• Title/Summary/Keyword: Flow Pump System

Search Result 877, Processing Time 0.023 seconds

Concrete plug cutting using abrasive waterjet in the disposal research tunnel (연마재 워터젯을 활용한 처분터널 내 콘크리트 플러그 절삭)

  • Cha, Yohan;Kim, Geon Young;Hong, Eun-Soo;Jun, Hyung-Woo;Lee, Hang-Lo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.153-170
    • /
    • 2022
  • Waterjet has been comprehensively used in urban areas owing to a suitable technique for cutting concrete and rock, and low noise and vibration. Recently, the abrasive waterjet technique has been adopted and applied by the Korea Atomic Energy Research Institute to demolish concrete plugging without disturbing and damaging In-situ Demonstration of Engineered Barrier System in the disposal research tunnel. In this study, the use of abrasive waterjet in the tunnel was evaluated for practical applicability and the existing cutting model was compared with the experimental results. As a variable for waterjet cutting, multi-cutting, water flow rate, abrasive flow rate, and standoff distance were selected for the diversity of analysis. As regarding the practical application, the waterjet facilitated path selection for cutting the concrete plugging and prevented additional disturbances in the periphery. The pump's noise at idling was 64.9 dB which is satisfied with the noise regulatory standard, but it exceeded the standard at ejection to air and target concrete because the experiment was performed in the tunnel space. The experimental result showed that the error between the predicted and measured cutting volume was 12~13% for the first cut and 16% for second cut. The standoff distance had a significant influence on the cutting depth and width, and the error tended to decrease with decrement of standoff distance.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Multivessel Coronary Revascularization with Composite LITA-RA Y Graft (좌내흉동맥-요골동맥 복합이식편을 이용한 다중혈관 관상동맥우회술)

  • Lee Sub;Ko Mgo-Sung;Park Ki-Sung;Ryu Jae-Kean;Jang Jae-Suk;Kwon Oh-Choon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.359-365
    • /
    • 2006
  • Background: Arterial grafts have been used to achieve better long-term results for coronary revascularization. Bilateral internal thoracic artery (ITA) grafts have a better results, but it may be not used in some situations such as diabetes and chronic obstructive pulmonary disease (COPD). We evaluated the clinical and angiographic results of composite left internal thoracic artery-radial artery (LITA-RA) Y graft. Material and Method: Between April 2002 and September 2004, 119 patients were enrolled in composite Y graft for coronary bypass surgery. The mean age was $62.6{\pm}8.8$ years old and female was 34.5%. Preoperative cardiac risk factors were as follows: hypertension 43.7%, diabetes 33.6%, smoker 41.2%, and hyperlipidemia 22.7%, There were emergency operation (14), cardiogenic shock (6), left ventricle ejection fraction (LVEF) less than 40% (17), and 17 cases of left main disease. Coronary angiography was done in 35 patients before the hospital discharge. Result: The number of distal anastomoses was $3.1{\pm}0.91$ and three patients (2.52%) died during hospital stay. The off-pump coronary artery bypass (OPCAB) was applied to 79 patients (66.4%). The LITA was anastomosed to left anterior descending system except three cases which was to lateral wall. The radial Y grafts were anastomosed to diagonal branches (4), ramus intermedius (21), obtuse marginal branches (109), posterolateral branches (12), and posterior descending coronary artery (8). Postoperative coronary angiography in 35 patients showed excellent patency rates (LITA 100%, and RA 88.5%; 3 RA grafts which anastomosed to coronary arteries <70% stenosed showed string sign with competitive flow). Conclusion: The LITA-RA Y composite graft provided good early clinical and angiographic results in multivessel coronary revascularization. But it should be cautiously used in selected patients.

Quantitative Analysis of Ergosterol as a Biomarker of Mold-contaminated Foods Using the Enzyme Biosensor (효소 바이오센서를 이용한 식품의 곰팡이 오염 지표물질인 Ergosterol 정량분석)

  • Kim, Mi-Kyeong;Kim, Jong-Won;Kim, Mee-Ra
    • Korean journal of food and cookery science
    • /
    • v.25 no.2
    • /
    • pp.252-259
    • /
    • 2009
  • Ergosterol is the significant component of the cell wall of fungi. Its presence is regarded as evidence of fungi contamination in grain and other foods. Many studies on ergosterol detection have been carried out using chemical methods, but those methods required complicated pre-treatments and long analysis times. In this study, an amperometric biosensor was developed for fast and precise ergosterol detection. The biosensor system used the electron transfer of hydrogen peroxide produced from the reaction of ergosterol with cholesterol oxidase. The biosensor system consisted of a peristaltic pump, a syringe loading sample injector, an enzyme reactor, a fabricated flow-through cell containing a working electrode, a reference electrode and a counter electrode, and a potentiostat/recorder. The working electrode was prepared by coating modified multi-wall carbon nanotube (MWNT) on glassy carbon electrode. The $MWNT-NH_2$ coated glassy carbon electrode linearly responded to hydrogen peroxide in the range of $1{\times}10^{-5}{\sim}8{\times}10^{-5}$ M with a detection limit of $10^{-7}$ M in the basic performance test. The currents produced from the ergosterol biosensor showed the linearity in a range from $1.0{\times}10^{-6}$ M to $1.0{\times}10^{-5}$ M ergosterol.

Basic Design of 36 MTD Class Natural Gas BOG Re-Liquefaction System (36 MTD급 천연가스 BOG 재액화 플랜트 기본설계)

  • Ko, Junseok;Park, Seong-Je;Kim, Ki-Duck;Hong, Yong-Ju;Koh, Deuk-Yong;Kim, Hyobong;Yeom, Hankil
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.99-105
    • /
    • 2013
  • In this paper, we carried out the basic design of 36 MTD natural gas BOG re-liquefaction system to recover the generated natural gas during performance test of LNG pump and natural gas compressor. The re-liquefaction process of natural gas is designed to have 1500 kg/h of liquefaction rate with reverse Brayton refrigeration cycle. With the designed process, the variation of liquefaction rate is calculated for various inlet conditions of feed gas. From results, the liquefaction rate is more sensitive for inlet temperature than gas composition. The specifications of equipments such as gas blower, natural gas compressor, cryogenic heat exchanger and nitrogen compander are determined on the basis of the designed process. The requirement of power consumption and cooling water are also determined through the basic design.

The In-hospital Clinical Outcomes of Extracorporeal Life Support after Adult Cardiovascular Surgery (성인 심혈관 수술 후 시행한 체외순환보조의 조기 임상결과)

  • Yie, Kil-Soo;Na, Chan-Young;Oh, Sam-Sae;Kim, Jae-Hyun;Ryu, Se-Min;Park, Sung-Min;Cho, Seong-Joon
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.464-472
    • /
    • 2009
  • Background: We analyzed the clinical results and the factors for survival of patients who underwent extracorporeal life support system after adult cardiovascular surgery. Material and Method: We retrospectively reviewed the medical record of 44 patients (1.6% of the total adult cardiovascular surgical cases) who underwent the use of a ventricular assisted device or extracorporeal membrane oxygenation from January 2002 to August 2008. There were 32 (72.7%) males and their mean age was 61.7$\pm$14.9(range: 20$\sim$73) years old. The mean duration of extracorporeal life support system was 5.3$\pm$3.0 (range: 1$\sim$12) days. Result: Of these 44 patients, 24 (54.5%) patients were successfully weaned from the extracorporeal device. Eighteen (40.9%) survivors were able to be discharged from the hospital. Complications were noted in 38 patients (86.4%). An emergency operation, no usage of a concomitant intraaortic balloon pump and major complications during use of the extra corporeal life support system such as bleeding, flow instability and renal failure were identified as significant risk factors for poor survival on univariated analysis. Owing to educational support and a continuous renal replacement therapy system, the clinical outcomes of these patients have improved since 2006. On multivariated analysis, renal failure and bleeding during extracorporeal life support were significant risk factors for poor survival. Conclusion: Although using. extracorporeal life support systems after adult cardiovascular surgery revealed acceptable clinical results, determining the optimal treatment strategy and further well designed larger studies are needed to improve the survival rate of patients who undergo extracorporeal life support after adult cardiovascular surgery.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Deep Sedation for Palate Alginate Impression Procedure in a Post-Fontan Procedure Patient with Mental Retardation (Fontan 수술을 받은 정신지체 소아에서 인상채득을 위해 시행한 깊은 진정)

  • Lee, Jung-Man;Seo, Kwang-Suk;Kim, Hyun-Jeong;Shin, Soon-Young;Shin, Teo-Jeon
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • The Fontan operation is a heart operation used to treat complex congenital heart defects like tricuspid atresia, hypoplastic left heart syndrome, pulmonary atresia and single ventricle. A single ventricle is dedicated to pumping oxygenated blood to the systemic circulation and the entire systemic venous return reaches the pulmonary arterial system without the direct influence of a pumping chamber. In the patient with Fontan operation, it is important to achieve adequate pulmonary blood flow and cardiac output in anesthetic management. In this case, a 10-year-old boy (19.6 kg, 114 cm) with cleft palate, cerebral palsy and severe mental retardation, who underwent a Fontan operation when he was 4 years old, was presented for deep sedation. Because he was suffering from eating disorder with cleft palate, the orthodontist and the plastic surgeon planned to insert intraoral orthodontic device before cleft palate repair. But it was impossible to open his mouth for alginate impression procedure. After careful pre-anesthesia evaluation we planned to administer deep sedation with propofol infusion. After Intravenous catheter insertion, we started propofol intravenous infusion with the formula of a loading dose of 1.0 mg/kg followed by an infusion rate of 6.0 mg/kg/hr with syringe pump. His blood pressure was remained around 80/40 mmHg after loss of consciousness, but he could not maintain his airway patent. So we lowered the infusion rate to 3.0 mg/kg/hr, immediately. The oxygen saturation was maintained above 95% with nasal oxygen supply, and blood pressure was maintained around 100-80/60-40 mmHg. After the sedation of 110 minutes with propofol (the infusion rate to 3.0-5.0 mg/kg/hr), he fully regained consciousness, and was discharged without complication after 1 hour observation. In case of post-Fontan patient, intravenous deep sedation with propofol was safe and effective method of behavioral management during dental treatment.

A Study on the Thermal Characteristics of Jeju type Ground Heat Exchanger for Ground Source Heat Pump System applied to Jeju Island (제주도에 설치된 지열 열펌프 시스템용 제주형 지중열교환기의 열특성 연구)

  • Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).

Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases- (선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) -)

  • Kim, Kun Ho;Park, Young Kwan;Jee, Heng Ok;Kim, Young Tae;Rhee, Chong Bae;Chung, Yun Chae;Oh, Chull Soo
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF