• Title/Summary/Keyword: Flow Field 3D Measurement

Search Result 64, Processing Time 0.03 seconds

Development of the 80-kW Test Tractor for Load Measurement of Agricultural Operations (농작업 부하 계측을 위한 80kW급 계측 트랙터 개발 및 검증)

  • Cho, Seung-Je;Kim, Jeong-Gil;Park, Jin-Sun;Kim, Yeon-Soo;Lee, Dongkeun
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.46-53
    • /
    • 2022
  • RIn this study, a test tractor that could measure various types of agricultural operational loads was developed, and its performance was verified. This tractor could be used to measure the load generated during agricultural work and convert the related data into a database. A test tractor was developed using an 80-kW-rated load tractor, and it could measure various types of field test data, such as engine torque and rpm, wheel torque, PTO(power take-off) torque, hexometer, IMU/INS sensor, steering angle sensor, hydraulic pressure, and flow sensor data. To verify the developed test tractor, a verification test using an agriculture rotavator was performed. The test conditions were L1, L2, and L3 based on the tractor's main and sub-transmission stages, and stages 1 and 2 were selected as the PTO. In a comparison of the analyzed test data, similar tendencies in the test results of this research and other research (Kim's research) were seen. Through this, the developed test tractor was verified. In the future, we plan to conduct research on the tractor developed in this study using various attached working machines.

Mixed Convection between Inclined Parallel Plates with different Temperatures (온도차를 갖는 경사진 평행평판 내의 혼합대류 열전달)

  • Piao, R.L.;Kwon, O.B.;Bae, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.33-39
    • /
    • 2005
  • Experiments are performed to study the mixed convection flow and heat transfer in an inclined parallel plates with the upper part cooled and the lower part heated uniformly. The Reynolds number ranges from $4.0{\times}10^{-3}\;to\;6.2{\times}10^{-2}$, the angle of inclination, ${\theta}$, from 0 to 45 degree from the horizontal line, and Pr of the high viscosity fluid is 909. In this paper, the PIV(Particle image velocimetry) with TLC(Thermo-sensitive liquid crystal) tracers is used for visualizing and analysis. This method allows simultaneous measurement of velocity and temperature field at a given instant of time. Quantitative data of the temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. This paper describes the methods, and presents the quantitative visualization of mixed convection. From this study, it is found that the flow pattern can be classified into three patterns which are affected by Reynolds number and the angle of inclination.

  • PDF

Velocity and Pressure Measurement of Channel Cavity Flow by PTV (PTV에 의한 채널캐비티 유동의 속도 및 압력계측)

  • Cho, D.H.;Kim, J.G.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.59-66
    • /
    • 1997
  • The present study adopted the PTV method for the velocity acquisition. The system consists of an image grabber built-in a personal computer and a laser-based sheet light projector and particle identification softwares. Velocity vectors are obtained, by PTV and they are used as velocity components for Poisson equation for pressure. Related boundary conditions and no-slip condition at solid wall and the linear velocity extrapolation on the upper side of cavity are well examined for the present study. For calculation of pressure, resolution of grid is basically $40{\times}40$ and 2-dimensional uniform mesh using MAC staggered grid is adopted. The result of experiment reveal that, newly suggested measuring method is capable of estimating pressure and velocity distribution of flow field reasonably.

  • PDF

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Aerodynamic Heating Analysis of Spike-Nosed Missile (스파이크가 부착된 유도탄의 공력 가열 해석)

  • Jung Suk Young;Yoon Sung Joon;Byon Woosik;Ahn Chang Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.21-29
    • /
    • 2004
  • Numerical analysis of aerodynamic heating for KPSAM is performed using aerodynamic heating model suitable to KPSAM, which has complex flow field resulting from the spike attached to the dome, such as large separation area and the strong shock/boundary layer interaction region around reattachment point on the dome. The aerodynamic heating model is validated and modified through the comparison between the flight test measurement and the thermal analysis results. TFD temperature sensors are installed on the dome to measure surface temperature during the flight. Computation results, obtained from the heat transfer analysis on the sensors, agree well with flight test data. The aerodynamic heating model provides heat transfer rate into surface as a boundary condition of unsteady 1D/axisymmetric thermal analysis on the missile structure. The axisymmetric thermal analysis using FLUENT is more versatile than the 1D analysis and can be applied to the heating problem related with complex structures and multi-dimensional heat transfer problems such as prediction of temperature rise at contact surface of different materials.

Investigation on Water Quality Variation Characteristics during Dry Season in Namhan River Drainage Basin (남한강수계 저수기 수질변동 특성에 관한 연구)

  • Lee, H.J.;Kong, D.S.;Kim, S.H.;Shin, K.S.;Park, J.H.;Kim, B.I.;Kim, S.M.;Jang, S.H.;Cheon, S.U.
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.889-896
    • /
    • 2007
  • From the direct outflow of Chungju Dam to the junction of water body and watershed in Paldang lake is the scope of this research. This study performed to investigate the main cause of water quality deterioration and the influenced region in the middle field range of the Namhan river Basin with the onsite measurement of water quality and flow rate simultaneously during spring dry season. The purpose of this study is to find out the time-spatial variation characteristics of water quality and flow rate. Following the flow direction $BOD_5$ and $COD_{Mn}$ concentration increased to the highest value of 3.7 mg/L, 5.9 mg/L at Wolgesa respectively. Chl.a concentration increased to $50mg/m^3$ or so at Kangsang, after that it decreased to $37mg/m^3$ at the junction of Paldang lake. Organic matter concentration variation trend showed similar than that of Chl.a. Also $BOD_5$ concentration tendency was similar to Chl.a in every measuring sites except Paldang lake mixing zone. The major factors of water quality deterioration in Namhan river and Paldang lake during dry season were algal bloom and followed internal production. High phosphorus load from Dalcheon and Seom river caused dry season algal bloom and internal production in transitional zone which was stagnant area in downstream of Namhan river.

A Study on the Information Gathering Function of Research and Development Laboratories Established within Industrial Firms (산업체 부설연구소의 정보기능에 관한 연구)

  • Cho In Sook
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.16
    • /
    • pp.281-327
    • /
    • 1989
  • This dissertation is presented in two major parts. The first part presented in Chapter 3 attempts to verify the major hypothesis of the present study that the research and development laboratories(hereafter referred to R&D laboratories), establishd withine industrial firms to develop new technologies needed for their own industrial activities, may have another but very important functions to bring information on the externally generated technologies to attention of their respective management decision makers, eventually resulting in the transfer of technology; and such information functions of the R&D laboratories may be better performed by well-organised laboratories than by poorly-organised ones. The second part presented in Chapters 4, 5, 6 and 7 discusses, after the preceding hypotheses has been verified, some desirable situations of the R&D laboratories in facilitating the flow of information on new technologies developed in the world into their industrial firms, centering on the organisational positions and the major fields of interest of the person in charge of the R&D centers, services of the library and technological information office supporting the R&D laboratories, and frequencies of direct contacts of research and development workers with experts in the world and of participation in various conferences, seminars, workshops, exhibitions, etc. Now that there is no recognised instrument and method available for direct measurement of volume of technological information transfered into a particular industrial firm, the number of technologies introduced into a given firm is employed in the present study as an analogous parametre indicating volume of technological information transfered into the firm during a particular period of time. A logical attempt to justify the use of the indirect paramentre is made in Chapter two. vidences needed to verify the hypotheses of the present study are collected through the various publications of the Korea Industrial Research Institutes and other agencies and institutions related to industrial research activities, and through responses to the questionnaire posted to a sample of the 66 R&D laboratories on 6 May 1987 and returned by 30 August of the same year. Some findings and conclusions made in the study are summarised as follows: (1) More information on externally developed technologies flows into the industrial firm with a R&D laboratory of its own than into the industrial firm without one, and naturally, more chances of transfer of technologies are given to the former than to the latter (see 3. 2) (2) After establishing an R&D laboratory, more technological information flows into the industrial firm than before establishing one (see 3. 3) (3) More technological information flows into the industrial firm with a well-organised R&D laboraory than into the firm with a poorly-organised one (see 3. 4) (4) More technological information flows into the ndustrial firm where the director of its R&D laboratory has status qualified to participate in the highest managerial decision making processes of the firm than into the industrial firm where the director does not have such status (see 4. 2) (5) More technological information flows into the industrial firm where the director of R&D laboratory does not hold other positions within the firm than into the industrial firm where the director holds other positions (see 4.3) (6) There is evidence showing that quantities of technological information transfered into industriali firms vary with the case that the major background of the director of the R&D laboratory is the same as the main field of R&D activities of his or her laboratery, the case that the director's background is partly related to the field of R&D activities of the laboratory, and the case that the director's major background is different from the field of R&D activities of the laboratory (see 4.4) (7) More technological information flows into the industrial firm with the director of its R&D laboratory appointed from among professional research and development workers than into the industrial firm with the director of its R&D laboratory appointed from among general managers (see 4.5) (8) More technological information flows into the industrial firm with its R&D laboratory which has established a library service unit within its own jurisdiction than into the industrial firm with its R&D laboratory which has established a library service unit within its own jurisdiction than into the industrial firm with its R&D laboratory which uses a library within the firm but outside the laboratory (see 5. 1) (9) More echnological information flows into the industrial firm with a technological information office of its own than into the industrial firm without such an office (see 5. 2) (10) More technological information flows into the industrial firm with a large research and development staff in its R&D laboratory than into the industrial firm with a small staff in its R&D laboratory (see 5. 2) (11) More technological information flows into the industrial firm with its R&D laboratory whose staff members more frequently contact experts in the conferences, seminars, symposiums, and workshops held in foreign countries and novelties in the world's major exhibitions than into the industrial firm with its R&D laboratory whose staff members less frequently contact such experts and novelties (see 6. 2 ; 6. 3)

  • PDF

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.17 no.3
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.

The intrinsic instabilities of fluid flow occured in the melt of Czochralski crystal growth system

  • Yi, Kyung-Woo;Koichi Kakimoto;Minoru Eguchi;Taketoshi Hibiya
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.179-200
    • /
    • 1996
  • The intrinsic instabilities of fluid flow occurred in the melt of the Czochralski crystal growth system Czochralski method, asymmetric flow patterns and temperature profiles in the melt have been studied by many researchers. The idea that the non-symmetric structure of the growing equipment is responsible for the asymmetric profiles is usually accepted at the first time. However further researches revealed that some intrinsic instabilities not related to the non-symmetric equipment structure in the melt could also appear. Ristorcelli had pointed out that there are many possible causes of instabilities in the melt. The instabilities appears because of the coupling effects of fluid flow and temperature profiles in the melt. Among the instabilities, the B nard type instabilities with no or low crucible rotation rates are analyzed by the visualizing experiments using X-ray radiography and the 3-D numerical simulation in this study. The velocity profiles in the Silicon melt at different crucible rotation rates were measured using X-ray radiography method using tungsten tracers in the melt. The results showed that there exits two types of fluid flow mode. One is axisymmetric flow, the other is asymmetric flow. In the axisymmetric flow, the trajectory of the tracers show torus pattern. However, more exact measurement of the axisymmetrc case shows that this flow field has small non-axisymmetric components of the velocity. When fluid flow is asymmetric, the tracers show random motion from the fixed view point. On the other hand, when the observer rotates to the same velocity of the crucible, the trajectory of the tracer show a rotating motion, the center of the motion is not same the center of the melt. The temperature of a point in the melt were measured using thermocouples with different rotating rates. Measured temperatures oscillated. Such kind of oscillations are also measured by the other researchers. The behavior of temperature oscillations were quite different between at low rotations and at high rotations. Above experimental results means that the fluid flow and temperature profiles in the melt is not symmetric, and then the mode of the asymmetric is changed when rotation rates are changed. To compare with these experimental results, the fluid flow and temperature profiles at no rotation and 8 rpm of crucible rotation rates on the same size of crucible is calculated using a 3-dimensional numerical simulation. A finite different method is adopted for this simulation. 50×30×30 grids are used. The numerical simulation also showed that the velocity and flow profiles are changed when rotation rates change. Futhermore, the flow patterns and temperature profiles of both cases are not axisymmetric even though axisymmetric boundary conditions are used. Several cells appear at no rotation. The cells are formed by the unstable vertical temperature profiles (upper region is colder than lower part) beneath the free surface of the melt. When the temperature profile is combined with density difference (Rayleigh-B nard instability) or surface tension difference (Marangoni-B nard instability) on temperature, cell structures are naturally formed. Both sources of instabilities are coupled to the cell structures in the melt of the Czochralski process. With high rotation rates, the shape of the fluid field is changed to another type of asymmetric profile. Because of the velocity profile, isothermal lines on the plane vertical to the centerline change to elliptic. When the velocity profiles are plotted at the rotating view point, two vortices appear at the both sides of centerline. These vortices seem to be the main reason of the tracer behavior shown in the asymmetric velocity experiment. This profile is quite similar to the profiles created by the baroclinic instability on the rotating annulus. The temperature profiles obtained from the numerical calculations and Fourier transforms of it are quite similar to the results of the experiment. bove esults intend that at least two types of intrinsic instabilities can occur in the melt of Czochralski growing systems. Because the instabilities cause temperature fluctuations in the melt and near the crystal-melt interface, some defects may be generated by them. When the crucible size becomes large, the intensity of the instabilities should increase. Therefore, to produce large single crystals with good quality, the behavior of the intrinsic instabilities in the melt as well as the effects of the instabilities on the defects in the ingot should be studied. As one of the cause of the defects in the large diameter Silicon single crystal grown by the

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF