• Title/Summary/Keyword: Flow Disturbance

Search Result 337, Processing Time 0.026 seconds

Clinical Outcome of Educational Program Using Self-monitoring of Peak Expiratory Flow Rate for Asthma Patients (천식 환자에 있어서 최대호기 유속의 자가 모니터링을 이용한 복약지도의 유용성)

  • Lee, Myung Bok;Shin, Hyun Taek;Kim, Sun Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.2
    • /
    • pp.97-102
    • /
    • 1999
  • The effects of pharmacist's intervention for asthma patients using self-monitoring of peak expiratory flow rate in medication teaching model was evaluated for 3 months in improving clinical outcomes including emergency visits, hospitalizations, antibiotics use, symptoms and sleep disturbance. Twenty seven patients were enrolled in study and twenty three patients completed the follow-up schedules. The selected patients were given the pre-designed instruction for medication including appropriate use of medication, metered-dose inhaler(MDI) technique, identifying and controling asthma triggers and recognizing early signs of deterioration. There were significant improvements in clinical outcomes, in terms of emergency visits, hopitalizations, antibiotics use, symptoms and sleep disturbance. There were also significant improvements in the MDI use, environmental control, and medication knowledges. There was a progressive increase in peak expiratory flow rate during the three-month intervention. In conclusion, pharmacist's intervention using self-monitoring of peak expiratory flow rate has a significant impact on improving clinical outcomes in asthma patients.

  • PDF

Flow Rate Control System Design for the Industrial Valve (산업용 밸브의 유량제어 시스템 설계)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.387-392
    • /
    • 2020
  • This paper proposes a flow-rate control system for industrial valves. Industrial valves are used in piping systems to control the flow rate and pressure. In general, valves used in pipelines are classified into globe valves, butterfly valves, and ball valves according to the shape. Motor, hydraulic, and pneumatic systems are used for operating valves. The flow meter should measure the flow rate when configuring the flow-rate control system. On the other hand, because the flow rate of the valve can be expressed by flow coefficient, a control scheme is proposed using the pressure deviation, which measures at the front and rear of the valve. The transfer function for the valve, according to the control input, was estimated using the signal compression method. Based on the induced transfer function, the disturbance observer was designed to improve the command following the performance of the valve stem. The performance of the proposed control method is compared with the flow-rate control result using the flow meter used.

Characteristics of Multipath Ultrasonic Flowmeter Installed Upstream and Downstream of Flow Disturbance Factors-Contraction, Expansion, and Tee Pipe (유동교란인자(축소·확대관, Tee관)상하류에 설치된 다회선초음파 유량계의 특성)

  • Lee, Dong-Keun;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.877-883
    • /
    • 2012
  • Multipath ultrasonic flowmeters are increasingly being used for the purpose of accurate flow measurement. However, an installation standard has not yet been established for these flowmeters, and this can cause considerable confusion during field installation. There is a need for a minimum straight run to ensure the measurement accuracy of a flowmeter installed upstream and downstream of flow disturbance factors-expansion, contraction, and tee pipes. Experiments were performed by using multipath flowmeters that have less than ${\pm}0.5%$ accuracy-4-paths 1-unit and 2-paths 1-unit are of foreign make, whereas 5-paths 2-units are of domestic make-to determine the straight run under the above conditions. We carried out experiments repeatedly by considering a straight run, velocity, and suggested installation standards for a multipath ultrasonic flowmeter that satisfies the tolerance limits.

A study on the application of the intelligent control algorithms to the flow control system (유량제어계통에 대한 지능형 제어 알고리즘 적용연구)

  • 김동화;조일인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1792-1795
    • /
    • 1997
  • It is difficulte to control in the flow system because there are many disturbance. So it is impossible to control delicately sometimes by PI or PID. In this paper, we study on the application of intellignet control algorithms such as 2DOF PID control, neural network, Fuzzy contro, Relay feedback to the flow control system. the resultings are 2DOF-PID control is more good response.

  • PDF

The most unstable case in plane Poiseuille flow on transition by using pseudospectra method (Pseudospectra를 이용한 평행 평판 사이 유동에서 가장 불안정한 경우)

  • Choi Sangkyu;Chung Myung Kyoon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.691-694
    • /
    • 2002
  • The most unstable situation of laminar plane Poiseuille flow for transition to turbulence is investigated by using a pseudo-spectral method. A number of various disturbance modes are tested and it is found that the flow is the most unstable when it is disturbed by an oblique wave with an angle of $29.7^{\circ}$.

  • PDF

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header (주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

Vibration Effect for Branch Pipe System due to Main Steam Header Pulsation (주증기 배관 헤더의 맥동이 분기 배관에 미치는 영향)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.780-785
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of a nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve or heather generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 7nn nuclear power plant. The exciting sources and response or the piping system are investigated by using on site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3Hz, 4.4Hz and 6.6Hz transferred from main steam header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness were installed to reduce excessive vibration.

  • PDF

Analysis of River Disturbance using a GIS(II) (GIS기법을 이용한 하천 교란 실태의 분석(II))

  • Park, Eun-Ji;Kim, Kye-Hyun;Jang, Chang-Lae
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.4
    • /
    • pp.27-35
    • /
    • 2008
  • Current re-arrangement of rivers and waterways have been made uniformly ignoring characteristics of individual rivers thereby aggravating artificial river restructuring. On the contrary, quantitative techniques to evaluate the aftermath of artificial river disturbance such as uprising of river bed, intrusion of foreign fisheries, and changes of ecological habitats are not available. To establish such quantitative techniques, analysis of the river changes to evaluate the major causes of the river disturbance and its impacts is essential. Therefore, research for proposing a method which can be applied for the development of techniques to investigate river disturbance according to the major factors for the domestic rivers using airphotos and GIS techniques was preceded. In this study, the study area on the downstream of the river was selected and analysis of river disturbance using preceding method was done to confirm the benefit of analyzing river disturbance using GIS techniques. Trend analysis of the waterway sinuosity and changes of the flow path leaded to detailed verification of the river disturbance for specific location or time period, and this enabled to generate relatively accurate numbers representing sinuosity of the waterway and relevant changes. Also, it is possible to predict the effect on the current re-arrangement of the river and waterway to river flow using the analysis of past river change. It is necessary to establish GIS based proper measures for environmental river restoration using the results from this study and future works.

  • PDF

Stability Analysis of the Karman Boundary-Layer Flow

  • Lee, Yun-Yong;Hwang, Young-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.1
    • /
    • pp.50-63
    • /
    • 2002
  • The Karman boundary-layer has been numerically investigated for the disturbance wave number, wave velocity, azimuth angle and radius (Reynolds number, Re). The disturbed flow over rotating disk can lead to transition at a much lower Re than that of the well-known Type I instability. This early transition is due to the excitation of the Type II. Presented are the neutral stability results concerning these instabilities by solving newly formulated stability equations with consideration of whole convective terms. When the present numerical results are compared with the previously known results, the value of critical Re corresponding to Type I is moved from ${Re}_{c.1}$=285.3 to 270.2 and the value corresponding to Type II from ${Re}_{c.2}$=69.4 to 36.9, respectively. Also, the corresponding wave number is moved fro)m $k_1$=0.378 to 0.386 for Type I; from $k_2$=0.279 to 0.385 for Type II. For Type II, the upped limit of wave number and azimuth angle is $k_u$=0.5872, $\varepsilon_u$=$-17.5^{\circ}$, while its lower limit is near $k_u$=0, $\varepsilon_u$=$-28.4^{\circ}$. This implies that the disturbances will be relatively fast amplified at small Re and within narrow bands of wave number compared with the previous results.

Stability of the K rm n Boundary Layer Flow (Karman 경계층 유동의 안정성에 관한 연구)

  • 황영규;이윤용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.771-781
    • /
    • 2000
  • The Karman boundary-layer, has been numerically investigated for the disturbance wave number, wave velocity, azimuth angle and radius (Reynolds number, Re). The disturbed flow over rotating disk can lead to transition at a much lower Re than that of the well-known Type 1 mode of instability. This early transition is due to the excitation of the Type II mode. Presented are the neutral stability results concerning these modes by solving new formulated vorticity equations with consideration of whole convective terms. When the present numerical results are compared with the previously known results, the value of critical Re corresponding to Type I is moved from Rec,! =285.3 to 270.2 and the value corresponding to Type II is from $Re_{c,2}$=69.4 to 36.9, respectively. Also, the corresponding wave number is moved from $k_1$ =0.378 to $k_1$ =0.389 for Type I; from $k_2$ =0.279 to $k_2$=0.385 for Type II. For Type II, the upper limit of wave number and azimuth angle is $k_U$=0.5872,$varepsilon_U=-18^{\circ}$ , while its lower limit is$k_L$ =0.05, $varepsilon_L=-27^{\circ}$ This implies that the disturbances will be relatively fast amplified at small Re and within narrow bands of wave number compared with the previous results.

  • PDF