• Title/Summary/Keyword: Flow Resonance

Search Result 477, Processing Time 0.023 seconds

Diagnostic Imaging of Biliary Atresia (담도폐쇄증의 영상 진단)

  • Haesung Yoon;Hyun Ji Lim;Jisoo Kim;Mi-Jung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.991-1002
    • /
    • 2022
  • Biliary atresia is a rare but significant cause of neonatal cholestasis. An early and accurate diagnosis is important for proper management and prognosis. To diagnose biliary atresia, various imaging studies using ultrasonography, MRI, hepatobiliary scans, and cholangiography can be performed, although ultrasonography is more important for initial imaging studies. In this article, we review the findings of biliary atresia from various imaging modalities, including ultrasonography, MRI, hepatobiliary scans, and cholangiography. The known key imaging features include abnormal gallbladder size and shape, periportal thickening visible as a 'triangular cord' sign, invisible common bile duct, increased hepatic arterial flow, and combined anomalies. Aside from the imaging findings of biliary atresia, we also reviewed the diagnostic difficulty in the early neonatal period and the role of imaging in predicting hepatic fibrosis. We hope that this review will aid in the diagnosis of biliary atresia.

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.

Postoperative Imaging Findings of Biliary Atresia (담도폐쇄증의 수술 후 영상 소견)

  • Jisun Hwang;Hee Mang Yoon;Pyeong Hwa Kim;Jung-Man Namgoong;Seak Hee Oh;Ah Young Jung;Jin Seong Lee;Young Ah Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1014-1031
    • /
    • 2022
  • The Kasai portoenterostomy is the first-line treatment for the restoration of the flow of bile to the small intestine in patients with biliary atresia. Various complications can occur after Kasai portoenterostomy, including ascending cholangitis, biliary cirrhosis, and portal hypertension. Of these potential complications, ascending cholangitis in the most common. In cases of patients having uncontrolled complications due to progressive liver cirrhosis, portal hypertension, or progressive hyperbilirubinemia, liver transplantation is the indicated as treatment plan. Lifelong follow-up, particularly involving imaging studies, is important for the identification of various complications arising from biliary atresia after Kasai portoenterostomy. Additionally, imaging studies play a crucial role in the evaluation of potential liver donors and recipients. US is a key imaging modality utilized in the management of patients who undergo Kasai portoenterostomy, while CT and MRI are imperative to obtaining an accurate diagnosis.

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

The Study of anti-cancer mechanism with Cobrotoxin on Human prostatic cancer cell line(PC-3) (전립선 암세포에 대한 Cobrotoxin의 항암(抗癌) 기전(機轉) 연구(硏究))

  • Chae, Sang-jin;Song, Ho-seup
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.169-183
    • /
    • 2005
  • Objective : The purpose of this study was to investigate the anti-caner effect of cobrotoxin on the prostatic cancer cell line (PC-3).The goal of study is to ascertain whether cobrotoxin inhibits tile cell growth and cell cycle of PC-3, or the expression of relative genes and whether the regression of PC-3 cell growth is due to cell death or the expression of gene related to apoptosis. Methods : After the treatment of Pc-3 cells with cobrotoxin, we performed 형광현미경, MTT assay, Western blotting, Flow cytometry, PAGE electrophoresis and Surface plasmon resonance analysis to identify the cell viability, cell death, apoptosis, the changes of cell cycle and the related protein, Adk, MAP kinase. Results : 1. Compared with normal cell, the inhibition of cell growth reduced in proportion with the dose of cobrotoxin(0-16nM) in PC-3. 2. Cell viabilities of 0.1, 1, 4nM cobrotoxin treatment were decreased and those of 8, 16nM were decreased significantly. 3. S phase of cell cycle was decreased at the group of 1, 2, 4, 8, 16nM cobrotoxin, but M phase was increased at 0.1, 1, 2, 4, 8, 16nM cobrotoxin. 4. Cox-2 expression after cobrotoxin was peaked at 12hours and was decreased significantly after 6, 12, 24 hours. 5. The expression of Cdk4 was decreased dose-dependently at 1, 2, 4, 8nM cobrotoxin and was decreased siginificantly at 4, 8nM Cyclin D1 was decreased at 1, 2, 4, 8nM and Cycline E was not changed. Cycline B was decreased at 1, 2, 4, 8nM dose-dependently and was decreased siginificanlty at 2, 4, 8nM. 6. The expression of Akt was decreased at 1, 2, 4, 8nM dose-dependently and was decreased significantly at 2, 4, 8nM. 7. ERK was increased at 1, 2nM and decreased at 4, 8nM, p-ERK was increased at 1, 2, 4 nM, but decreased at 8nM. JNK and p-JNK were increased at 1, 4, 8 nM. p38 was increased at 2nM p-p38 was increased at lnM but decreased significantly at 2, 4, 8nM. 8. The nucli of normal cells were stained round and homogenous in DAPI staining, but those of PC-3 were stained condense and splitted. Apoptosis was increased dose-dependently at 2, 4, 8, 16nM and increased significantly at 2, 4, 8, 16nM. 9. Bax wasn`t changed at 1, 2, 4, 8nM and Bcl-2 was decreased significantly at 1, 2, 4, 8nM. Caspase 3 and 9 weren`t changed at 1, 2, 4nM but were decreased significantly at 8nM. Conclusions : These results indicate that cobrotoxin inhibits the growth of prostate Cancer cells, has anti-cancer effects by inducing apoptosis.

  • PDF