Formation characteristics of gas hydrate in sediments (퇴적층에서의 가스 하이드레이트 생성 특성)

  • Lee, Jae-Hyoung;Lee, Won-Suk;Kim, Se-Joon;Kim, Hyun-Tae;Huh, Dae-Gi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.630-633
    • /
    • 2005
  • Some gases can be formed into hydrate by physical combination with water under appropriate temperature and pressure condition. Besides them, it was found that the pore size of the sediments can affect the formation and dissociation of hydrate. In this study, formation temperatures of carbon dioxide and methane hydrate have been measured using isobaric method to investigate the effects of flow rates of gases on formation condition of hydrate in porous rock samples. The flow rates of gases were controlled using a mass flow controller. To minimize Memory effect, system temperature increased for the dissociation of gas hydrates and re-established the initial saturation. The results show that the formation temperature of hydrate decreases with increasing the injection flow rate of gas. This indicates that the velocity of gas in porous media may act as kinds of inhibitor for the formation of hydrate.

  • PDF

Flow/Pressure/Power Control of Hydraulic Pump Utilizing Switching Control Mode (스위칭 제어 모드를 이용한 유압펌프의 유량/압력/동력 제어)

  • Jung, D.S.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.8-14
    • /
    • 2007
  • The electro-hydraulic pump is usually used in testing equipments which require one control function. But until now, it is not applied to industrial equipments which are exposed to severe working environment and require various control functions. This paper proposes a technique which controls continuously flow, pressure and power by utilizing switching control mode. Mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

  • PDF

The Effects of FACTS Application Considering UPFG Capacity (UPFC용량을 고려한 FACTS 적용 효과 연구)

  • Yoon, Jong-Su;Won, Jong-Ryul;Jang, Byung-Hoon;Jeon, Young-Soo;Oh, Kwan-Il;Lee, Ki-Sun;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1296-1298
    • /
    • 1999
  • This paper describes a power flow method for the unified power flow controller(UPFC) considering equipment sizes and constraints. The operation of UPFC subject to the practical constraints encounted in an actual high power installation. So the Power flow method for FACTS must be considered its constraints for power system analysis. The proposed UPFC power flow method was implemented by PSS/E and IPLAN.

  • PDF

Flow Compensating Characteristics for the Speed Variation of a Boom Sprayer (붐방제기용 주행속도 보상식 유량제어부의 동특성)

  • 구영모;정재은
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.115-124
    • /
    • 1998
  • Over- and under-application of pesticides to crops have recently become main concerns regarding the environment conservation, product cost and firmer's safety. Thus, a uniform and optimal application method of pesticides was needed. The objective of study was to evaluate flow compensating characteristics of a variable flow control system for a boom sprayer using a laboratory setup. At the most variable conditions, the control system was acceptable with the flowrate control strategy. However, the sprayer control system became unstably fluctuating at the long execution time with small tolerance because of the constant valve on-time. This problem was solved by employing a variable on-time control. The optimal values for the damping ratio and the execution time were 2 and 1.0 sec, respectively, with the tolerances less than 3%. The performance of the control system at the optimal conditions were the response time of 3.8sec and the absolute steady-state error of 0.5% with the stable RCV and ROS ( < 1.0).

  • PDF