• 제목/요약/키워드: Flow Efficiency

검색결과 4,862건 처리시간 0.033초

고효율 룸 에어컨 설계를 위한 유동 분포 측정에 관한 연구 (Study on Measurement of Flow Distribution for Design of Room Air Conditioner with High-Efficiency)

  • 이수홍;라선욱;강근;고한서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.853-856
    • /
    • 2009
  • Test models which have geometrical similarities with a real room air conditioner (RAC) have been manufactured including visualization windows so that a laser beam can pass through a cross flow fan. Then, flow distributions of the RAC have been investigated using a visualization technique such as a Particle Image Velocimetry (PIV) to analyze an efficiency and noise of the RAC. Pitot tubes have also been used to measure the flow velocity inside the RAC with various positions to confirm the measurement accuracy of the PIV technique. The measured flow velocities have been analyzed and new designs of the RAC have been proposed to improve the efficiency and to reduce the noise for the RAC in this study.

  • PDF

Hydrodynamic Effect on the Inhibition for the Flow Accelerated Corrosion of an Elbow

  • Zeng, L.;Zhang, G.A.;Guo, X.P.
    • Corrosion Science and Technology
    • /
    • 제16권1호
    • /
    • pp.23-30
    • /
    • 2017
  • The inhibition effect of thioureido imidazoline inhibitor (TAI) for flow accelerated corrosion (FAC) at different locations for an X65 carbon steel elbow was studied by array electrode and computational fluid dynamics (CFD) simulations. The distribution of the inhibition efficiency measured by electrochemical impedance spectroscopy (EIS) is in good accordance with the distribution of the hydrodynamic parameters at the elbow. The inhibition efficiencies at the outer wall are higher than those at the inner wall meaning that the lower inhibition efficiency is associated with a higher flow velocity, shear stress, and turbulent kinetic energy at the inner wall of the elbow, as well as secondary flow at the elbow rather than the mass transport of inhibitor molecules. Compared to the static condition, the inhibition efficiency of TAI for FAC was relatively low. It is also due to a drastic turbulence flow and high wall shear stress during the FAC test, which prevents the adsorption of inhibitor and/or damages the adsorbed inhibitor film.

왕복유동에서 재생기 특성 및 열전달에 관한 수치해석 (A Numerical Study on the Regenerator Preformance and Heat Transfer in Oscillating Flow)

  • 이건태;강병하;이재헌
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.88-98
    • /
    • 1996
  • The present study is concerned with the flow friction and heat transfer characteristics of the combination of various regenerator materials, using the different Darcy number and porosity, which is filled uniformly and partially in a tube under oscillating flow condition. The poros medium is adopted as Brinkmann-Forschheimer extended Darcy model. Numerical results are obtained or the flow and temperature fields and described the effect of the combination of various regenerator materials and Womersley number on the pressure drop, the heat transfer and the regenerator efficiency. The results obtained indicate that not only heat transfer between the tube wall and oscillating flow but also the pressure drop at both ends of the regenerator are increased, while the regenerator efficiency is decreased in the increase of womersley number. It is also found that the friction factor is increased as Reynolds number is increased. The comparison between the combination of the various regenerator materials and the homogeneous regenerator material shows that the regenerator efficiency can be enhanced with the proper combination of various regenerator materials even though the averaged porosity of the regenerator is same.

  • PDF

열역학법에 의한 펌프의 수력효율측정 (Efficiency measuring in pump using Thermodynamic method)

  • 권영준;서창덕;정용채;박장원
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.546-551
    • /
    • 2004
  • An applying Thermodynamic method for the purpose of measuring hydraulic efficiency of pump-motor system, based on IEC60041 code, is not easy to adopt at field test. Even though there were splendid development in measuring technic in discharge measuring through the hydraulic machina lots of unsolved problems concerned in flow-rate are still remain in measuring hydraulic efficiency in hydraulic machine. The key point in measuring hydraulic efficiency is to measure exact flow-rate. So, Thermodynamic methode provides a good solution. This methode measures hydraulic efficiency by detecting the difference of temperature and pressure between the hydraulic process of machine, without measuring flow-rate of pump or turbine. By measuring temperature in mk level and absolute pressure in pascal, we can get a difference of thermodynamic specific energy in Moliere chart before and after of hydraulic process, md that difference is equal to hydraulic loses. Following the standard in proceeding Thermodynamic methode, I hope these trial and records make others be familiar to the thermal methode and make it easer to beginner for trial.

  • PDF

3차원 수치모의를 통한 침사지에서의 부유사 밀도류 해석 (Three-dimensional numerical modeling of sediment-induced density currents in a sedimentation basin)

  • 안상도;김기호;박원철
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.383-394
    • /
    • 2013
  • A sedimentation basin is used to remove suspended sediments which can cause abrasive and erosive wear on hydraulic turbines of hydropower plants. This sediment erosion not only decreases efficiency of the turbine but also increases maintenance costs. In this study, the three-dimensional numerical simulations were carried out on the overseas hydropower project. The simulations of flow and suspended sediment concentration were obtained using FLOW-3D computational fluid dynamics code. The simulations provide removal efficiency of a sedimentation basin based on particle sizes. The influence of baffles on the flow field and the removal efficiency of suspended sediments in the sedimentation basin has been investigated. This paper also provides the numerical simulations for sediment-induced density currents that may occur in the sedimentation basin. The simulation results indicate that the formation of density currents decreases the removal efficiency. When a baffle is installed in the sedimentation basin, the baffle provides intensive settling zones resulting in increasing the sediments settling. Thus the enhanced removal efficiency can be achieved by installing the baffle inside the sedimentation basin.

내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구 (Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures)

  • 김지훈;윤상우;권성호;성수환;배문오;김주한
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

Energy Efficiency Improvement of Vanadium Redox Flow Battery by Integrating Electrode and Bipolar Plate

  • Kim, Min-Young;Kang, Byeong-Su;Park, Sang-Jun;Lim, Jinsub;Hong, Youngsun;Han, Jong-Hun;Kim, Ho-Sung
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권3호
    • /
    • pp.330-338
    • /
    • 2021
  • An integral electrode-bipolar plate assembly, which is composed of electrode, conductive adhesive film (CAF) and bipolar plate, has been developed and evaluated for application with a vanadium redox flow battery (VRB) to decrease contact resistance between electrode and bipolar plate. The CAF, made of EVA (ethylene-vinyl-acetate) material with carbon black or CNT (Carbon Nano Tube), is applied between the electrode and the bipolar plate to enable an integral assembly by adhesion. In order to evaluate the integral assembly of VRB by adhesive film, the resistivity of integral assembly and the performance of single cell were investigated. Thus, it was verified that the integral assembly is applicable to redox flow battery. Through resistance and contact resistance of bare EVA and CAF films on bipolar plate were changed. Among the adhesive films, CAF film coated with carbon black showed the lowest value in through resistance, and CAF film coated with CNT showed the lowest value in contact resistance, respectively. The efficiency of VRB single cell was improved by applying CAF films coated with carbon black and CNT, resulting in the reduced overvoltage in charging process. Therefore, the energy efficiency of both CAF films, about 84%, were improved than that of blank cell, about 79.5 % under current density at 40 mA cm-2. The energy efficiency of the two cells were similar, but carbon black coated CAF improved the coulomb efficiency and CNT coated CAF improved the voltage efficiency, respectively.

Immersed Solid Method 를 이용한 외접형 기어 펌프의 수치해석 (Numerical Simulation of External Gear Pump Using Immersed Solid Method)

  • 윤용한;박병호;한용운;홍병주;심재술
    • 대한기계학회논문집B
    • /
    • 제38권1호
    • /
    • pp.95-101
    • /
    • 2014
  • 본 연구는 고속 회전형(~10,000 rpm) 기어펌프의 질량유량과 효율을 예측하기 위해서 2 차원 immersed solid method(ISM)를 이용한 수치해석을 수행하였다. 기어펌프와 하우징의 순환유동을 고려하기 위하여 유체 유동을 난류 유동으로 가정하였고, 기어 펌프의 입 출구의 일정 압력 조건하에 기어펌프의 회전 속도를 부가하였다. 기어펌프의 다양한 회전 속도 및 기어 끝 단과 하우징 사의의 서로 다른 간극에 대한 질량유량 및 효율을 검토하였다. 해석 결과로서, 회전 속도가 증가할수록 평균 질량유량 및 효율은 증가하였고, 기어펌프와 하우징의 간격이 증가할수록 평균 질량유량 및 효율은 감소하였다. 간격이 없는 조건하의 6,000 rpm, 8,000 rpm, 10,000 rpm 회전속도에의 효율은 각각 85.11 %, 90.94 %, 93.62 % 를 얻었고, 간격이 0 m, 0.00001 m, 0.00003 m 에 대해서 효율은 각각 93.62 %, 93.29 %, 92.74 % 를 얻었다.

$TiO_2$ 광촉매반응을 이용한 수중의 은이온 제거에 관한 연구 (A Study on the Removal of Ag(I) in Water Using $TiO_2$ Photocatalysis)

  • 김현용;조일형;양원호;김민호;이홍근
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.58-64
    • /
    • 2000
  • The photocatalytic removal of Ag(I) in water by $TiO_2$ at a various conditions, which are initial Ag(I) concentration, circulation flow rate, $TiO_2$ dosage and methanol concentration, was studied. A continuous flow system with a circular type reactor of the TiO2 suspensions with UV light through an photoreactor column was applied. The major results of this study were as follows; 1. First order kinetics was observed from the result at different initial concentration of Ag(I). As the initial Ag(I) concentration was incereased, the reaction rate was decreased. 2. The removal efficiency of Ag(I) increased with increasing the circulation flow rate and $TiO_2$ dosage. However, over $4{\ell}/min$ of circulation flow rate and $1.5g/{\ell}$ of $TiO_2$ dosage, increasing of the efficiency reached a plateau. 3. The addition of methanol as hole scavenger enhanced the removal efficiency of Ag(I) but the removal efficiency reached a plateau over some level of methanol. 4. It was found that $TiO_2$ photocatalysis was effective method to remove of Ag(I) from aqueous solution.

  • PDF

2차원 비정상 유동 해석 효율 향상을 위한 Wavelet 기법 응용 연구 (RESEARCH ON THE WAVELET METHOD FOR THE IMPROVEMENT OF COMPUTATIONAL EFFICIENCY OF TWO DIMENSIONAL FLOW PROBLEMS)

  • 강형민;홍상원;정지훈;김규홍;이도형;이동호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.42-49
    • /
    • 2008
  • A wavelet method is presented in order to improve the computational efficiency of two dimensional unsteady flow problems while maintaining the order of accuracy of conventional CFD schemes. First, by using the interpolating wavelet transformation including decomposition and thresholding, an adaptive dataset to a solution is constructed. Then, inviscid and viscous fluxes are calculated only at the points within an adaptive dataset, which enhances the computational efficiency. Second, thresholding step is modified to maintain the spatial and temporal accuracy of conventional CFD schemes automatically by selecting the threshold value between user-defined value and the magnitude of spatial or temporal truncation error. The wavelet method suggested in this study is successfully applied to various unsteady flow problems and it is shown that the computational efficiency is enhanced with maintaining the computational accuracy of CFD schemes.

  • PDF