• Title/Summary/Keyword: Flow channel design

Search Result 517, Processing Time 0.025 seconds

Numerical Study on Flow and Heat Transfer Enhancement in a Cooling Passage with Protrusion-In-Dimples (돌출부를 포함한 딤플 표면을 가진 냉각 유로에서의 유동과 열전달 성능 향상에 관한 수치적 연구)

  • Kim, Jeong-Eun;Ha, Man-Yeong;Yoon, Hyun-Sik;Doo, Jeong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.805-814
    • /
    • 2011
  • In the present study, the detailed flow structure and heat transfer characteristics in the newly-designed heat transfer surface geometry were investigated. The surface geometry proposed in the present study is a traditional dimple structure combining with a protrusion inside the dimple, which is named a protrusion-in-dimple in this study. The basic idea underlying the present surface geometry is to enhance the flow mixing and the corresponding heat transfer in the flow re-circulating region generated by a conventional dimple cavity. The present study was performed by the direct numerical simulation at a Reynolds number of 2800 based on mean velocity and channel height and Prandtl number of 0.71. Three different protrusion heights for protrusion-in-dimples were considered as the main design parameter of the present study. The calculated pressure drop and heat transfer capacity were assessed in terms of the Fanning friction factor and Colburn j factor. The overall performances estimated in terms of the volume and area goodness factor for protrusion-in-dimple cases were higher than the conventional dimple case.

Analysis of Flood Control Effect by Applying the Connecting Channel in Estuary Area Including the Confluence of Two Rivers (2개의 하천이 합류하는 하구역에서의 연결수로 통수능에 따른 홍수위저감효과 분석)

  • Kim, Sooyoung;Kim, Hyung-Jun;Yoon, Kwang Seok
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.12
    • /
    • pp.1065-1075
    • /
    • 2015
  • In the estuary where the structure such as river-mouth weir has been installed, the flow is developed very complicatedly due to river water from upstream, tide of the sea and floodgate operation. Especially, if basin outlets more than one exists in one estuary, the boundary conditions will be significantly more complex form. Saemangeum(SMG) project area in Korea is the most typical example. There are Mankyung river and Dongjin river in upstream. The water of them inflows into SMG project area. In the downstream, river flow was drained from inland to sea over the SMG sea dike through the sluice. The connecting channel was located between Mankyung and Dongjin basins. It functions not only as transportation by ship in ordinary period but also as flood sharing by sending flood flow to each other in flood period. Therefore, in order to secure the safety against flood, it is very important to understand the flood sharing capacity for connecting channel. In this study, the flood control effect was analyzed using numerical simulation. Delft3D was used to numerical simulation and simulated period was set up with neap tide, in which the maximum flood stage occurred due to poor drainage. Actually, three connecting channels were designed in land use plan of the SMG Master Plan, but they were simplified to a single channel for conciseness of analysis in this study. According to the results of numerical analysis, the water level difference between two basins was increased and the maximum flood stage at dike sluice was also upraised depending on decrease of conveyance. And the velocity induced by same water level difference was decreased when the conveyance became smaller. In certain conveyance above, there was almost no flood control effect. Therefore, if the results of this study are considered for design of connecting channel, it will be expected to draw the optimal conveyance for minimizing dredging construction cost while maximizing the flood control effect.

An Experimental Study on Heat Transfer Characteristics and Pressure Drop in Micro Plated Heat Exchangers with S-shape of Microchannel (S 형상의 마이크로 채널을 가진 마이크로 판형 열교환기의 열전달 특성 및 압력강하에 관한 실험적 연구)

  • Seo, Jang-Won;Kim, Yoon-Ho;Moon, Chung-Eun;Lee, Kyu-Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1876-1881
    • /
    • 2007
  • The micro plated heat exchangers were designed to transfer more heat/volume or mass than previous heat exchangers within the context of the design constraints specified. The increase of the surface-to-volume ratio results in an increase of the interfacial area. This enhances considerably the performance of a heat exchanger. This can be an important component in a wide range of applications fuel cell, aerospace, automotive, electronic system and home heating, etc). In this study, the performance evaluation of micro plated heat exchangers under the counter flows with straight and S-shaped channel are carried out. The pressure drop as well as inlet and outlet fluid temperature were measured at steady state under various operating conditions and the total heat transfer rate were also calculated.

  • PDF

FEM Analysis on Deformation Inhomogeneities Developed in Aluminum Sheets During Continuous Confined Strip Shearing (알루미늄 판재구속전단가공에서 형성되는 불균일 변형의 유한요소해석)

  • 최호준;이강노;황병복;허무영
    • Transactions of Materials Processing
    • /
    • v.12 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • The strain state during the continuous confined strip shearing (CCSS) based on ECAP was tackled by means of a two-dimensional FEM analysis. The deformation of AA 1100 sheet in the CCSS apparatus was composed of three distinct processes of rolling, bending and shearing. The pronounced difference in the friction conditions on the upper and lower roll surfaces led to the different variation of the strain component ${epsilon}_13$ throughout the thickness of the aluminum sheet. Strain accompanying bending was negligible because of a large radius of curvature. The shear deformation was concentrated at the corner of the CCSSchannel where the abrupt change in the direction of material flow occurred. The process variables involving the CCSS-die design and frictions between tools and strip influenced the evolution of shear strains during CCSS.

Design of Radio Resource Management System for WiBro MBS (WiBro 에서 MBS 서비스 제공을 위 한 무선자원관리 시스템 설계)

  • Tcha, Yong-Joo;Yum, Suk-Joon;Oh, Yun-Seok;Lee, Seong-Choon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.256-259
    • /
    • 2007
  • Multicast and Broadcast Service (MBS) provides flexible and efficient transmission of the same information to multiple users using shared radio resources on WiBro network. The advantage of this service is to achieve the most efficient use of radio and network resources as well as to lessen sender's processing load when sending the same information to multiple users. Though radio resources are saved since a multicast or broadcast transport connection is associated with a service flow, it is hard to change MBS service channel dynamically. In this paper, we propose a Radio Resource Management System (RRMS) for supporting dynamic scheduling of MBS service channels. Results show that our proposed scheme using Radio Resource Allocation Table (RRAT) can efficiently support MBS services by providing dynamic schedule for MBS service channels.

  • PDF

Investigation of Reducing Characteristics for the Spreading of Dredging Soil and the Diffusion of Contaminant by Silt Protector Curtain through Three Dimensional Numerical Model Experiment (3차원 수치모형실험을 통한 오탁방지막의 오염물질 및 준설토 확산 저감특성 조사)

  • Hong, Nam-Seeg
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.78-85
    • /
    • 2010
  • This study investigates reducing characteristics for the spreading of dredged soil and the diffusion of contaminant by silt protector curtain through three dimensional numerical experiment. The numerical medel is modified by combining the sediment transport characteristics for cohesive sediment into the previously developed model. Several numerical experiments have been given in order to investigate the reducing effect of silt protector using two dimensional numerical channel model under various parameters such as upstream flow velocity, depth of silt curtain and the position of dumped materials. Through the evaluation of several simulation results, we knew that the careful design has to be given in the determination of depth and position of silt protector.

Heat Transfer Analysis of a Pulse Magnetron Sputtering Cathode (펄스 마그네트론 스퍼터링 음극의 열전달 해석)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.6
    • /
    • pp.274-278
    • /
    • 2008
  • 3-dimensional numerical analysis for a rectangular magnetron cathode model is done to predict cooling characteristics of high power sputtering system for ZnO deposition. It includes cooling channel design, heat transfer analysis of a target, bonding layer and backing plate. In order to model erosion profiles of a target, ion current density distribution from 3D Monte Carlo simulation is used to distribute total sputtering power to 5 discrete regions. At 3 kW of sputtering power and cooling water flow of 1 liter/min at $10^{\circ}C$, the maximum surface temperature was $45.8^{\circ}C$ for a flat new target and $156^{\circ}C$ for a target eroded by 1/3 of its thickness, respectively.

Optimal Layout for Irrigation Pipeline Networks using Graph Theory (Graph 이론을 이용한 농업용 관수로망의 최적배치)

  • Im, Sang-Jun;Park, Seung-Woo;Cho, Jae-Pil
    • Journal of Korean Society of Rural Planning
    • /
    • v.6 no.2 s.12
    • /
    • pp.12-19
    • /
    • 2000
  • Irrigation pipeline networks consist mainly of buried pipes and are therefore relatively free from topographic constraints. Installation of irrigation pipeline systems is increasing since the systems have several advantages compared to open channel systems. To achieve economic design of pipeline networks, the layout should meet several conditions such as shortest path, maximum flow, and least cost. Graph theory is mathematical tool which enable to find out optimum layout for complicated network systems. In this study, applicability of graph theory to figure out optimum layout of irrigation pipeline networks was evaluated.

  • PDF

An Analysis on the Performance and the Heat Transfer of Molten Carbonate Fuel Cell Stack (용융탄산염 연료 전지 스택의 성능 및 열전달 해석)

  • Koo, J.Y.;Suh, J.C.;Kim, Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.120-129
    • /
    • 1994
  • A numerical investigation has been carried out for the electrochemical reaction, mass and heat transfer characteristics of the Molten Carbonate Fuel Cell(MCFC) stack. The effects of cooling air channel and water gas shift reaction were taken into account. The current density distribution of electrodes, the molecular fractions of reactant gasses and three dimensional temperature distribution can be calculated and shown by several lines of equivalent values. The results have been compared with the existing ones, and reasonable agreement has been obtained. To examine the influence of changing parameters, such as the composition of reactant gases, the target average current density, the utilization of reactant gases, the cooling air inlet temperature and flow rates, the computer simulation has been done. The analysis method and computer program developed in this study will be greatly helpful to design and verify the optimum operating condition of MCFC stack.

  • PDF

An Experimental Study on Heat Transfer Characteristics of Thermal Diode Type Enclosure Cavity (熱다이오식 밀폐공간의 熱傳達 特性에 關한 實驗的 硏究)

  • 장영근;김석현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1073-1080
    • /
    • 2000
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to density difference of fluid ,and blocks heat flow in the opposite direction. It is simple in construction and low in cost. And so, it is used as heat collection system of solar energy. In order to acquire a basic design data, thermal diode heat collection system has been studied experimentally for flux Rayleigh numbers from $2\times10^8\;to\;8\times10^8$. The heat transfer rate of this system is shown 10~47% higher than that of other earlier research results. He correlation obtained in this study is Nu=0.0037(Ra^*)^{0.429}(d^*)^{0.05}\frac{(Lr)}{H}^{0.415}$.

  • PDF