• Title/Summary/Keyword: Flow control plate

Search Result 222, Processing Time 0.023 seconds

Assessment of Microbiological Quality of Outsourced School Meals (외부 운반 학교급식의 미생물학적 품질 평가)

  • Jeong, Hyun-Suk;Ryu, Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.4
    • /
    • pp.372-384
    • /
    • 2012
  • The purpose of this study was to provide a basic resource for establishment of hygienic management standards for meal delivery from the central kitchen to schools. Flow diagrams for delivery of food were analyzed, and time-temperature conditions of the food and environment were measured. Four different foods samples including Mexican salad, radish salad, stir-fried pork and vegetables, and stir-fried chicken and vegetables were collected after production and before service. Microbiological analysis was performed for aerobic plate counts (APC), Enterobacteriaceae, coliforms, E. coli, Salmonella spp., S. aureus, B. cereus, C. perfringens, and L. monocytogenes. After completion of production of cooked foods 2~3 hours were taken for the cooked foods to reach the temperature danger zone. Food temperatures at the meal service did not meet the recommended temperatures ($10/57^{\circ}C$) for conventional school food service systems. The highest APC counts were observed in radish salad (5.70 log CFU/g), followed by Mexican salad (5.18 log CFU/g). Enterobacteriaceae and coliform counts were within acceptable levels of those recommended by the UK Public Health Laboratory Service. No E. coli or pathogens were found. These results provide useful information for determination of microbiological hazards in school food service systems, and suggest that time-temperature control during delivery is necessary for the safety of cooked foods.

Temperature and diameter effect on hydrodynamic characteristic of surfactant drag-reducing flows

  • Indartono Y.S.;Usui H.;Suzuki H.;Komoda Y.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.157-164
    • /
    • 2005
  • Hydrodynamic characteristic of surfactant drag-reducing flows is still not fully understood. This work investigated the temperature and diameter effect on hydrodynamic characteristic of cationic surfactant drag reducing flows in pipes. Solution of oleyl bishydroxyethyl methyl ammonium chloride (Ethoquad O/12), 900 ppm, as a cationic surfactant and sodium salicylate (NaSal), 540 ppm, as a counter-ion was tested at 12, 25, 40, and $50^{\circ}C$ in pipes with diameter of 13, 25, and 40 mm. Drag reduction effectiveness of this surfactant solution was evaluated in 25 mm pipe from 6 to $75^{\circ}C$. Rheological characteristic of this solution was measured by stress control type rheometer with cone-and-plate geometry. Scale-up laws proposed by previous investigators were used to evaluate the flow characteristic of the solution. It was found that this surfactant solution has clear DR capability until $70^{\circ}C$. Result of this work suggested that temperature has a significant influence in changing the hydrodynamic entrance length of surfactant drag reducing flows. From rheological measurement, it was found that the solution exhibits Shear Induced Structure at all temperatures with different degree of peak viscosity and critical shear rate.

An Experimental Study on the Effects of Contact Angle on a Falling Liquid Film (접촉각이 유하액막 특성에 미치는 영향에 관한 실험적 연구)

  • Kim, Kyung-Hee;Kang, Byung-Ha;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.867-873
    • /
    • 2006
  • Vertical falling liquid film is extensively used in heat and mass transfer processes of many applications, such as evaporative coolers, cooling towers, and absorption chillers. In such cases, it is required that the falling film spreads widely in the surface forming thin liquid film to enlarge contact surface. An addition of surface active agent to a falling liquid film or hydrophilic surface treatment affects the fluid physical properties of the film. Surfactant addition not only decreases contact angle between the liquid and solid surface but also changes the surface from hydrophobicity to hydrophilicity. In this study, the effects of contact angle on falling film characteristics over a vertical surface have been investigated experimentally. The contact angle is varied either by an addition of surfactant to the liquid or by hydrophilic surface treatment. It is found that the wetted area is increased and film thickness is decreased by the hydrophilic treatment as compared with those of other surfaces. With this hydrophilic treatment, the falling liquid film spreads out widely in the surface. As surfactant concentration is increased, wetted area is also increased and the film thickness is substantially decreased.

A Study on the Noise Reduction of Reciprocating Type Air Compressors

  • Lee Kwang-Kil;Kim Kwang-Jong;Lee Gwan-Hyung;Park Jae-Suk;Son Doo-ik;Kim Bong-Ki;Lee Dong-Ju
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.6-9
    • /
    • 2004
  • This paper deals with the noise evaluation technique of a reciprocating air-compressor and its noise reduction. The reciprocating air-compressors are widely used in the small, medium sized industrial firms, and lots of their employees are affected and irritated by their noise in the workplace. Thus, noise control actions should be taken appropriately by considering the hearing loss due to the occupational noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving pistons, and flow-induced noise caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends etc .. As a result, main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10dB.

Experimental Study of the Effect of Side Plate on the Coanda Effect of Sonic Jet (측판이 음속 제트의 코안다 효과에 미치는 영향에 관한 실험적 연구)

  • Park, Sanghoon;Chang, Hongbeen;Lee, Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.24-30
    • /
    • 2016
  • An experimental study for the characteristics of the thrust-vectoring of a sonic jet utilizing the coanda flap installed at a rectangular nozzle exit is performed. Two side plates are installed at both sides of the flap to decrease the three dimensional effects of the jet on the flap surface. Schlieren flow visualizations and quantitative measurements of the deflection angle of thrusting vector show that the side plates are able to delay the separation of the jet at the downstream of the flap surface. Substantial increase in the deflection angle of the jet as high as $72^{\circ}$ and small thrust loss as low as 7% are obtained by the present thrust-vectoring technique using the side plates.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST (투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응)

  • Ahn Seok;Park Sang-Won;Yang Hong-So;Vang Mong-Sook;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

The Seasonal Microbiological Quality Assessment of Kimbap(seaweed roll) Production flow in Foodservice facilities for Univ. students - HACCP model - (대학생 대상 급식시설의 김밥 생산과정에 따른 계절별 미생물적 품질평가)

  • 이혜상;류승연
    • Korean journal of food and cookery science
    • /
    • v.14 no.4
    • /
    • pp.367-374
    • /
    • 1998
  • The purpose of this study was to evaluate the microbiological quality of, and to assure the hygienic safety of, the kimbap production in the university foodservice facilities in accordance with the HACCP (Hazard Analysis Critical Control Point) Program. The time-temperature relationship and the microbiological quality (specifically, total plate count and coliform bacteria count) were assessed to find the critical control point (CCP) during each of the production phases. The average of the daily longest duration time of the kimbap at the facilities was 23.4 hours in summer, while 29.6 hours in winter. In the purchasing phase of the raw materials, the microbiological quality of laver, fish paste, carrot and cucumber in summer was not at an acceptable level according to the standard set by the Natick research center, especially the number of TPC and the coliform level of laver was higher than the threshold level. In the refrigerator storage phase, the temperature of the carrot was 7.4$^{\circ}C$. This temperature is far exceeding the standard so that the microbiological counts was increased by the 2 log cycle during the average storage time of 17 hours or more. In the preparation phase, the temperature of the blanching is too low compared to the standard. In the holding phase before serving, its time-temperature relationship was out of the FDA food code standard both in winter and summer. In the sewing phase, the number of microbiological count was higher than the threshold level in summer while that in winter was up to standard. According to the Harrigan and McCance standard, the number of microbiological count of the utensils was higher than the threshold level in summer while that in winter was up to standard.

  • PDF

The Effect of Fluid Shear Stress on Endothelial Cell Adhesiveness to Modified Polyurethane Surfaces

  • Gilson Khang;Lee, Sang-Jin;Lee, Young-Moo;Lee, Jin-Ho;Lee, Hai-Bang q
    • Macromolecular Research
    • /
    • v.8 no.4
    • /
    • pp.179-185
    • /
    • 2000
  • Generally vascular grafts with a relatively large inner diameter (> 5 mm) have been successfully employed for replacement in the human body. However, the use of small diameter grafts is limited, because these grafts rapidly occlude due to the thrombosis. The ideal blood-contacting surface of a prosthesis would be an endothelial cell (EC) lining, because the confluent monolayer of healthy ECs that culture natural blood vessels represents the ideal nonthrombogenic surface. For vascular graft application, the stable EC adhesion on surface under How conditions is very important. In this study, the adhesive strength of ECs attached on polymer surfaces coated with collagen type IV (Col IV), fibronectin (Fn), laminin (Ln), and treated with corona was investigated onto polyurethane (PU) films. The EC-attached PU surfaces were mounted on parallel-plate flow chambers in a How system prepared for cell adhesiveness test. Three different shear stresses (100, 150, and 200 dyne/㎠) were applied to the How chambers and each shear stress was maintained for 120 min to investigate the effect of shear stress and surface treatment condition on the EC adhesion strength. It was observed that the EC adhesion strength on the surface-modified PU films was in the order of Ln≡Fn > Col IV > corona 》 control. More than 70% of the adhered cells were remained on surface-modified PU surface after applying the shear stress,200 dyne/㎠ for 2 hrs, whereas the cells were completely detached on the control PU surface within 10 min after applying the same shear stress. It seems that the type of adsorbed proteins and hydrophilicitv onto the PU surfaces play very important roles for cell adhesion strength.

  • PDF

Improvement of Boiler Performance on 550 MW Coal Fired Thermal Power Plant via Baffle Plates (다공판 연소가스 유량제어를 통한 석탄화력발전소 보일러 성능 개선)

  • Kim, Chi Ho;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.38-49
    • /
    • 2021
  • In order to increase power plant efficiency, the steam temperature was increased to 610 ℃ which deteriorates the durability of the boiler tube and as the use of low-calorie coal increases the post combustion and delayed combustion phenomenon, the overheating of the final reheater and the tube rupture are becoming frequent. In order to prevent overheating of the final reheater, desuperheater water injection was increased, leading to a decrease in boiler efficiency. In this study install a baffle plate at the back of some overheated tube groups, thereby reduce the temperature of the tube by reducing the amount of combustion gas, and the reduced combustion gas moves to an adjacent place to increase the temperature of other tubes. As a result of the study, the temperature deviation between tubes decreased 1.5. And the heat-reducing injection amount was reduced to 6,929 kg/h and the maximum tube temperature was reduced to 623.4℃ which is 6.6℃ more below than the control standard of 630℃.