• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.028 seconds

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화)

  • Kwon O-Sang;Kim Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

HPLC Chromatographic Methods for Simultaneous Determination of Pholcodine and Ephedrine HCI with Other Active Ingredients in Antitussive-Antihistamine Oral Liquid Formulations

  • Abdallah, Rokia M.
    • Natural Product Sciences
    • /
    • v.12 no.1
    • /
    • pp.55-61
    • /
    • 2006
  • A description of simple, isocratic and precise reversed phase HPLC methods is given for simultaneous quantification of pholcodine and ephedrine hydrochloride together with either carbinoxamine maleate or terfenadine in antitussive-antihistaminic oral pharmaceutical formulations. Separations were carried out on X-Terra and symmetry shield C18 column $(250\;{\times}\;4.6\;mm,\;5\;{\mu}m)$. The used isocratic elution systems were either $0.02\;M\;KH_2PO_4-acetonitrile$ in the ratio of 75 : 25 and pH adjusted to 7.70 with orthophosphoric acid or sodium hydroxide, for syrup (method A), or 0.02 octanesulphonic acid sodium salt solution-acetonitrile-acetic acid in the ratio of 75 : 25 : 0.5 for suspension (method B). The elution of both mixtures was achieved with a flow rate of 1 ml/min. Detection was carried out by UV absorbance at wavelengths of 220 and 250 nm for syrup and suspension, respectively. The quantification of the components in synthetic mixtures and actual syrup and suspension were calculated using the internal standard technique with metoclopramide HCl and codeine phosphate as internal standards (IS), respectively. The methods, for both mixtures, were validated and met all the requirements for the quality control analysis recommended by FDA and ICH.

Quantitative Analyses for the Quality Evaluation of Salviae Miltiorrhizae Radix by HPLC

  • Fang, Zhe;Moon, Dong-Cheul;Son, Kun-Ho;Son, Jong-Keun;Min, Byung-Sun;Woo, Mi-Hee
    • Natural Product Sciences
    • /
    • v.16 no.4
    • /
    • pp.251-258
    • /
    • 2010
  • In this study, quantitative analysis for the quality evaluation of Salviae Miltiorrhizae Radix using HPLC/UV was developed. For quantitative analysis, six major bioactive compounds were determined. The separation conditions employed for HPLC/UV were optimized using ODS $C_{18}$ column ($250{\times}4.6\;mm$, $5\;{\mu}m$) with gradient condition of A (1% formic acid in $H_2O$) and B (acetonitrile : methanol : formic acid = 100 : 75 : 1) as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 280 nm. These methods were fully validated with respect to the linearity, accuracy, precision and recovery. The HPLC/UV method was applied successfully to the quantification of six major compounds in the Salviae Miltiorrhizae Radix. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis.

Detection of Phagocytosis-Promoting Factor of Culture Supernatant from Feline Peripheral Blood Mononuclear Cells Cultured with Egg White Derivatives (계난백유래물질로 배양한 고양이 말초혈액 단핵구세포 배양상층액중의 탐식촉진인자 검출)

  • 양만표;김기홍
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.31-36
    • /
    • 1999
  • The aim of this study is to determine the phagocytosis-promoting factor(s) for feline peripheral blood polymorphonuclear cells (PMN) by culture supernatant from mono-nuclear cells (MNC) treated with egg white derivatives (EWD). The phagocytic activity of PMN was analyzed by a flow cytometry system. The EWD did not show direct effect on the phagocytic response of PMN. The phagocytic activity of PMN was enhanced by culture supernatant from MNC but not PMN treated with EWD. Therefore, it was suggested that the enhanced phagocytic activity of feline PMN could be mediated by humoral factor(s) released from MNC treated with EWD. Thus, the phagocytosis-promoting factor(s) in supernatant fraction from MNC culture treated with EWD were isolated by reverse phase high pressure liquid chromatography. The resulting supernatant fraction on 29.02 minutes of retention time showed high phagocytic activity of PMN. The molecular weight of this supernatant fraction was 16 to 18 kDa when analyzed by capillary electrophoresis. The isoelectric point was pH 5.76 when assessed by ion-exchange chromatography. These results suggest that EWD stimulates feline MNC to elaborate a phagocytosis-promoting factor, 16 to 18 kDa of molecular weight, which could be an important mediator for the enhancement of phagocytic activity of feline peripheral blood phagocytes. Further study will be needed to elucidate this phagocytic factor.

  • PDF

Acoustical Anisotropy Evaluation of Pure Titanium plate Using Neural Network (신경회로망을 이용한 순 티타늄판재의 음향이방성 평가)

  • Park, Hee-Dong;Yun, In-Sik;Yi, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1103-1109
    • /
    • 2011
  • This research quantitatively confirmed an acoustical anisotropy that exists in a pure titanium plate from the signal of ultrasonic flow detection and suggested a new way to evaluate the acoustical anisotropy by inputting acquired characteristic of ultrasound signal into the neutral network. Using the fact with the suggested method that the characteristic of ultrasound signal is shown differently depending on the pure titanium plate's rolling direction, the neural network was constructed by extracting the characteristic that can decide each direction of $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ with waveform analysis program. As a result of inputting the characteristic of ultrasound signal acquired from a random rolling direction into the neural network that was built like this, it showed a pattern recognition rate higher than 95% on directions of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$.

A Study on the Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.204-209
    • /
    • 2005
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

A Novel Online Multi-section Weighed Fault Matching and Detecting Algorithm Based on Wide-area Information

  • Tong, Xiaoyang;Lian, Wenchao;Wang, Hongbin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2118-2126
    • /
    • 2017
  • The large-scale power system blackouts have indicated that conventional protection relays that based on local signals cannot fit for modern power grids with complicated setting or heavily loaded-flow transfer. In order to accurately detect various faulted lines and improve the fault-tolerance of wide-area protection, a novel multi-section weighed fault matching and detecting algorithm is proposed. The real protection vector (RPV) and expected section protection vectors (ESPVs) for five fault sections are constructed respectively. The function of multi-section weighed fault matching is established to calculate the section fault matching degrees between RPV and five ESPVs. Then the fault degree of protected line based on five section fault degrees can be obtained. Two fault detecting criterions are given to support the higher accuracy rate of detecting fault. With the enumerating method, the simulation tests illustrate the correctness and fault-tolerance of proposed algorithm. It can reach the target of 100% accuracy rate under 5 bits error of wide-area protections. The influence factors of fault-tolerance are analyzed, which include the choosing of wide-area protections, as well as the topological structures of power grid and fault threshold.

Simultaneous Determination of Albiflorin, Cinnamaldehyde, Cinnamic Acid, Daidzin, Glycyrrhizin, Liquiritin, Paeoniflorin and Puerarin in Galgeun-tang by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.31 no.6
    • /
    • pp.8-15
    • /
    • 2010
  • Objectives: We investigated to develop and validate HPLC-PDA methods for simultaneous determination of eight constituents in Galgeun-tang (GGT). Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230 nm, 254 nm, and 280 nm, were used for quantification of the eight marker components of GGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results: Calibration curves were acquired with $r^2$ > 0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each component was in the range of 87.33-101.38%, with an RSD less than 7.0%. The contents of the eight components in GGT were 1.98-12.17 mg/g. Conclusions: The established method will be applied for the quantification of marker components in GGT.

Effects of Snowfall Intensity on Freeway Travel Speed (Focused on Seohaean Freeway) (강설에 따른 고속도로 주행속도 변화연구 - 서해안고속도로를 중심으로 -)

  • Hong, Sung-Min;Oh, Cheol;Yang, Chung-Hoen;Jeon, Woo-Hoon
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.93-101
    • /
    • 2012
  • PURPOSES : Adverse weather conditions such as heavy rain, heavy snowfall, and thick fog and so on have highly affect on the change in traffic conditions on the road. In particular, heavy snowfall causes capacity reduction as well as crash occurrence. This study investigated the effects of snowfall on speed on a freeway. METHODS : Vehicle detection systems data were matched with corresponding weather station data by regression analysis. RESULTS : The results show that the travel speed is reduced by 6.7% under little snowfall and by 12.8% under heavy snowfall. Regarding the speed variation, 8.7% and 114.7% increases are observed under little snowfall and heavy snowfall, respectively. It is also found that 1 cm increase in snowfall leads to 0.4% decrease in travel speed. In addition, the travel speed increases by 0.4% when the temperature increases by $1^{\circ}C$. CONCLUSIONS : It is expected that the outcome of this study will be useful in establishing more effective strategies for winter operations and road maintenance in practice.

A Study on Wear-type Defects of Part and Materials in Wind Power Generation (풍력발전기 부품소재의 마모결함 검출에 관한 연구)

  • Kim, Sung-Hyun;Choi, Seung-Hyun;Jung, Na-Ra;Yoon, Cheon-Han;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.989-995
    • /
    • 2013
  • Unlike fossil-or nuclear fuel-based power generation, wind power generation using inexhaustible wind energy is a pollution-free, hazardless power generation method. In this study, ultrasound thermography is used for fabricating specimens of wind power generator bearings and wind power generator supplement flanges, and an optimally designed ultrasound horn and ultrasound excitation system are used for detecting damage to part materials of a wind power generation setup. In addition, thermal flow analysis and ultrasonic thermography imaging are comparatively analyzed for improving the detection reliability in terms of surface and internal defects of part materials and for verifying the developed system's field applicability and reliability.