• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.024 seconds

Implementation of a Data Processing Method to Enhance the Quality and Support the What-If Analysis for Traffic History Data (교통이력 데이터의 품질 개선과 What-If 분석을 위한 자료처리 기법의 구현)

  • Lee, Min-Soo;Cheong, Su-Jeong;Choi, Ok-Ju;Meang, Bo-Yeon
    • The KIPS Transactions:PartD
    • /
    • v.17D no.2
    • /
    • pp.87-102
    • /
    • 2010
  • A vast amount of traffic data is produced every day from detection devices but this data includes a considerable amount of errors and missing values. Moreover, this information is periodically deleted before it could be used as important analysis information. Therefore, this paper discusses the implementation of an integrated traffic history database system that continuously stores the traffic data as a multidimensional model and increases the validity and completeness of the data via a flow of processing steps, and provides a what-if analysis function. The implemented system provides various techniques to correct errors and missing data patterns, and a what-if analysis function that enables the analysis of results under various conditions by allowing the flexible definition of various process related environment variables and combinations of the processing flows. Such what-if analysis functions dramatically increase the usability of traffic data but are not provided by other traffic data systems. Experimantal results for cleaning the traffic history data showed that it provides superior performance in terms of validity and completeness.

Quantification of Entacapone in Human Plasma by HPLC Coupled to ESI-MS/MS Detection: Application to Bioequavalence Study (체외에서 ESI-MS/MS 탐지에 연결된 HPLC에 의한 Entacapon의 수량화: 생물학적 동등성 연구에 적용)

  • Balasekhara Reddy., Ch.;Baburao., Ch.;Chandrasekhar., K.B.;Kanchanamala., K.;RihanaParveen., S.K.;Ravikumar., Konda
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.523-532
    • /
    • 2010
  • The proposed method is simple, sensitive and specific Liquid chromatography-tandem mass spectrometry (LCESI-MS/MS) method for the quantification of Entacapone (EA) in human plasma using Entacapone-d10 (EAD10) as an internal standard (IS). Chromatographic separation was performed on Zorbax SB-C18, $2.1{\times}50\;mm$, $5\;{\mu}m$ column, mobile phase composed of 10 mM Ammonium formate (pH 3.0): Acetonitrile (60:40 v/v), with a flow-rate of 0.7 mL/min, followed by Liquid-liquid extraction. EA and EAD10 were detected with proton adducts at m/z $306.1{\rightarrow}233.1$ and $316.3{\rightarrow}233.0$ in multiple reaction monitoring (MRM) positive mode respectively. The method was validated over a linear concentration range of 1.00 - 2000.00 ng/mL with correlation coefficient ($r^2$) $\geq$ 0.9993. Intra and inter-day Precision within 3.60 to 7.30 and 4.20 to 5.50% and Accuracy within 97.30 to 104.20 and 98.30 to 105.80% proved for EA. This method is successfully applied in the bioequivalence study of healthy Indian human volunteers.

Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations (질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거)

  • Kim Tae-Uk;Yeon Kyeong-Ho;Cho Jaeweon;Moon Seung-Hyeon
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.297-309
    • /
    • 2005
  • As a number of potential endocrine disrupting compounds (EDCs) are released into the environment, recently growing attention has been drawn to them. Therefore sensitive and reliable analytical methods are essential to monitor those compounds. In this study, complementary CC-MS and LC-MS were employed to analyze the endocrine disrupters, and the results of two methods were compared for di(2-ethylhexyl)phthalate (DEHP), benzylbutylphthalate (BBP), pentachlorophenol (PCP), and 4,4'-Isopropylidenediphenol (Bisphenol-A, or BPA). The results indicate that it was possible to lower the detection limits of EDCs by LC-MS. Also, LC-MS enabled to identify the EDCs as almost intact molecules. Furthermore, this study presented a nanofiltration membrane (MWCO 250) and a ultrafiltration membrane (MWCO 1,000) filtration system as methods far removing EDCs from drinking water containing $\gamma$-BHC, p,p'-DDE, BBP, p,p'-DDT, DEHP, PCP, and BPA. Cross-flow type nanofiltrations showed $100\%$ removal of EDCs, and the result implies that MWCO 250 nanofilter was sufficient for treatment of EDCs. The ratio of permeate flux to mass transfer coefficient of nanofiltration, high flux ultrafiltration, and low flux ultrafiltration with ultrapure water were 0.67, 3.4, and 0.44, respectively. It was found that nanofiltration and low flux ultrafiltration were operated at a diffusion dominant condition, and the high flux ultrafiltration was operated at a convection dominant condition. Furthermore, a diffusion dominant process attained reasonable rejection of EDCs. The removal in the ultrafiltration was depending on the molecular weight of an EDC, and the filtration was governed by diffusion-dominant hydrodynamic conditions.

Validation of Method Determining Marmesin in Broussonetia kazinoki Extract (닥나무 추출물의 Marmesin 성분 분석법 검증)

  • Kwon, Jin Gwan;Seo, Changon;Hong, Seong Su;Seo, Dong-Wan;Oh, Joa Sub;Kim, Jin Kyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1604-1609
    • /
    • 2016
  • An HPLC analysis method was developed for standard determination of marmesin as a functional health material in Broussonetia kazinoki extract. HPLC was performed on a $C_{18}$ Kromasil column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 330 nm. The HPLC method was validated in accordance with International Conference on Harmonization guidelines for analytical procedures with respect to specificity, precision, accuracy, and linearity. The limit of detection and quantitation were 6.2 and $18.6{\mu}g/mL$, respectively. Calibration curves showed good linearity ($r^2$>0.9999), and the precision of analysis was satisfactory (less than 0.3%). Recoveries of quantified compound ranged from 100.35 to 101.18%. This result indicates that the established HPLC method is very useful for the determination of marker compounds in B. kazinoki extracts.

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

A Performance Monitoring System for Heterogeneous SOAP Nodes (이기종 SOAP 노드의 실시간 성능 모니터링 시스템)

  • Lee Woo-Joong;Kim Jungsun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.10 no.6
    • /
    • pp.484-498
    • /
    • 2004
  • In this paper. we propose a novel performance monitoring scheme for heterogeneous SOAP nodes. The scheme is basically based on two-level (kernel-level and user-level) packet filtering of TCP flows. By TCP flow, we mean a sequence of raw packet streams on a TCP transaction. In this scheme, we detect and extract SOAP operations embedded in SOAP messages from TCP flows. Therefore, it becomes possible to monitor heterogeneous SOAP nodes deployed on diverse SOAP-based middlewares such as .Net and Apache AXIS. We present two implementation mechanisms for the proposed scheme. The first mechanism tries to identify SOAP operations by analyzing all fragmented SOAP messages on TCP flows. However, a naive policy would incur untolerable overhead since it needs to copy all packets from kernel to user space. The second mechanism overcomes this problem by selectively copying packets from kernel to user space. For selective copying, we use a kernel-level packet filtering method that makes use of some representative TCP flags.(e.g. SIN, FIN and PSH). In this mechanism, we can detect SOAP operations only from the last fragment of SOAP messages in most cases. Finally, we implement a SOAP monitoring system using a component ca]led SOAP Sniffer that realizes our proposed scheme, and show experimental results. We strongly believe that our system will play a vital role as a tool for various services such as transaction monitoring and load balancing among heterogeneous SOAP nodes.

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.

A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System (태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구)

  • Kang, Kab-Seok;Tae, Dong-Hyun;Lee, Hu-Dong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.22-33
    • /
    • 2021
  • In the case of open phase faults caused by the disconnection of distribution feeders interconnected to a PV system, many problems can occur depending on the core type and wiring method of the grid-connected transformers. Moreover, open phase faults are difficult to detect because the open phase voltage of the existing protection relay (Open Phase Relay (47)) can be maintained, even though a disconnection fault occurred, depending on the wiring method and the iron core type of the grid-connected transformer for a PV system. Therefore, this paper proposes a novel algorithm to detect open phase faults by comparing the currents and phases between the primary and secondary sides of a grid-connected transformer. In addition, this paper presents the modeling of a distribution system and protection devices for detecting open phase faults using PSCAD/EMTDC S/W, and implements a test protection device for detecting open phase faults based on the above-mentioned modeling. The simulation and test results confirmed that the proposed algorithm is useful for detecting open phase faults according to the wiring method and iron core type of grid-connected transformer for a PV system because operation slope and unbalance rate of the primary current exceed the setting value (30[%]) of the protection device.

A Study on Detection and Monitoring in land creeping area by Using the UAV (무인기를 활용한 산지 땅밀림 피해지점 탐지 및 모니터링 방안 연구)

  • Seo, Jun-Pyo;Woo, Choong-Shik;Lee, Chang-Woo;Kim, Dong-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.481-487
    • /
    • 2018
  • This paper proposes a method to detect and monitor the land creeping area using a UAV to analyze the damaged area efficiently. Using a UAV, it was possible to secure the safety of the investigators before the field survey and effectively utilize it to establish an investigation plan because an orthophoto can be used to detect and scale the cracks in a land creeping area. In addition, it was possible to analyze the scale of the crack quantitatively by extracting the topographic information from the orthophoto. The study sites were found to have a total crack area of 1.01 ha, a length of 1.07 km, an average width of 10 m, and a step distance of 1 to 10 m. Periodic UAV measurements can be used to detect displacements on the land creeping area and monitor the direction and scale of crack spread. Therefore, it is expected to be used effectively during recovery planning. Applying the UAV to the land creeping area resulted in the qualitative and quantitative results quickly and easily in dangerous mountainous watersheds. Therefore, it is expected that it will contribute to the development of related industries because of the high availability of a UAV in forest soil sediment disasters, such as landslides, debris flow, and land creeping area.