• Title/Summary/Keyword: Flow control system

Search Result 3,071, Processing Time 0.034 seconds

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Immuno-stimulatory Activities of a High Molecular Weight Fraction from Cynanchum wilfordii Radix Obtained by Ultrafiltration (한외거르기(Ultrafiltration)에 의하여 분리된 백수오 고분자 분획물의 면역증진 활성)

  • Jang, Mi;Lim, Tae-Gyu;Hong, Hee-Do;Rhee, Young Kyoung;Kim, Kyung-Tack;Lee, Eunjung;Lee, Jeong Hoon;Lee, Yun Ji;Kim, Yeon Bok;Cho, Chang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.268-274
    • /
    • 2016
  • The purpose of this study was to investigate the immuno-stimulatory activity of the high-molecular-weight fraction (HMWF) of Cynanchum wilfordii (CW) extracts obtained by ultrafiltration in murine macrophage RAW 264.7 cells and to assess its immuno-stimulatory effect in mice. Ultrafiltration was performed with polyethersulfone membranes (30 kDa cutoff) in a cross-flow filtration system to obtain the HMWF of CW. The results showed that the HMWF increased the production of various cytokines such as tumor necrosis factor-${\alpha}$, interleukin-6, and nitric oxide in dose-ependent manners. In addition, HMWF treatment increased the relative spleen weight as well as splenocyte proliferation induced by concanavalin A or bacterial lipopolysaccharide in mice. Natural killer (NK) cell activity in the HMWF-treated group was significantly increased compared to that in the control group. These results suggest that the HMWF of CW can support the immune system through secretion of macrophage cytokines, thereby enhancing NK cell activity and murine splenocyte proliferation.

A Study on the Acceptance of Convergence System of Broadcasting, and Telecommunication, and Their Relative Efficiency Focusing on IPFV (방송과 통신 융합시스템의 수용 및 상대적 효능에 관한 연구: IPTV를 중심으로)

  • Um, Myoung-Yong;Lee, Sang-Ho;Kim, Jai-Beam
    • Asia pacific journal of information systems
    • /
    • v.19 no.3
    • /
    • pp.25-49
    • /
    • 2009
  • Advances in technology have resulted in the emergence of new information systems. The convergence of IT and manufacturing sectors has blurred the boundaries among industries. Also, such convergence has become established as a paradigm to build a new area. Especially the convergence of broadcasting and telecommunication, notably in the case of IPTV (Internet Protocol Television), is among the most salient examples of its kind in recent years as a major case of disruptive technology innovation. Despite its much fanfare, such convergence, however, has not fulfilled the expectation; it has not produced positive economic effects while negatively affecting the growth of IPIV. Stakeholders in and around IPIV including telecommunication companies, broadcasting corporations, and government bodies wish to gain control of IPTV under their wings. IPTV has drifted in the midst of conflicts among the stakeholders in and around IPTV, particularly telecommunication and broadcasting organizations in a broad sense. Our empirical research intends to deal with how audiences accept IPTV and how firms provide IPTV services to utilize their resources. Three research questions in this paper include, first, whether Technology Acceptance Model (TAM) can sufficiently explain the acceptance of IPTV as an information system. The second question concerns with empirically testing the playful aspect of IPTV to increase its audience acceptance. Last, but not least, this paper deals with how firms can efficiently and effectively allocate their limited resources to increase IPTV viewers. To answer those three main questions of our study, we collect data from 197 current subscribers of high speed internet service and/or cable/satellite television. Empirical results show that 'perceived usefulness (PU) $\rightarrow$ Intention to use' and 'perceived ease of use (PEU) $\rightarrow$ Intention to use' are significant. Also, 'perceived ease of use' is significantly related to 'perceived usefulness.' Perceived ease of handling IPTV without much effort can positively influence the perceived value of IPTV. In this regard, engineers and designers of IPTV should pay more attention to the user-friendly interface of IPTV. In addition, 'perceived playfulness (PP)' of IPTV is positively related to 'intention to use'. Flow, fun and entertainment have recently gained greater attention in the research concerned with information systems. Such attention is due to the changing features of information systems in recent years that combine the functional and leisure attributes. These results give practical implications to the design of IPTV that reflects not just leisure but also functional elements. This paper also investigates the relationship between 'perceived ease of use (PEU)' and 'perceived playfulness (PP).' PEU is positively related to pp. Audiences without fear can be attracted more easily to the user-friendly IPTV, thereby perceiving the fun and entertainment with ease. Practical implications from this finding are that, to attract more interest and involvement from the audience, IPTV needs to be designed with similar or even more user friendly interface. Of the factors related to 'intention to use', 'perceived usefulness (PU)' and 'perceived ease of use (PEU)' have greater impacts than 'perceived playfulness (PP).' Between PU and PEU, their impacts on 'intention to use' are not significantly different statistically. Managerial implications of this finding are that firms in preparation for the launch of IPTV service should prioritize the functions and interface of IPTV. This empirical paper also provides further insight into the ways in which firms can strategically allocate their limited resources so as to appeal to viewers, both current and potential, of IPTV.

Problems with ERP Education at College and How to Solve the Problems (대학에서의 ERP교육의 문제점 및 개선방안)

  • Kim, Mang-Hee;Ra, Ki-La;Park, Sang-Bong
    • Management & Information Systems Review
    • /
    • v.31 no.2
    • /
    • pp.41-59
    • /
    • 2012
  • ERP is a new technique of process innovation. It indicates enterprise resource planning whose purpose is an integrated total management of enterprise resources. ERP can be also seen as one of the latest management systems that organically connects by using computers all business processes including marketing, production and delivery and control those processes on a real-time basis. Currently, however, it's not easy for local enterprises to have operators who will be in charge of ERP programs, even if they want to introduce the resource management system. This suggests that it's urgently needed to train such operators through ERP education at school. But in the field of education, actually, the lack of professional ERP instructors and less effective learning programs for industrial applications of ERP are obstacles to bringing up ERP workers who are competent as much as required by enterprises. In ERP, accounting is more important than any others. Accountants are assuming more and more roles in ERP. Thus, there's a rapidly increasing demand for experts in ERP accounting. This study examined previous researches and literature concerning ERP education, identified problems with current ERP education at college and proposed how to solve the problems. This study proposed the ways of improving ERP education at college as follows. First, a prerequisite learning of ERP, that is, educating the principle of accounting should be intensified to make students get a basic theoretical knowledge of ERP enough. Second, lots of different scenarios designed to try ERP programs in business should be created. In association, students should be educated to get a better understanding of incidents or events taken place in those scenarios and apply it to trying ERP for themselves. Third, as mentioned earlier, ERP is a system that integrates all enterprise resources such as marketing, procurement, personnel management, remuneration and production under the framework of accounting. It should be noted that under ERP, business activities are organically connected with accounting modules. More importantly, those modules should be recognized not individually, but as parts comprising a whole flow of accounting. This study has a limitation because it is a literature research that heavily relied on previous studies, publications and reports. This suggests the need to compare the efficiency of ERP education between before and after applying what this study proposed to improve that education. Also, it's needed to determine students' and professors' perceived effectiveness of current ERP education and compare and analyze the difference in that perception between the two groups.

  • PDF

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF

A Feasibility Study on the Deep Soil Mixing Barrier to Control Contaminated Groundwater (오염지하수의 확산방지를 위한 대체 혼합차수재의 적용에 관한 연구)

  • 김윤희;임동희;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.53-59
    • /
    • 2001
  • There is a lot of method to manage the insanitary landfill but vertical cutoff walls have been widespreadly used and were installed into the subsurface to act as a barrier to horizontal groundwater flow, The stabilized material such as specialized cement or mixed soil with additives has been generally applied for the materials of the deep soil mixing barrier in korea. The amount of the stabilized material is dependent on the field conditions, because the mixing ratio of the material and the field soil should achieve a requirement in the coefficient of permeability, lower than 1.0$\times$$10^{7}$cm/sec. This study determined the quantity and optimized function ratio of the stabilized material in the formation process of the mixed barrier that was added with stabilized material on the field soil classified into SW-SC under USCS (Unified Soil Classification System). After that the fly ash and lime were selected as an additives an that could improve the function of the stabilized material and then the method to improve the functional progress in the usage of putting into the stabilized material as an appropriate ratio was studied and reviewed. The author used the flexible-wall permeameter for measuring the permeability and unconfined compressive strength tester for compressive strength, and in the view of environmental engineering the absorption test of heavy metals and leaching test regulated by Korean Waste Management Act were performed. As the results, the suitable mixing ratio of the stabilized material in the deep soil mixing barrier was determined as 13 percent. To make workability easy, the ratio of stabilized material and water was proven to be 1 : 1.5. With the results, the range of the portion of the additives(fly ash : lime= 70 : 30) was proven to be 20-40% for improving the function of the stabilized material, lowering of permeability. In heavy metal absorption assessment of the mixing barrier system with the additives, the result of heavy metal absorption was proved to be almost same with the case of the original stabilized material; high removal efficiency of heavy metals. In addition, the leaching concentration of heavy metals from the leaching test for the environmental hazard assessment showed lower than the regulated criteria.

  • PDF

Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam (전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성)

  • Lee, Jin-Yong;Choi, Mi-Jung;Kim, Hyun-Jung;Cho, Byung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.33-44
    • /
    • 2009
  • Water curtain of an underground LPG storage cavern is a facility to prevent leakage of high pressure gases, for which groundwater should flow freely towards the cavern and groundwater level also must be stably maintained. In this study, in order to evaluate qualities of seepage water and surrounding groundwater of an underground LPG storage cavern in Yeosu, 4 rounds of samplings, field measurements and laboratory analyses (February, May, August, October of 2007) were conducted. According to field measurements, pH was weak acidic to neutral but it gradually increased with time. Electrical conductivity (EC) of groundwater near a salt stack showed very high values between 10.47 and 38.50 mS/cm. Dissolved oxygen (DO) showed a very wide range of 0.20~8.74 mg/L and a mean of oxidation-reduction potential (ORP) was 159 mV, which indicated an oxidized condition. Levels of $Fe^{2+}$ and $Mn^{2+}$ were mostly less than 3 mg/L. All of seepage waters showed a Na-Cl type while only groundwater near the salt stack showed a Na-Cl type with a high total dissolved solid. The other groundwaters exhibited typical $Ca-HCO_3$ types. Levels of aerobic bacteria were mostly very high (573-39,520 CFU/mL). Based on the analyses of these hydrochemistry and biological characteristics, it is concluded that there are no particular problems in groundwater and seepage water, which not causing a trouble in the cavern operation. However, both for control of bio-clogging and for sustainable operation of the water curtain system, a regular hydrochemical and microbiological monitoring is required for the seepage water and surrounding groundwater.

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.

Field Studios of In-situ Aerobic Cometabolism of Chlorinated Aliphatic Hydrocarbons

  • Semprini, Lewts
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.3-4
    • /
    • 2004
  • Results will be presented from two field studies that evaluated the in-situ treatment of chlorinated aliphatic hydrocarbons (CAHs) using aerobic cometabolism. In the first study, a cometabolic air sparging (CAS) demonstration was conducted at McClellan Air Force Base (AFB), California, to treat chlorinated aliphatic hydrocarbons (CAHs) in groundwater using propane as the cometabolic substrate. A propane-biostimulated zone was sparged with a propane/air mixture and a control zone was sparged with air alone. Propane-utilizers were effectively stimulated in the saturated zone with repeated intermediate sparging of propane and air. Propane delivery, however, was not uniform, with propane mainly observed in down-gradient observation wells. Trichloroethene (TCE), cis-1, 2-dichloroethene (c-DCE), and dissolved oxygen (DO) concentration levels decreased in proportion with propane usage, with c-DCE decreasing more rapidly than TCE. The more rapid removal of c-DCE indicated biotransformation and not just physical removal by stripping. Propane utilization rates and rates of CAH removal slowed after three to four months of repeated propane additions, which coincided with tile depletion of nitrogen (as nitrate). Ammonia was then added to the propane/air mixture as a nitrogen source. After a six-month period between propane additions, rapid propane-utilization was observed. Nitrate was present due to groundwater flow into the treatment zone and/or by the oxidation of tile previously injected ammonia. In the propane-stimulated zone, c-DCE concentrations decreased below tile detection limit (1 $\mu$g/L), and TCE concentrations ranged from less than 5 $\mu$g/L to 30 $\mu$g/L, representing removals of 90 to 97%. In the air sparged control zone, TCE was removed at only two monitoring locations nearest the sparge-well, to concentrations of 15 $\mu$g/L and 60 $\mu$g/L. The responses indicate that stripping as well as biological treatment were responsible for the removal of contaminants in the biostimulated zone, with biostimulation enhancing removals to lower contaminant levels. As part of that study bacterial population shifts that occurred in the groundwater during CAS and air sparging control were evaluated by length heterogeneity polymerase chain reaction (LH-PCR) fragment analysis. The results showed that an organism(5) that had a fragment size of 385 base pairs (385 bp) was positively correlated with propane removal rates. The 385 bp fragment consisted of up to 83% of the total fragments in the analysis when propane removal rates peaked. A 16S rRNA clone library made from the bacteria sampled in propane sparged groundwater included clones of a TM7 division bacterium that had a 385bp LH-PCR fragment; no other bacterial species with this fragment size were detected. Both propane removal rates and the 385bp LH-PCR fragment decreased as nitrate levels in the groundwater decreased. In the second study the potential for bioaugmentation of a butane culture was evaluated in a series of field tests conducted at the Moffett Field Air Station in California. A butane-utilizing mixed culture that was effective in transforming 1, 1-dichloroethene (1, 1-DCE), 1, 1, 1-trichloroethane (1, 1, 1-TCA), and 1, 1-dichloroethane (1, 1-DCA) was added to the saturated zone at the test site. This mixture of contaminants was evaluated since they are often present as together as the result of 1, 1, 1-TCA contamination and the abiotic and biotic transformation of 1, 1, 1-TCA to 1, 1-DCE and 1, 1-DCA. Model simulations were performed prior to the initiation of the field study. The simulations were performed with a transport code that included processes for in-situ cometabolism, including microbial growth and decay, substrate and oxygen utilization, and the cometabolism of dual contaminants (1, 1-DCE and 1, 1, 1-TCA). Based on the results of detailed kinetic studies with the culture, cometabolic transformation kinetics were incorporated that butane mixed-inhibition on 1, 1-DCE and 1, 1, 1-TCA transformation, and competitive inhibition of 1, 1-DCE and 1, 1, 1-TCA on butane utilization. A transformation capacity term was also included in the model formation that results in cell loss due to contaminant transformation. Parameters for the model simulations were determined independently in kinetic studies with the butane-utilizing culture and through batch microcosm tests with groundwater and aquifer solids from the field test zone with the butane-utilizing culture added. In microcosm tests, the model simulated well the repetitive utilization of butane and cometabolism of 1.1, 1-TCA and 1, 1-DCE, as well as the transformation of 1, 1-DCE as it was repeatedly transformed at increased aqueous concentrations. Model simulations were then performed under the transport conditions of the field test to explore the effects of the bioaugmentation dose and the response of the system to tile biostimulation with alternating pulses of dissolved butane and oxygen in the presence of 1, 1-DCE (50 $\mu$g/L) and 1, 1, 1-TCA (250 $\mu$g/L). A uniform aquifer bioaugmentation dose of 0.5 mg/L of cells resulted in complete utilization of the butane 2-meters downgradient of the injection well within 200-hrs of bioaugmentation and butane addition. 1, 1-DCE was much more rapidly transformed than 1, 1, 1-TCA, and efficient 1, 1, 1-TCA removal occurred only after 1, 1-DCE and butane were decreased in concentration. The simulations demonstrated the strong inhibition of both 1, 1-DCE and butane on 1, 1, 1-TCA transformation, and the more rapid 1, 1-DCE transformation kinetics. Results of tile field demonstration indicated that bioaugmentation was successfully implemented; however it was difficult to maintain effective treatment for long periods of time (50 days or more). The demonstration showed that the bioaugmented experimental leg effectively transformed 1, 1-DCE and 1, 1-DCA, and was somewhat effective in transforming 1, 1, 1-TCA. The indigenous experimental leg treated in the same way as the bioaugmented leg was much less effective in treating the contaminant mixture. The best operating performance was achieved in the bioaugmented leg with about over 90%, 80%, 60 % removal for 1, 1-DCE, 1, 1-DCA, and 1, 1, 1-TCA, respectively. Molecular methods were used to track and enumerate the bioaugmented culture in the test zone. Real Time PCR analysis was used to on enumerate the bioaugmented culture. The results show higher numbers of the bioaugmented microorganisms were present in the treatment zone groundwater when the contaminants were being effective transformed. A decrease in these numbers was associated with a reduction in treatment performance. The results of the field tests indicated that although bioaugmentation can be successfully implemented, competition for the growth substrate (butane) by the indigenous microorganisms likely lead to the decrease in long-term performance.

  • PDF

The lesson From Korean War (한국전쟁의 교훈과 대비 -병력수(兵力數) 및 부대수(部隊數)를 중심으로-)

  • Yoon, Il-Young
    • Journal of National Security and Military Science
    • /
    • s.8
    • /
    • pp.49-168
    • /
    • 2010
  • Just before the Korean War, the total number of the North Korean troops was 198,380, while that of the ROK(Republic of Korea) army troops 105,752. That is, the total number of the ROK army troops at that time was 53.3% of the total number of the North Korean army. As of December 2008, the total number of the North Korean troops is estimated to be 1,190,000, while that of the ROK troops is 655,000, so the ROK army maintains 55.04% of the total number of the North Korean troops. If the ROK army continues to reduce its troops according to [Military Reform Plan 2020], the total number of its troops will be 517,000 m 2020. If North Korea maintains the current status(l,190,000 troops), the number of the ROK troops will be 43.4% of the North Korean army. In terms of units, just before the Korean War, the number of the ROK army divisions and regiments was 80% and 44.8% of North Korean army. As of December 2008, North Korea maintains 86 divisions and 69 regiments. Compared to the North Korean army, the ROK army maintains 46 Divisions (53.4% of North Korean army) and 15 regiments (21.3% of North Korean army). If the ROK army continue to reduce the military units according to [Military Reform Plan 2020], the number of ROK army divisions will be 28(13 Active Division, 4 Mobilization Divisions and 11 Local Reserve Divisions), while that of the North Korean army will be 86 in 2020. In that case, the number of divisions of the ROK army will be 32.5% of North Korean army. During the Korean war, North Korea suddenly invaded the Republic of Korea and occupied its capital 3 days after the war began. At that time, the ROK army maintained 80% of army divisions, compared to the North Korean army. The lesson to be learned from this is that, if the ROK army is forced to disperse its divisions because of the simultaneous invasion of North Korea and attack of guerrillas in home front areas, the Republic of Korea can be in a serious military danger, even though it maintains 80% of military divisions of North Korea. If the ROK army promotes the plans in [Military Reform Plan 2020], the number of military units of the ROK army will be 32.5% of that of the North Korean army. This ratio is 2.4 times lower than that of the time when the Korean war began, and in this case, 90% of total military power should be placed in the DMZ area. If 90% of military power is placed in the DMZ area, few troops will be left for the defense of home front. In addition, if the ROK army continues to reduce the troops, it can allow North Korea to have asymmetrical superiority in military force and it will eventually exert negative influence on the stability and peace of the Korean peninsular. On the other hand, it should be reminded that, during the Korean War, the Republic of Korea was attacked by North Korea, though it kept 53.3% of troops, compared to North Korea. It should also be reminded that, as of 2008, the ROK army is defending its territory with the troops 55.04% of North Korea. Moreover, the national defense is assisted by 25,120 troops of the US Forces in Korea. In case the total number of the ROK troops falls below 43.4% of the North Korean army, it may cause social unrest about the national security and may lead North Korea's misjudgement. Besides, according to Lanchester strategy, the party with weaker military power (60% compared to the party with stronger military power) has the 4.1% of winning possibility. Therefore, if we consider the fact that the total number of the ROK army troops is 55.04% of that of the North Korean army, the winning possibility of the ROK army is not higher than 4.1%. If the total number of ROK troops is reduced to 43.4% of that of North Korea, the winning possibility will be lower and the military operations will be in critically difficult situation. [Military Reform Plan 2020] rums at the reduction of troops and units of the ground forces under the policy of 'select few'. However, the problem is that the financial support to achieve this goal is not secured. Therefore, the promotion of [Military Reform Plan 2020] may cause the weakening of military defence power in 2020. Some advanced countries such as Japan, UK, Germany, and France have promoted the policy of 'select few'. However, what is to be noted is that the national security situation of those countries is much different from that of Korea. With the collapse of the Soviet Unions and European communist countries, the military threat of those European advanced countries has almost disappeared. In addition, the threats those advanced countries are facing are not wars in national level, but terrorism in international level. To cope with the threats like terrorism, large scaled army trops would not be necessary. So those advanced European countries can promote the policy of 'select few'. In line with this, those European countries put their focuses on the development of military sections that deal with non-military operations and protection from unspecified enemies. That is, those countries are promoting the policy of 'select few', because they found that the policy is suitable for their national security environment. Moreover, since they are pursuing common interest under the European Union(EU) and they can form an allied force under NATO, it is natural that they are pursing the 'select few' policy. At present, NATO maintains the larger number of troops(2,446,000) than Russia(l,027,000) to prepare for the potential threat of Russia. The situation of japan is also much different from that of Korea. As a country composed of islands, its prime military focus is put on the maritime defense. Accordingly, the development of ground force is given secondary focus. The japanese government promotes the policy to develop technology-concentrated small size navy and air-forces, instead of maintaining large-scaled ground force. In addition, because of the 'Peace Constitution' that was enacted just after the end of World War II, japan cannot maintain troops more than 240,000. With the limited number of troops (240,000), japan has no choice but to promote the policy of 'select few'. However, the situation of Korea is much different from the situations of those countries. The Republic of Korea is facing the threat of the North Korean Army that aims at keeping a large-scale military force. In addition, the countries surrounding Korea are also super powers containing strong military forces. Therefore, to cope with the actual threat of present and unspecified threat of future, the importance of maintaining a carefully calculated large-scale military force cannot be denied. Furthermore, when considering the fact that Korea is in a peninsular, the Republic of Korea must take it into consideration the tradition of continental countries' to maintain large-scale military powers. Since the Korean War, the ROK army has developed the technology-force combined military system, maintaining proper number of troops and units and pursuing 'select few' policy at the same time. This has been promoted with the consideration of military situation in the Koran peninsular and the cooperation of ROK-US combined forces. This kind of unique military system that cannot be found in other countries can be said to be an insightful one for the preparation for the actual threat of North Korea and the conflicts between continental countries and maritime countries. In addition, this kind of technology-force combined military system has enabled us to keep peace in Korea. Therefore, it would be desirable to maintain this technology-force combined military system until the reunification of the Korean peninsular. Furthermore, it is to be pointed out that blindly following the 'select few' policy of advanced countries is not a good option, because it is ignoring the military strategic situation of the Korean peninsular. If the Republic of Korea pursues the reduction of troops and units radically without consideration of the threat of North Korea and surrounding countries, it could be a significant strategic mistake. In addition, the ROK army should keep an eye on the fact the European advanced countries and Japan that are not facing direct military threats are spending more defense expenditures than Korea. If the ROK army reduces military power without proper alternatives, it would exert a negative effect on the stable economic development of Korea and peaceful reunification of the Korean peninsular. Therefore, the desirable option would be to focus on the development of quality of forces, maintaining proper size and number of troops and units under the technology-force combined military system. The tableau above shows that the advanced countries like the UK, Germany, Italy, and Austria spend more defense expenditure per person than the Republic of Korea, although they do not face actual military threats, and that they keep achieving better economic progress than the countries that spend less defense expenditure. Therefore, it would be necessary to adopt the merits of the defense systems of those advanced countries. As we have examined, it would be desirable to maintain the current size and number of troops and units, to promote 'select few' policy with increased defense expenditure, and to strengthen the technology-force combined military system. On the basis of firm national security, the Republic of Korea can develop efficient policies for reunification and prosperity, and jump into the status of advanced countries. Therefore, the plans to reduce troops and units in [Military Reform Plan 2020] should be reexamined. If it is difficult for the ROK army to maintain its size of 655,000 troops because of low birth rate, the plans to establish the prompt mobilization force or to adopt drafting system should be considered for the maintenance of proper number of troops and units. From now on, the Republic of Korean government should develop plans to keep peace as well as to prepare unexpected changes in the Korean peninsular. For the achievement of these missions, some options can be considered. The first one is to maintain the same size of military troops and units as North Korea. The second one is to maintain the same level of military power as North Korea in terms of military force index. The third one is to maintain the same level of military power as North Korea, with the combination of the prompt mobilization force and the troops in active service under the system of technology-force combined military system. At present, it would be not possible for the ROK army to maintain such a large-size military force as North Korea (1,190,000 troops and 86 units). So it would be rational to maintain almost the same level of military force as North Korea with the combination of the troops on the active list and the prompt mobilization forces. In other words, with the combination of the troops in active service (60%) and the prompt mobilization force (40%), the ROK army should develop the strategies to harmonize technology and forces. The Korean government should also be prepared for the strategic flexibility of USFK, the possibility of American policy change about the location of foreign army, radical unexpected changes in North Korea, the emergence of potential threat, surrounding countries' demand for Korean force for the maintenance of regional stability, and demand for international cooperation against terrorism. For this, it is necessary to develop new approaches toward the proper number and size of troops and units. For instance, to prepare for radical unexpected political or military changes in North Korea, the Republic of Korea should have plans to protect a large number of refugees, to control arms and people, to maintain social security, and to keep orders in North Korea. From the experiences of other countries, it is estimated that 115,000 to 230,000 troops, plus ten thousands of police are required to stabilize the North Korean society, in the case radical unexpected military or political change happens in North Korea. In addition, if the Republic of Korea should perform the release of hostages, control of mass destruction weapons, and suppress the internal wars in North Korea, it should send 460,000 troops to North Korea. Moreover, if the Republic of Korea wants to stop the attack of North Korea and flow of refugees in DMZ area, at least 600,000 troops would be required. In sum, even if the ROK army maintains 600,000 troops, it may need additional 460,000 troops to prepare for unexpected radical changes in North Korea. For this, it is necessary to establish the prompt mobilization force whose size and number are almost the same as the troops in active service. In case the ROK army keeps 650,000 troops, the proper number of the prompt mobilization force would be 460,000 to 500,000.

  • PDF