• 제목/요약/키워드: Flow Measuring

검색결과 1,323건 처리시간 0.038초

선택적 촉매 환원법을 위한 외부 혼합형 이유체 노즐 개발에 대한 실험적 연구 (Development of an external twin-fluid nozzle for Selective Catalytic Reduction)

  • 박정근;이충원
    • 한국분무공학회지
    • /
    • 제9권2호
    • /
    • pp.24-33
    • /
    • 2004
  • The effect of the working fluid flow conditions and nozzle geometry on the spray performance of a twin-fluid nozzle used in Selective Catalytic Reduction is investigated experimentally. The liquid pressure is varied in the range of 0.3atm to 1.5atm and the air pressure is varied from the 0.5atm to 3.0atm. relative position between liquid nozzle(internal nozzle) and air nozzle(external nozzle) tip changes front 1mm inside the air nozzle to 1mm outside the air nozzle. The orifice diameter of the air nozzle is varied with 5mm. 6mm and 7mm. Spray visualization is realized with CCD-Camera. SMD(Sauter Mean Diameter) and mean particle velocities are measured by PDPA(Phase Doppler Particle Analyzer) under various experimental conditions. The measuring point is 300mm away from the nozzle tip in the downstream spray. The experimental results are that spray angle is depended air flow rate because nozzle diameter, air pressure and nozzle tip relative positions are related air flow rate. SMD is depended air flow rate and water flow rate. Also, SMD is increased when water flow rate is bigger. SMD is decreased when Air flow rate is bigger.

  • PDF

DESIGN AND APPLICATION OF A SINGLE-BEAM GAMMA DENSITOMETER FOR VOID FRACTION MEASUREMENT IN A SMALL DIAMETER STAINLESS STEEL PIPE IN A CRITICAL FLOW CONDITION

  • Park, Hyun-Sik;Chung, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.349-358
    • /
    • 2007
  • A single-beam gamma densitometer is utilized to measure the average void fraction in a small diameter stainless steel pipe under critical flow conditions. A typical design of a single-beam gamma densitometer is composed of a sealed gammaray source, a collimator, a scintillation detector, and a data acquisition system that includes an amplifier and a single channel analyzer. It is operated in the count mode and can be calibrated with a test pipe and various types of phantoms made of polyethylene. A good average void fraction is obtained for a small diameter pipe with various flow regimes of the core, annular, stratified, and bubbly flows. Several factors influencing the performance of the gamma densitometer are examined, including the distance between the source and the detector, the measuring time, and the ambient temperature. The void fraction is measured during an adiabatic downward two-phase critical flow in a vertical pipe. The test pipe has an inner diameter of 10.9 mm and a thickness of 3.2 mm. The average void fraction was reasonably measured for a two-phase critical flow in the presence of nitrogen gas.

비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향 (Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance)

  • 이동우;정모범
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

선박용 AA5083-H321의 유속에 의한 침식손상 방지를 위한 최적 음극방식전위 규명 (Investigation of Optimum Cathodic Protection Potential to Prevent Erosion with a Flow Rate of AA5083-H321 for Marine Vessels)

  • 정상옥;박일초;김성종
    • Corrosion Science and Technology
    • /
    • 제19권6호
    • /
    • pp.288-295
    • /
    • 2020
  • This study investigated the erosion-corrosion characteristics of 5038-H321 aluminum alloy in a natural seawater solution through various electrochemical experiments and flow rate parameters. Cathodic polarization experiments were conducted at flow rates ranging from 4 to 12 knots. Considering the concentration polarization section representing a relatively low current density, the range of the potentiostatic experiment was determined to be -1.6 to -1.0 V. The potentiostatic experiment was conducted at various potentials for 180 minutes in seawater. After the experiment, the corrosion characteristics were evaluated by observing surface morphology and measuring surface roughness. As a result, as the applied potential was lower, the amount of calcareous deposits increased and the roughness tended to increase. On the other hand, it was confirmed that the roughness was larger in the static condition than the flow rate condition due to the influence of the flow velocity. Variations in the chemical composition with flow rate variations were analyzed by energy-dispersive spectroscopy (EDS). In conclusion, the cathodic potential of AA5083-H321 in seawater was determined to be -1.0 V.

산지하천의 전자파 표면유속 측정에 기반한 유량 및 유속 관측 오차 분석 (Error Analysis for Electromagnetic Surface Velocity and Discharge Measurement in Rapid Mountain Stream Flow)

  • 김동수;양성기;정우열
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.543-552
    • /
    • 2014
  • Fixed Electromagnetic Wave Surface Velocimetry (Fixed EWSV) has been started to be used to measure flood discharge in the mountain stream, since it has various advantages such that it works well to continuously measure stream discharge even in the night time as well as very strong weather. On the contrary, the Fixed EWSV only measures single point surface velocity, thus it does not consider varying feature of the transverse velocity profile in the given stream cross-section. In addition, a conventional value of 0.85 was generally used as the ratio for converting the measured surface velocity into the depth-averaged velocity. These aspects could bring in error for accurately measuring the stream discharge. The capacity of the EWSV for capturing rapid flow velocity was also not properly validated. This study aims at conducting error analysis of using the EWSV by: 1) measuring transverse velocity at multiple points along the cross-section to assess an error driven by the single point measurement; 2) figuring out ratio between surface velocity and the depth-averaged velocity based on the concurrent ADCP measurements; 3) validating the capacity of the EWSV for capturing rapid flow velocity. As results, the velocity measured near the center by the fixed EWSV overestimated about 15% of the cross-sectional mean velocity. The converting ratio from the surface velocity to the depth-averaged velocity was 0.8 rather than 0.85 of a conventional ratio. Finally, the EWSV revealed unstable velocity output when the flow velocity was higher than 2 m/s.

100,000 RPM급으로 회전하는 에어공구의 성능측정에 관한 연구 (Study on Measuring the Performance of an Air Tool Operating at 100,000 RPM Class)

  • 조수용;김은종
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.44-50
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM in an unloaded state with very low torque. A 551 kPa in gauge pressure is supply to the inlet of an air tool. An experimental apparatus is developed as a friction type dynamometer. Inlet total pressure, air flow rate, rotational speed and operating force are measured simultaneously. Torque, output power and specific output power are obtained with different rotational speeds. Those are compared with the experimental results which were obtained by a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000 RPM. In order to reduce the rotational speed, a reduction gear is applied between the air tool and the commercial dynamometer. Torque and power obtained by the commercial dynamometer show $55\%$ lower than those obtained by the developed friction type dynamometer, because the mass is added to the rotor of air tool for the braking system of the commercial dynamometer and power loss is generated by the reduction gear. From the compared results, the friction type dynamometer should be applied for measuring the performance of the air tool operating at low torque and high RPM.

100,000 RPM급으로 회전하는 에어공구에서의 저토오크 측정에 관한연구 (Study on measuring the low torque on an air tool operating at 100,000 RPM class)

  • 김은종;조수용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2018-2023
    • /
    • 2003
  • An experiment is conducted for measuring the performance of an air tool, which is operated at 100,000 RPM at the unloaded state with the low torque. An experimental apparatus is developed as the power absorption type dynamometer. Inlet static pressure, flow rate, RPM and force are measured simultaneously. Torque, output power and specific output power are obtained. Those experimental results are compared with the experimental results obtained on a commercial dynamometer. However, no commercial dynamometers are available for measuring the torque above 30,000RPM. In order to use the commercial dynamometer, a reduction gear is applied to the shaft of dynamometer. Torque and power obtained on the commercial dynamometer show 50% lower than those obtained on a power absorption type dynamometer, because the inertia force is added to the air tool rotor for the braking system. Moreover, the starting RPM on the commercial dynamometer is less than 40,000RPM. From the compared results, they show that the power absorption type dynamometer should be applied for measuring the performance of an air tool operating at low torque and high RPM.

  • PDF

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

건물의 높이.너비 측정하기 체험수학 활동을 통한 삼각함수 지도방안 (A Study on Teaching Methods of Trigonometric Functions through Experimental Mathematics measuring height and width of buildings)

  • 김기원;김미나
    • 한국수학교육학회지시리즈E:수학교육논문집
    • /
    • 제23권3호
    • /
    • pp.785-801
    • /
    • 2009
  • 본 연구에서는 제7차 수학과 교육과정 10-나 삼각함수 단원에서 구체적 조작물과 실험을 이용한 건물의 높이 너비를 측정하는 체험수학 활동을 통하여 학생들이 수학수업에 흥미를 갖고 수학의 필요성을 느낄 수 있는 방안을 제시하였다.

  • PDF

NetFlow 기반 IPv6 사용자 Flow traffic 모니터링 (NetFlow based IPv6 user's Flow traffic monitoring)

  • 김성수;송왕철;오용택;최덕재
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 추계 종합학술대회 논문집
    • /
    • pp.42-46
    • /
    • 2006
  • Gbps급의 대역폭을 지원하는 차세대 인터넷이 등장함에 따라 다양한 초고속 응용 서비스들이 개발되어 시험 운용되고 있다. 이런 초고속 응용 서비스를 이용하는 도중에 문제가 발생하면 그 원인을 파악하기 어렵다. 하지만 특정 사용자 flow traffic에 대한 정보(종단 간 라우팅 경로, 구간별 패킷과 데이터 전송률과 라우터 상태정보)를 실시간으로 확인 할 수 있다면 문제 원인을 파악, 개선하기가 수월해질 것이다. 현재 한 지점에서 flow traffic을 모니터링 하는 시스템은 개발되어 있으나 사용자 flow traffic의 종단 간 흐름을 모니터링 할 수 있는 시스템은 개발되어 있지 않다. 따라서 본 연구에서는 사용자 flow data의 종단 간 라우팅 경로와 각 구간별 패킷 전송률과 데이터 전송률을 수치로 제공함으로써 데이터 소실 구간을 실시간으로 파악 가능한 종단 간 Flow 모니터링 시스템을 제안하고 구현하였다. 또한 IPv6을 사용하는 사용자 flow traffic에 대해서도 flow traffic 모니터링이 가능 하도록 구현 하였다.

  • PDF