• 제목/요약/키워드: Flow Non-uniformity

검색결과 106건 처리시간 0.024초

반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향 (Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process)

  • 박준수;권현구;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

디퓨저 타입 레큐퍼레이터 헤더에서 유동분배에 미치는 베인의 영향 (Effect of Vanes on Flow Distribution in a Diffuser Type Recuperator Header)

  • 정영준;김서영;김광호;곽재수;강병하
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.819-825
    • /
    • 2006
  • In a SOFC/GT (solid oxide fuel cell/gas turbine) hybrid power generation system, the recuperator is an indispensible component to enhance system performance. Since the expansion ratio to the recuperator core is very large, generally, the effective header design to distribute the flow uniformly before entering the core is crucial to guarantee the required performance. In the present study, we focus on the design of a diffuser type recuperator header with a 90 degree turn inlet port. To reduce the flow separation and recirculation flows, multiple horizontal vanes are used. The number of horizontal vanes is varied from 0 to 24. The air flow velocity is measured at 40 points just behind the core outlet by using a hot wire anemometer. Then, the flow non-uniformity is evaluated from the measured flow velocity. The experimental results showed that inlet air velocity did not effect on relative flow non-uniformity. According to increasing the number of horizontal vanes, flow non-uniformity reduced about $40{\sim}50%$ than without using horizontal vanes.

Focus Ring 재질과 두께변경에 따른 Rnit non uniformity 평가 (Rnit non uniformity evaluation by materials and thickness of focus ring)

  • 차성호;정진욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2153-2155
    • /
    • 2005
  • SF6 &NF3 chemistry를 사용하여 W bitline process 조건에서 plasma confinement 및 gas & radical의 flow에 영향을 미치는 focus ring 재질과 두께변경을 하여 Rnit non uniformity 평가한다.

  • PDF

PIV를 이용한 Chemical Mechanical Polishing 공정 중의 연마용액 유동흐름 측정 (Visualization of the Slurry Flow-Field during Chemical Mechanical Polishing by PIV)

  • 신상희;김문기;윤영빈;고영호
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.48-51
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) is popularly used in production of semiconductor because of large area polishing ability probability of improvement for more integrated circuit. However, present CMP processing causes some non-uniformity errors which can be critical for highly integrated circuit. Previous studies predict that flow-field of slurry during CMP can create non-uniformity, but no quantitative measurement has conducted. In this study, using PIV, slurry velocity flow-field during CMP is measured by changing the ratio of RPM of pad and carrier with tuned PIV system adequate for small room in CMP machine and Cabot's non-groove pad Epad-A100. The result show that velocity of slurry is majorly determined by pad-rpm and the ratio of between carrier and pad rpm make some changes in streamlines.

  • PDF

배출물 저감을 위한 촉매변환기 내의 3차원 유동해석 (Three-Dimensional Flow Analysis of Catalytic Converter for Reducing Emission)

  • 정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.55-65
    • /
    • 1998
  • A numerical and experimental study of three-dimensional steady incompressible non-reacting flow inside various dual-monolith catalytic converters has been conducted for achievement of performance improvement, reduction of light-off time and longer service life by improving the flow uniformity within the monolith. In this study, the effects of curvature of inlet exhaust pipe and monolith brick length on the flow uniformity and pressure drop within monolith were numerically investigated. The computations are confirmed by measurements of steady flow. The agreement between computations and experiment was relatively good. The result of this study shows that curvature of inlet exhaust pipe and monolith brick length gave a great effect on the flow uniformity and the shorter the brick length, the lower flow uniformity and the less pressure drop.

  • PDF

Flow Analysis of the Spin Coating Machine

  • Ha, Man-Yeong;Kang, Dong-Hoon;Jeong, Bong-Kyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1147-1150
    • /
    • 2003
  • When a braun tube becomes wider, one of the major problems to be experienced is the non-uniform coating along the four diagonal directions on its surface. This non-uniformity in the coating thickness has a deep relation with the fluid flow on the surface of a braun tube. In order to control the fluid flow properly, we install the plate to block fluid flow at the corner of a braun tube. In the present study, we investigate the effects of the geometry of plate to control the fluid flow and coating uniformity and determine the optimal shape of plate to improve the quality of coating uniformity.

  • PDF

엔진룸내 방열기 전단면 유동 불균일도 측정에 관한 연구 (Experimental Study of the Non-Uniform Mean Flow at the Front of a Radiator in Engine Room)

  • 류명석
    • 한국자동차공학회논문집
    • /
    • 제4권4호
    • /
    • pp.72-79
    • /
    • 1996
  • The recent trend of higher output engines with more auxiliary parts is resulting in greater heat generation in the engine compartment. In order to maximize the heat dissipation and eliminate the inefficient flow in the engine compartment, it is necessary to understand the flow field under the hood. In this respect, experimental study as well as numerical analysis should be conducted. The automated measuring system was constructed to obtain three dimensional mean flow data with high accuracy. The measurements have been made on a vehicle with a steady incoming air flow. The result shows that there exists a high degree of non-uniformity in the mean flow velocity at the front of radiator.

  • PDF

중형 차량 엔진룸에서의 유동해석에 관한 연구 (Study of Flow Analysis of a Mid-size Vehicle in an Engine Room)

  • 이동렬
    • 한국전산유체공학회지
    • /
    • 제9권4호
    • /
    • pp.13-19
    • /
    • 2004
  • Flow distribution of a mid-size vehicle in engine room was investigated numerically to analyze the flow performance of given design cases in a front body of the mid-size vehicle. The data analyzed are the mass flow rate at the upper and lower openings, in the radiator, and the degree of non-uniformity of the velocity field at the inlet of the radiator. It is presented that the shape of the front end and the presence of the undercover greatly affect the flow fields, therefore, the flow performance.

SiH$_4$-H$_2$계에서 유체유동이 Si의 화학증착에 미치는 영향 (Effects of Flow on the Chemical Vapor Deposition of Si in System SiH$_4$-H$_2$)

  • 조성욱;이경우;조영환;윤종규
    • 한국표면공학회지
    • /
    • 제23권3호
    • /
    • pp.160-166
    • /
    • 1990
  • The effects of the variation of proedd varibles on the flow patterns and effects of the flow patterns on the deposition rate and uniformity in the Si-epitaxy CVD with SiH4 as the source of Si were studied through the calculation by use of control volume method. The reslts showed that the natural convection was undesirable to the uniformity of deposition rate, whose effects were decreased with the dercrese with the decrese of the pressure in the reactoor and with the increase of the flow rate. However. the excessive increase of flow rate caused the movement of the unreacted gas to the substrate. Therefore it resulted in the non-uniform depositions. The rotation of substrate was apperared to improve the uniformity. The resulte of this study could used in CVD process to design the reator and to find the optimum conditions of the process variables.

  • PDF

슬릿 노즐 내부 압력 분포와 코팅 박막 두께 균일도 간의 상관관계 연구 (Study on Correlation Between the Internal Pressure Distribution of Slit Nozzle and Thickness Uniformity of Slit-coated Thin Films)

  • 김기은;나정필;정모세;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.19-25
    • /
    • 2023
  • With an attempt to investigate the correlation between the internal pressure distribution of slit nozzle and the thickness uniformity of slot-coated thin films, we have performed computational fluid dynamics (CFD) simulations of slit nozzles and slot coating of high-viscosity (4,800 cPs) polydimethylsiloxane (PDMS) using a gantry slot-die coater. We have calculated the coefficient of variation (CV) to quantify the pressure and velocity distributions inside the slit nozzle and the thickness non-uniformity of slot-coated PDMS films. The pressure distribution inside the cavity and the velocity distribution at the outlet are analyzed by varying the shim thickness and flow rate. We have shown that the cavity pressure uniformity and film thickness uniformity are enhanced by reducing the shim thickness. It is addressed that the CV value of the cavity pressure that can ensure the thickness non-uniformity of less than 5% is equal to and less than 1%, which is achievable with the shim thickness of 150 ㎛. It is also found that as the flow rate increases, the average cavity pressure is increased with the CV value of the pressure unchanged and the maximum coating speed is increased. As the shim thickness is reduced, however, the maximum coating speed and flow rate decrease. The highly uniform PDMS films shows the tensile strain as high as 180%, which can be used as a stretchable substrate.

  • PDF