• 제목/요약/키워드: Flow Structures

검색결과 2,208건 처리시간 0.025초

시스템다이내믹스를 활용한 국내청소년 사이버불링피해 모델 개발 (Development of a Quantitative Model on Adolescent Cyberbullying Victims in Korea: A System Dynamics Approach)

  • 유미진;함은미
    • 대한간호학회지
    • /
    • 제49권4호
    • /
    • pp.398-410
    • /
    • 2019
  • Purpose: This study used a system dynamics methodology to identify correlation and nonlinear feedback structures among factors affecting adolescent cyberbullying victims (CV) in Korea and to construct and verify a simulation model. Methods: Factors affecting CV were identified by reviewing a theoretical background in existing literature and referencing various statistical data. Related variables were identified through content validity verification by an expert group, after which a causal loop diagram (CLD) was constructed based on the variables. A stock-flow diagram (SFD) using Vensim Professional 7.3 was used to establish a CV model. Results: Based on the literature review and expert verification, 22 variables associated with CV were identified and the CLD was prepared. Next, a model was developed by converting the CLD to an SFD. The simulation results showed that the variables such as negative emotions, stress levels, high levels of conflict in schools, parental monitoring, and time spent using new media had the strongest effects on CV. The model's validity was verified using equation check, sensitivity analysis for timestep and simulation with 4 CV adolescent. Conclusion: The system dynamics model constructed in this study can be used to develop intervention strategies in schools that are focused on counseling that can prevent cyberbullying and assist in the victims' recovery by formulating a feedback structure and capturing the dynamic changes observed in CV. To prevent cyberbullying, it is necessary to develop more effective strategies such as prevention education, counseling and treatment that considers factors pertaining to the individual, family, school, and media.

Decolorization of Acid Green 25 by Surface Display of CotA laccase on Bacillus subtilis Spores

  • Park, Jong-Hwa;Kim, Wooil;Lee, Yong-Suk;Kim, June-Hyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권9호
    • /
    • pp.1383-1390
    • /
    • 2019
  • In this study, we expressed cotA laccase from Bacillus subtilis on the surface of B. subtilis spores for efficient decolorization of synthetic dyes. The cotE, cotG, and cotY genes were used as anchoring motifs for efficient spore surface display of cotA laccase. Moreover, a $His_6$ tag was inserted at the C-terminal end of cotA for the immunological detection of the expressed fusion protein. Appropriate expression of the CotE-CotA (74 kDa), CotG-CotA (76 kDa), and CotY-CotA (73 kDa) fusion proteins was confirmed by western blot. We verified the surface expression of each fusion protein on B. subtilis spore by flow cytometry. The decoloration rates of Acid Green 25 (anthraquinone dye) for the recombinant DB104 (pSDJH-EA), DB104 (pSDJH-GA), DB104 (pSDJH-YA), and the control DB104 spores were 48.75%, 16.12%, 21.10%, and 9.96%, respectively. DB104 (pSDJH-EA) showed the highest decolorization of Acid Green 25 and was subsequently tested on other synthetic dyes with different structures. The decolorization rates of the DB104 (pSDJH-EA) spore for Acid Red 18 (azo dye) and indigo carmine (indigo dye) were 18.58% and 43.20%, respectively. The optimum temperature for the decolorization of Acid Green 25 by the DB104 (pSDJH-EA) spore was found to be $50^{\circ}C$. Upon treatment with known laccase inhibitors, including EDTA, SDS, and $NaN_3$, the decolorization rate of Acid Green 25 by the DB104 (pSDJH-EA) spore decreased by 23%, 80%, and 36%, respectively.

LES 난류모델을 이용한 초음속 증기 충돌제트의 과도하중 특성에 대한 수치해석 연구 (Numerical Analysis on the Transient Load Characteristics of Supersonic Steam Impinging Jet using LES Turbulence Model)

  • 오세홍;최대경;박원만;김원태;장윤석;최청열
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.77-87
    • /
    • 2018
  • In the case of high-energy line breaks in nuclear power plants, supersonic steam jet is formed due to the rapid depressurization. The steam jet can cause impingement load on the adjacent structures, piping systems and components. In order to secure the design integrity of the nuclear power plant, it is necessary to evaluate the load characteristics of the steam jet generated by high-energy pipe rupture. In the design process of nuclear power plant, jet impingement load evaluation was usually performed based on ANSI/ANS 58.2. However, U.S. NRC recently pointed out that ANSI/ANS 58.2 oversimplifies the jet behavior and that some assumptions are non-conservative. In addition, it is recommended that dynamic analysis techniques should be applied to consider transient load characteristics. Therefore, it is necessary to establish an evaluation methodology that can analyze the dynamic load characteristics of steam jet ejected when high energy pipe breaks. This research group has developed and validated the CFD analysis methodology to evaluate the transient behavior of supersonic impinging jet in the previous study. In this study, numerical study on the transient load characteristics of supersonic steam jet impingement was carried out and amplitude and frequency analysis of transient jet load was performed.

Will CFD ever Replace Wind Tunnels for Building Wind Simulations?

  • Phillips, Duncan A.;Soligo, Michael J.
    • 국제초고층학회논문집
    • /
    • 제8권2호
    • /
    • pp.107-116
    • /
    • 2019
  • The use of computational fluid dynamics (CFD) is becoming an increasingly popular means to model wind flows in and around buildings. The first published application of CFD to both indoor and outdoor building airflows was in the 1970's. Since then, CFD usage has expanded to include different aspects of building design. Wind tunnel testing (WTT) on buildings for wind loads goes back as far as 1908. Gustave Eiffel built a pair of wind tunnels in 1908 and 1912. Using these he published wind loads on an aircraft hangar in 1919 as cited in Hoerner (1965 - page 74). The second of these wind tunnels is still in use today for tests including building design ($Damljanovi{\acute{c}}$, 2012). The Empire State Building was tested in 1933 in smooth flow - see Baskaran (1993). The World Trade Center Twin Towers in New York City were wind tunnel tested in the mid-sixties for both wind loads, at Colorado State University (CSU) and the [US] National Physical Laboratory (NPL), as well as pedestrian level winds (PLW) at the University of Western Ontario (UWO) - Baskaran (1993). Since then, the understanding of the planetary boundary layer, recognition of the structures of turbulent wakes, instrumentation, methodologies and analysis have been continuously refined. There is a drive to replace WTT with computational methods, with the rationale that CFD is quicker, less expensive and gives more information and control to the architects. However, there is little information available to building owners and architects on the limitations of CFD for flows around buildings and communities. Hence building owners, developers, engineers and architects are not aware of the risks they incur by using CFD for different studies, traditionally conducted using wind tunnels. This paper will explain what needs to happen for CFD to replace wind tunnels. Ultimately, we anticipate the reader will come to the same conclusion that we have drawn: both WTT and CFD will continue to play important roles in building and infrastructure design. The most pressing challenge for the design and engineering community is to understand the strengths and limitations of each tool so that they can leverage and exploit the benefits that each offers while adhering to our moral and professional obligation to hold paramount the safety, health, and welfare of the public.

Effect of aerodynamic modifications on the surface pressure patterns of buildings using proper orthogonal decomposition

  • Tse, K.T.;Chen, Zeng-Shun;Lee, Dong-Eun;Kim, Bubryur
    • Wind and Structures
    • /
    • 제32권3호
    • /
    • pp.227-238
    • /
    • 2021
  • This study analyzed the pressure patterns and local pressure of tall buildings with corner modifications (recessed and chamfered corner) using wind tunnel tests and proper orthogonal decomposition (POD). POD can distinguish pressure patterns by POD mode and more dominant pressure patterns can be found according to the order of POD modes. Results show that both recessed and chamfered corners effectively reduced wind-induced responses. Additionally, unique effects were observed depending on the ratio of corner modification. Tall building models with recessed corners showed fluctuations in the approaching wind flow in the first POD mode and vortex shedding effects in the second POD mode. With large corner modification, energy distribution became small in the first POD mode, which shows that the effect of the first POD mode reduced. Among building models with chamfered corners, vortex shedding effects appeared in the first POD mode, except for the model with the highest ratio of corner modifications. The POD confirmed that both recessed and chamfered corners play a role in reducing vortex shedding effects, and the normalized power spectral density peak value of modes showing vortex shedding was smaller than that of the building model with a square section. Vortex shedding effects were observed on the front corner surfaces resulting from corner modification, as with the side surface. For buildings with recessed corners, the local pressure on corner surfaces was larger than that of side surfaces. Moreover, the average wind pressure was effectively reduced to 88.42% and 92.40% in RE1 on the windward surface and CH1 on the side surface, respectively.

디지털 데이터 중심의 AI기반 환경인지 생산기술 개발 방향 (Development of AI-based Cognitive Production Technology for Digital Datadriven Agriculture, Livestock Farming, and Fisheries)

  • 김세한
    • 전자통신동향분석
    • /
    • 제36권1호
    • /
    • pp.54-63
    • /
    • 2021
  • Since the recent COVID-19 pandemic, countries have been strengthening trade protection for their security, and the importance of securing strategic materials, such as food, is drawing attention. In addition to the cultural aspects, the global preference for food produced in Korea is increasing because of the Korean Wave. Thus, the Korean food industry can be developed into a high-value-added export food industry. Currently, Korea has a low self-sufficiency rate for foodstuffs apart from rice. Korea also suffers from problems arising from population decline, aging, rapid climate change, and various animal and plant diseases. It is necessary to develop technologies that can overcome the production structures highly dependent on the outside world of food and foster them into export-type system industries. The global agricultural industry-related technologies are actively being modified via data accumulation, e.g., environmental data, production information, and distribution and consumption information in climate and production facilities, and by actively expanding the introduction of the latest information and communication technologies such as big data and artificial intelligence. However, long-term research and investment should precede the field of living organisms. Compared to other industries, it is necessary to overcome poor production and labor environment investment efficiency in the food industry with respect to the production cost, equipment postmanagement, development tailored to the eye level of field workers, and service models suitable for production facilities of various sizes. This paper discusses the flow of domestic and international technologies that form the core issues of the site centered on the 4th Industrial Revolution in the field of agriculture, livestock, and fisheries. It also explains the environmental awareness production technologies centered on sustainable intelligence platforms that link climate change responses, optimization of energy costs, and mass production for unmanned production, distribution, and consumption using the unstructured data obtained based on detection and growth measurement data.

활성탄 흡착탑의 실용화를 위한 최적 유동특성 선정 및 열처리 조건에 따른 황화수소 포집능 향상 연구 (Investigation of Optimum Condition of Heat Treatment and Flow to Improve H2S Adsorption Capacity for Practical use of an Activated Carbon Tower)

  • 장영희;김봉환;김성수
    • 공업화학
    • /
    • 제32권1호
    • /
    • pp.91-96
    • /
    • 2021
  • 본 연구에서는 다양한 환경 공정에서 사용되는 황화수소 제거용 흡착탑 효율을 향상시키기 위해 유동 분석 및 흡착성능 향상 연구를 수행하였다. 연구를 위해 상업적으로 이용 가능한 다양한 활성탄에 칼륨(potassium, K)을 담지하여 개질 활성탄을 제조하였다. 또한 열처리 여부에 따라 흡착 성능과 열처리 과정에서 변화된 표면 특성 사이의 높은 상관관계를 고찰하고자 하였다. 함침법을 통해 K로 코팅된 활성탄은 57배 이상의 흡착 성능을 확인하였다. 이는 균일한 기공 형성과 탄소 표면의 K의 강한 결합은 황화수소의 화학적 및 물리적 흡수에 기여한다고 판단하였다. 다양한 상용 활성탄의 표면 구조에 대한 SEM 분석은 열처리를 통한 표면 특성의 변형으로 인해 기공 구조가 파괴되어 흡수 성능이 저하되는 것으로 확인하였다. 각 활성탄의 압력 손실 특성은 입자 크기와 모양에서 가장 낮은 압력 손실이 관찰되었다. 따라서 2~4 mesh 크기의 탄소입자 범위와 불규칙한 모양이 흡착탑의 성능을 향상시키고 경제적 효율성을 확보할 수 있다고 제안하였다.

분산전원이 연계된 배전선로의 운영시스템 설계 (Operation System Design of Distribution Feeder with Distributed Energy Resources)

  • 김성만;장영학;김경훈;김슬기;문채주
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1183-1194
    • /
    • 2021
  • 전통적으로 전력시스템은 공급체계의 말단에 있는 소비자의 위치에서 보면 중앙집중화된 구조를 갖고 있다. 그러나 최근 수 십년간 지붕형 태양광, 영농형 태양광, 소형 풍력터빈, 배터리저장장치 및 스마트 가전품과 같은 분산에너지원의 등장을 보아왔다. 분산에너지원의 등장에 따라 배전계통 운전원의 역할도 확장된다. 확장된 분산전원의 진출은 배전망이나 송전망의 전통적인 계획과 운영에 영향을 주는 전력계통의 역조류와 예측성을 어렵게 할 수 있다. 이는 전형적인 계통계획, 정비 및 망관리, 정전할당 등 배전계통 운전원이 갖는 기능이 변경되어야 할 필요성을 증폭시킨다. 이 연구의 목적은 다중 분산전원을 갖는 미래 배전운전시스템을 설계하고 제안된 배전시스템 모델을 HILS로 구현 및 검증하는 것이다. 시험결과를 보면 제안된 배전시스템이 정상 영역에서 운전되고 배전선로 손실이 감소된다는 것을 보여준다.

Modeling of heated concrete-filled steel tubes with steel fiber and tire rubber under axial compression

  • Sabetifar, Hassan;Nematzadeh, Mahdi;Gholampour, Aliakbar
    • Computers and Concrete
    • /
    • 제29권1호
    • /
    • pp.15-29
    • /
    • 2022
  • Concrete-filled steel tubes (CFSTs) are increasingly used as composite sections in structures owing to their excellent load bearing capacity. Therefore, predicting the mechanical behavior of CFST sections under axial compression loading is vital for design purposes. This paper presents the first study on the nonlinear analysis of heated CFSTs with high-strength concrete core containing steel fiber and waste tire rubber under axial compression loading. CFSTs had steel fibers with 0, 1, and 1.5% volume fractions and 0, 5, and 10% rubber particles as sand alternative material. They were subjected to 20, 250, 500, and 750℃ temperatures. Using flow rule and analytical analysis, a model is developed to predict the load bearing capacity of steel tube, and hoop strain-axial strain relationship, and axial stress-volumetric strain relationship of CFSTs. An elastic-plastic analysis method is applied to determine the axial and hoop stresses of the steel tube, considering elastic, yield, and strain hardening stages of steel in its stress-strain curve. The axial stress in the concrete core is determined as the difference between the total experimental axial stress and the axial stress of steel tube obtained from modeling. The results show that steel tube in CFSTs under 750℃ exhibits a higher load bearing contribution compared to those under 20, 250, and 500℃. It is also found that the ratio of load bearing capacity of steel tube at peak point to the load bearing capacity of CFST at peak load is noticeable such that this ratio is in the ranges of 0.21-0.33 and 0.31-0.38 for the CFST specimens with a steel tube thickness of 2 and 3.5 mm, respectively. In addition, after the steel tube yielding, the load bearing capacity of the tube decreases due to the reduction of its axial stiffness and the increase of hoop strain rate, which is in the range of about 20 to 40%.

Spatial correlation of aerodynamic forces on 5:1 rectangular cylinder in different VIV stages

  • Lei, Yongfu;Sun, Yanguo;Zhang, Tianyi;Yang, Xiongwei;Li, Mingshui
    • Wind and Structures
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2022
  • To better understand the vortex-induced vibration (VIV) characteristics of a 5:1 rectangular cylinder, the distribution of aerodynamic force and the non-dimensional power spectral density (PSD) of fluctuating pressure on the side surface were studied in different VIV development stages, and their differences in the stationary state and vibration stages were analyzed. The spanwise and streamwise correlations of surface pressures were studied, and the flow field structure partitions on the side surface were defined based on the streamwise correlation analysis. The results show that the variation tendencies of mean and root mean square (RMS) pressure coefficients are similar in different VIV development stages. The RMS values during amplitude growth are larger than those at peak amplitude, and the smallest RMS values are observed in the stationary state. The spanwise correlation coefficients of aerodynamic lifts increase with increase of the peak amplitude. However, for the lock-in region, the maximum spanwise correlation coefficient for aerodynamic lifts occurs in the VIV rising stage rather than in the peak amplitude stage, probably due to the interaction of vortex shedding force (VSF) and self-excited force (SEF). The streamwise correlation results show that the demarcation point positions between the recirculation region and the main vortex region remain almost constant in different VIV development stages, and the reattachment points gradually move to the tailing edge with increasing amplitude. This study provides a reference to estimate the demarcation point and reattachment point positions through streamwise correlation and phase angle analysis from wind tunnel tests.