This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).
Keywords
Ground Temperature; Thermal Characteristics; Ground Heat Exchangers; Groundwater Level; Borehole;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M. J. Kim, A Study on the Thermal Performance Evaluation of a Borehole Ground Heat Exchange using In-Situ Thermal Response Test, Ph.D thesis, Sunmoon University, Korea, 2017. http://www.riss.kr/link?id=T14447807
2 Ministry of Trade, Industry and Energy Announcement 2015-263, Standards of Support, Installation and Management for New and Renewable Energy System, 2015.
3 G. W. GO, "Groundwater characteristic and water resources management in jeju(ii) - Jeju groundwater hydrogeological characteristics", Magazine of korea water resources association, Vol.39, No.8, pp.80-89, 2006. http://www.riss.kr/link?id=A100588177
4 Jeju special self-governing province ground water management ordinance, Jeju special self-governing province ground water management ordinance enforcement regulations, Appendix 5, 2017.
5 Chang, K.S. and Kim, M.J., "An experimental study on the thermal performance evaluation of SCW ground heat exchanger", International Journal of Air-Conditioning and Refrigeration, Vol.25, No.1, 2017. DOI: https://doi.org/10.1142/S2010132517500067