• Title/Summary/Keyword: Flow Measurements

Search Result 1,813, Processing Time 0.03 seconds

Macroscopic Visualization of Diesel Sprays with respect to Nozzle Hole Numbers and Injection Angles (분공수와 분사각의 영향에 따른 거시적 디젤 분무 가시화)

  • Yongjin Jung;Jinyoung Jang;Choongsik Bae
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2024
  • Macroscopic visualization of non-evaporating sprays was experimentally conducted to investigate spray tip penetration and spray angle under low-density conditions, corresponding to an early injection strategy. Furthermore, injectors with varying injection angles (146° and 70°) and numbers of holes (8 and 14) were employed to examine the impact of injector configuration. Compared to the baseline injector, 8H146, which has 8 holes and a 146° injection angle, the spray tip penetration of the 8H70 injector was found to be longer. This can be attributed to higher momentum due to a smooth flow field between the sac volume and the nozzle inlet, which is located closer to the injector tip centerline. The increase in velocity led to intense turbulence generation, resulting in a wider spray angle. Conversely, the spray tip penetration of the 14H70 injector was shorter than that of the 8H70 injector. The competition between increased velocity and decreased nozzle diameter influenced the spray tip penetration for the 14H70 injector; the increase in momentum, previously observed for the 8H70 injector, contributed to an increase in spray tip penetration, but a decrease in nozzle diameter could lead to a reduction in spray tip penetration. The spray angle for the 14H70 injector was similar to that of the 8H146 injector. Moreover, injection rate measurements revealed that the slope for a narrow injection angle (70°) was steeper than that for a wider injection angle during the injection event.

Schematic Maps of Ocean Currents in the Yellow Sea and the East China Sea for Science Textbooks Based on Scientific Knowledge from Oceanic Measurements (관측 기반 과학적 지식에 근거한 과학교과서 황해 및 동중국해 해류모식도)

  • PARK, KYUNG-AE;PARK, JI-EUN;CHOI, BYOUNG-JU;LEE, SANG-HO;SHIN, HONG-RYEOL;LEE, SANG-RYONG;BYUN, DO-SEONG;KANG, BOONSOON;LEE, EUNIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.4
    • /
    • pp.151-171
    • /
    • 2017
  • Most of oceanic current maps in the secondary school science and earth science textbooks have been made on the base of extensive in-situ measurements conducted by Japanese oceanographers during 1930s. According to up-to-date scientific knowledge on the currents in the Yellow Sea and the East China Sea (YES), such maps have significant errors and are likely to cause misconceptions to students, thus new schematic map of ocean currents is needed. The currents in the YES change seasonally due to relatively shallow water depths, complex terrain, winds, and tides. These factors make it difficult to construct a unified ocean current map of the YES. Sixteen major items, such as the flow of the Kuroshio Current into the East China Sea and its northward path, the origin of the Tsushima Warm Current and its path into the Korea Strait, the path of Taiwan Warm Current, the Jeju Warm Current, the runoff pattern of the Yangtze River flow, the routes of the northward Yellow Sea Warm Current, the Chinese Coastal Current, and the West Korea Coastal Current off the west coast of the Korean Peninsula, were selected to produce the schematic current map. Review of previous scientific researches, in-depth discussions through academic conferences, expert discussions, and consultations for three years since 2014 enabled us to produce the final ocean current maps for the YES after many revisions. Considering the complexity of the ocean currents, we made seven ocean current maps: two representative current patterns in summer and winter, seasonal current maps for upper layer and lower layer in summer and winter, and one representative surface current map. It is expected that the representative maps of the YES, connected to the current maps of the East Sea and the Northwest Pacific Ocean, would be widely utilized for diverse purposes in the secondary-school textbooks as well as high-level educational purposes and even for scientific scholarly experts.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

Spatial and Seasonal Water Quality Variations of Han River Tributries (한강 주요지천의 지역적 및 계절적 수질변화)

  • Lee, Young Joon;Park, Minji;Son, Juyeon;Park, Jinrak;Kim, Geeda;Hong, Changsu;Gu, Donghoi;Lee, Joonggeun;Noh, Changwan;Shin, Kyung-Yong;Yu, Soon-Ju
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.6
    • /
    • pp.418-430
    • /
    • 2017
  • The quality of surface water is a very important issue to use various demands like as drinking water, industrial, agricultural and recreational usages. There has been an increasing demand for monitoring water quality of many rivers by regular measurements of various water quality variables. However precise and effective monitoring is not enough, if the acquired dataset is not analyzed thoroughly. Therefore, the aim of this study was to estimate differences of seasonal and regional water quality using multivariate data analysis for each investing tributaries in Han River. Statistical analysis was applied to the data concerning 11 mainly parameters (flow, water temperature, pH, EC, DO, BOD, COD, SS, TN, TP and TOC) for the time period 2012~2016 from 12 sampling sites. The seasonal water quality variations showed that each of BOD, TN, TP and TOC average concentration in spring and winter was higher than that of summer and fall, respectively. In summer each flow rate and average concentration of SS was higher than any other seasons, respectively. The correlation analysis were explained that EC had a strong relationship with BOD (r=0.857), COD (r=0.854), TN (r=0.899) and TOC (r=0.910). According to principal component analysis, five principal components (Eigenvalue > 1) are controlled 98.0% of variations in water quality. The first component included TP, DO, pH. The second component included EC, TN. The third component included SS. The fourth component included flow. The last component included Temp. Cluster analysis classified that spring is similar to fall and winter with water quality parameters. AnyA, WangsA, JungrA and TancA were identified as affected by organic pollution. Cluster analysis derived seasonal differences with investigating sites and better explained the principal component analysis results.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

A Study on Quality Changes of Domestic Frying Oils by Thermal Oxidation (시판식용유의 가열시간에 따른 품질 변화에 관한 연구)

  • Chang, You-Kyung;Lee, Joung-Won;Kim, Teak-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.112-118
    • /
    • 1978
  • Four domestic frying oils (soybean, corn, rapeseed and rice bran oil) were studied on their changing properties according to thermal oxidation by means of chemical analysis of their compositions and measurements of various physical and chemical properties. The content of linoleic acid which is an essential unsaturated fatty acid and the total amount of unsaturated fatty acids were highest in soybean oil (53.2% and 80.3% respectively) among the unheated frying oils and the degree of its thermal degradation was lowest during the continuous heating period for 48 hours at $180^{\circ}C$. However in general, the contents of unsaturated fatty acids were sharply decreased by thermal oxidation whereas the saturated fatty acid contents ranging 10-17% were not changed considerably, which largely agreed with the results of iodine value measurements. The free acid and peroxide values were also lowest in soybean oil (0.09 and 5.6 respectively) among the unheated oils whereas an anomalously high free acid value was observed in rapeseed oil (54.8) which was packed in unleveled glass bottles. Such a high value is probably ascribed to the photo-catalyzed oxidation during storage. The viscosity measurements have shown similar values before heating, but after thermal oxidation for 32 hours the rapeseed and rice bran oils became too thick to measure viscosity by capillary flow method with heavy darkening in color.

  • PDF

The Agreements between FEV1 and PEFR in the Patients of Mild Bronchial Asthma (외래 진료가 가능한 경증 천식 환자에서 1초간 노력성 호기량(FEV1)과 최대 호기유속(PEFR)간의 연관성)

  • Chang, Won Chul;Kim, Byung Kook;Kim, Soon Jong;Yoo, Kwang Ha;Lee, Tae-Hun;Lee, Jung Yeon;Lee, Kye Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.638-643
    • /
    • 2005
  • Background : Several studies have shown considerable disagreement when using the $FEV_1$ and PEFR to assess the severity of an airflow obstruction. A differential classification of the severity of asthma would lead to serious differences in the evaluation and management of asthma. The aim of this study was to examine the relationship between the $FEV_1$ and PEFR in asthma patients with mild symptoms. Methods : In this study, the PEFR and $FEV_1$ were obtained from 92 adult asthma patients with mild symptoms attending an outpatient pulmonary clinic. The mean differences and the limits of agreement in the paired measurements of the $FEV_1$ and PEFR were calculated. Results : There was a considerable correlation between the $FEV_1$ and PEFR measurements when expressed as a % of the predicted values (r=0.686, p<0.01). The 95% limit of agreement (mean difference ${\pm}1.96SD$) between the $FEV_1$ % and PEFR % were acceptable(-27.4%~33.8%). In addition, the weighted ${\kappa}$(kappa) coefficient for the agreement between the $FEV_1$ % and PEFR % was 0.74 (95% CI, 0.63-0.81), indicating excellent agreement between the two measurements. Conclusion : The spirometer ($FEV_1$) and the Mini-Wright peak flow meter (PEFR) can be used interchangeably in adult asthma patients with mild symptom.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

Sapflux Measurement Database Using Granier's Heat Dissipation Method and Heat Pulse Method (수액류 측정 데이터베이스: 그래니어(Granier) 센서 열손실탐침법(Heat Dissipation Method)과 열파동법(Heat Pulse Method)을 이용한 수액류 측정)

  • Lee, Minsu;Park, Juhan;Cho, Sungsik;Moon, Minkyu;Ryu, Daun;Lee, Hoontaek;Lee, Hojin;Kim, Sookyung;Kim, Taekyung;Byeon, Siyeon;Jeon, Jihyun;Bhusal, Narayan;Kim, Hyun Seok
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.4
    • /
    • pp.327-339
    • /
    • 2020
  • Transpiration is the movement of water into the atmosphere through leaf stomata of plant, and it accounts for more than half of evapotranspiration from the land surface. The measurements of transpiration could be conducted in various ways including eddy covariance and water balance method etc. However, the transpiration measurements of individual trees are necessary to quantify and compare the water use of each species and individual component within stands. For the measurement of the transpiration by individual tree, the thermometric methods such as heat dissipation and heat pulse methods are widely used. However, it is difficult and labor consuming to maintain the transpiration measurements of individual trees in a wide range area and especially for long-term experiment. Therefore, the sharing of sapflow data through database should be useful to promote the studies on transpiration and water balance for large spatial scale. In this paper, we present sap flow database, which have Granier type sap flux data from 18 Korean pine (Pinus koraiensis) since 2011 and 16 (Quercus aliena) since 2013 in Mt.Taehwa Seoul National University forest and 18 needle fir (Abies holophylla), seven (Quercus serrata), three (Carpinus laxiflora and C. cordata each since 2013 in Gwangneung. In addition, the database includes the sapling transpiration of nine species (Prunus sargentii, Larix kaempferii, Quercus accutisima, Pinus densiflora, Fraxinus rhynchophylla, Chamecypans obtuse, P. koraiensis, Betulla platyphylla, A. holophylla, Pinus thunbergii), which were measured using heat pulse method since 2018. We believe this is the first database to share the sapflux data in Rep. of Korea, and we wish our database to be used by other researchers and contribute a variety of researches in this field.