• 제목/요약/키워드: Flow Test

검색결과 6,482건 처리시간 0.035초

개구부 삽입부의 길이가 헬륨 및 공기의 치환류에 미치는 영향 (Effect of Opening Partition Length on Helium-Air Exchange Flow)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.192-200
    • /
    • 1999
  • This paper describes experimental investigations of helium-air exchange flow through parti-tioned opening. Such exchange flow may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with partitioned opening for parti-tion rations $H_p/H_1$ in the range 0 to 1 where $H_p$ and $H_1$ are partition length and height of the open-ing respecticely. In the case of $H_p/H_1$ of 0 flow passages of upward flow of the helium and down-ward flow of the air within the opening are unseparated (bidirectional) and the two flows interact exchange flow rate is minimum through range of the partition ratios, Two flow zones i.e. separat-ed(unidirectional)flow zone and unseparated(bidirectional) flow zone exist with increasing the partition. length, The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at $H_p/H_1$ of 1. As a result fo comparison of the exchange flow rates by changing the partition ration the fluids interaction in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

  • PDF

CATHARE simulation results of the natural circulation characterisation test of the PKL test facility

  • Salah, Anis Bousbia
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1446-1453
    • /
    • 2021
  • In the past, several experimental investigations aiming at characterizing the natural circulation (NC) behavior in test facilities were carried out. They showed a variety of flow patterns characterized by an inverted U-shape of the NC flow curve versus primary mass inventory. On the other hand, attempts to reproduce such curves using thermal-hydraulic system codes, showed 10-30% differences between the measured and calculated NC mass flow rate. Actually, the used computer codes are generally based upon nodalization using single U-tube representation. Such model may not allow getting accurate simulation of most of the NC phenomena occurring during such tests (like flow redistribution and flow reversal in some SG U-tubes). Simulations based on multi-U-tubes model, showed better agreement with the overall behavior, but remain unable to predict NC phenomena taking place in the steam generator (SG) during the experiment. In the current study, the CATHARE code is considered in order to assess a NC characterization test performed in the four loops PKL facility. For this purpose, four different SG nodalizations including, single and multi-U-tubes, 1D and 3D SG inlet/outlet zones are considered. In general, it is shown that the 1D and 3D models exhibit similar prediction results up to a certain point of the rising part of the inverted U-shape of the NC flow curve. After that, the results bifurcate with, on the one hand, a tendency of the 1D models to over-predict the measured NC mass flow rate and on the other hand, a tendency of the 3D models to under-predict the NC flow rate.

질소분사 음향시험을 통한 충돌형(FOOF) 분사기의 안정성 평가에 관한 연구 (Study on the Stability Test of Impinging(FOOF) Injector on $GN_2$ Purge Cold Flow Test)

  • 유덕근;이광진;서성현;한영민;최환석;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.135-140
    • /
    • 2006
  • 충돌형(FOOF) 분사기의 불안정 영역을 결정하기 위해 질소분사 음향시험을 수행하였다. 파이프와 오리피스 형상을 가지는 분사기 내 산화제 부분에서 유동속도에 비례하고, 비정상적으로 jumping하는 특정 주파수를 가지는 whistling이 발생한다. 동일한 조건의 연소시험과 비교해 본 결과 whistling 현상은 연소현상에는 영향을 주지 않는다. 질소분사 음향시험과 연소시험에서 얻은 연소실 내 1T1L mode의 damping factor를 비교하여 불안정 영역을 구해보면, 비슷한 조건에서 불안정 영역을 가진다. 이것은 유동의 충돌, 혼합에 의한 유동불안정 현상이 연소시험에서 연소불안정을 발생시키는 주요한 인자임을 의미 한다.

  • PDF

밸브 리프트 변화에 따른 실린더 내 흡입 공기의 유동 특성 (In -Cylinder Flow Characteristics Varying Intake Valve Lift)

  • 윤정의
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.82-88
    • /
    • 1999
  • The object of this study is to find new evaluation index for in-cylinder flow chracteristics istead of current swirl, tumble coefficient using steady flow test rig on intake port system. To this end, port flow system. To this end, port flow rig test was conducted on DOHC head varying intake valve lift respectively. Finally combination angular coefficient and inclination angle were introduced as new evaluation index for in-cylinder angularflow characteristics instead of swirl and tumble coefficient.

  • PDF

엔진 흡입포트 시스템 유동특성 규명을 위한 스월-텀블 합성효과에 관한 연구 (A Study on Combined Effects between Swirl and Tumble Flow of Intake Port System in Cylinder Head)

  • 윤정의
    • 한국자동차공학회논문집
    • /
    • 제7권8호
    • /
    • pp.76-82
    • /
    • 1999
  • The object of this study is to find new evalution index for in-cylinder flow characteristics insteady of current swirl, tumble coefficient using steady flow test rig on intake port system. To this end, port flow rig test was conducted on DOHC head varying intake valve lift respectively. Finally combination angular coefficient and inclination angle were introduced as new evaluation index for in-cylinder angular flow characteristics.

  • PDF

산업용 유량제어 송풍기 베인댐퍼 개발에 관한 연구 (A Study on Development of Vane Damper for Industry Flow Control Fan)

  • 이중섭;정인국;윤지훈;서정세;장성철
    • 한국생산제조학회지
    • /
    • 제21권1호
    • /
    • pp.137-143
    • /
    • 2012
  • In this study, it was conducted to design each components of vane damper for industrial flow control fan and the flow rates were analysed by experimental and numerical method. Through environmental test, it could be confirmed that the designed vane damper was appropriate. Also, almost identical results with test could be drawn from numerical method. Finally, flow rates of electric and pneumatic actuator were measured by test. As the results, difference of flow rate according to opening ratio was smaller in pneumatic actuator than that in electric actuator.

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

DBD 플라즈마 구동기를 이용한 2차원 모델의 플라즈마 유동제어 풍동시험 (Wind Tunnel Test of 2D Model for Plasma Flow Control using DBD Plasma Actuator)

  • 윤수환;김태규
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.527-528
    • /
    • 2012
  • 플라즈마 유동제어를 통한 공기저항저감을 위해 DBD(Dielectric Barrier Discharge) 플라즈마 구동기를 설계하였고, 2D 시험모델의 풍동시험을 통해 항력저감을 측정하였다. 풍속이 없는 경우에는 유동박리 및 표면마찰저항이 존재하지 않으므로 플라즈마 유동제어를 통한 항력저감도 없었다. 2m/s의 풍속에서 유동박리제어를 통해 항력이 9.7%까지 감소됨을 확인하였으며, 풍속이 증가할수록 항력저감은 감소하였다.

  • PDF

Critical Heat Flux and Flow Pattern for Water Flow in Annular Geometry

  • Park, Jae-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.224-229
    • /
    • 1996
  • An experimental study on critical heat flux (CHF) and two-phase flow visualization has been performed for water flow in internally-heated, vertical, concentric annuli under near atmospheric pressure. Tests have been done under stable forced- circulation, upward and downward flow conditions with three test sections of relatively large gap widths (heated length = 0.6 m. inner diameter = 19 mm, outer diameter = 29, 35 and 51 mm). The outer wall of the test section was made up of the transparent Pyrex tube to allow the observation of flow patterns near the CHF occurrence. The CHF mechanism was changed in the order of flooding, chum-to-annular flow transition, and local dryout under a large bubble in churn flow as the flow rate was increased from zero to higher values. Observed parametric trends are consistent with the previous understanding except that the CHF for downward flow is considerably lower than that for upward flow.

  • PDF

반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구 (A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip)

  • 이대규;마상범;김성;김정열;강채동;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제31권5호
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.