• Title/Summary/Keyword: Flow Detection

Search Result 1,241, Processing Time 0.035 seconds

Rapid and Unequivocal Identification Method for Event-specific Detection of Transgene Zygosity in Genetically Modified Chili Pepper

  • Kang, Seung-Won;Lee, Chul-Hee;Seo, Sang-Gyu;Han, Bal-Kum;Choi, Hyung-Seok;Kim, Sun-Hyung;Harn, Chee-Hark;Lee, Gung-Pyo
    • Horticultural Science & Technology
    • /
    • v.29 no.2
    • /
    • pp.123-129
    • /
    • 2011
  • To identify unintended vertical gene-transfer rates from the developed transgenic plants, rapid and unequivocal techniques are needed to identify event-specific markers based on flanking sequences around the transgene and to distinguish zygosity such as homo- and hetero-zygosity. To facilitate evaluation of zygosity, a polymerase chain reaction technique was used to analyze a transgenic pepper line B20 (homozygote), P915 wild type (null zygote), and their F1 hybrids, which were used as transgene contaminated plants. First, we sequenced the 3'-flanking region of the T-DNA (1,277 bp) in the transgenic pepper event B20. Based on sequence information for the 3'- and 5'-flanking region of T-DNA provided in a previous study, a primer pair was designed to amplify full length T-DNA in B20. We successfully amplified the full length T-DNA containing 986 bp from the flanking regions of B20. In addition, a 1,040 bp PCR product, which was where the T-DNA was inserted, was amplified from P915. Finally, both full length T-DNA and the 1,040 bp fragment were simultaneously amplified in the F1 hybrids; P915 ${\times}$ B20, Pungchon ${\times}$ B20, Gumtap ${\times}$ B20. In the present study, we were able to identify zygosity among homozygous transgenic event B20, its wild type P915, and hemizygous F1 hybrids. Therefore, this novel zygosity identification technique, which is based on PCR, can be effectively used to examine gene flow for transgenic pepper event B20.

A Study on the Implementation and Performance Analysis of 900 MHz RFID System with Convolution Coding (콘벌루션 부호를 적용한 900MHz 대역 RFID 시스템 구현 및 성능 분석에 관한 연구)

  • Yun Sung-Ki;Kang Byeong-Gwon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In recent years, RFID has received much attention because of spread usage in industrial applications including factory, material flow, logistics and defense areas. However, there is only CRC-16 for error detection in ISO/IEC 18000-6 Protocols prepared for 860-960 MHz RFID, high error rates are expected in cases of high level of security and noisy envirionment. In this paper, we propose a usage of convolution code as a method for satisfying the high level of security requirement and system error performance.'1'he signal control function is implemented in a microprocessor with RF modulation and the convolutional encoding and Viterbi decoding are implemented in an FPGA chip.'The frame error rates are measured with and without convolution coding under the channel conditions of line-of- sight and non line-of-sight, respectively.

  • PDF

A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities (효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구)

  • Son, Gae-Seong;Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

Quantitative Analysis of the Eleven Marker Components in Traditional Korean Formula, Jakyakgamcho-Tang Decoction Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (UPLC-MS/MS를 이용한 작약감초탕 물 추출물 중 11종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.60 no.2
    • /
    • pp.64-72
    • /
    • 2016
  • Jakyakgamcho-tang is a well-known traditional herbal medicine and has been used for the treatment of mainly pains in oriental medicine. In this study, analytical method for the quantitative determination of the eleven marker components, gallic acid (1), oxypaeoniflorin (2), paeoniflorin (3), albiflorin (4), liquiritin (5), isoliquiritin (6), ononin (7), liquiritigenin (8), benzoylpaeoniflorin (9), paeonol (10), and glycyrrhizin (11) in Jakyakgamcho-tang decoction was performed using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The analytical column for separation of the compounds 1~11 was used an UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and column oven temperature was maintained at $45^{\circ}C$. The mobile phase consisted of 0.1% (v/v) aqueous formic acid (A) and acetonitrile (B) by gradient elution. The flow rate was 0.3 ml/min and injection volume was $2.0{\mu}l$. Correlation coefficient in the calibration curves of the compounds 1~11 were showed a good linearity with more than 0.99. The limit of detection and limit of quantification values of the compounds 1~13 were detected in the ranges 0.06~18.43 ng/ml and 0.18~58.29 ng/ml, respectively. Among the compounds 1~11, the compounds 10 were not detected in this sample, while the ten compounds, 1~9 and 11, were detected $44.05{\sim}19,289.05{\mu}g/g$ in Jakyakgamcho-tang extract.

Simultaneous Analysis of Bioactive Metabolites from Caulis Lonicera japonica by HPLC-DAD-ion trap-MS (HPLC-DAD-ion trap-MS를 이용한 인동 생리활성 물질의 동시분석)

  • Ryu, Sung-Kwang;Won, Tae-Hyung;Kang, Sam-Sik;Shin, Jong-Heon
    • YAKHAK HOEJI
    • /
    • v.54 no.3
    • /
    • pp.157-163
    • /
    • 2010
  • A high-performance liquid chromatography (HPLC) with DAD detector and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of coniferin (1), loganic acid (2), demethylsecologanol (3), sweroside (4) and loganin (5) from caulis Lonicera joponica. The optimal chromatographic conditions were obtained on an ODS column ($5{\mu}m$, $4.6{\times}150mm$) with the column temperature $35^{\circ}C$. The mobile phase was composed of (A) water with 0.1% formic acid and (B) methanol with 0.1% formic acid using a gradient elution, the flow rate was 0.3 ml/min. Detection wavelength was set at 254 nm. All calibration curves showed good linear regression ($r^2$>0.998) within test ranges. The developed method provided satisfactory precision and accuracy with overall intra-day and interday variations of 0.16~3.28% and 0.14~1.99%, respectively, and the overall recoveries of 99.39~105.89% for the five compounds analyzed. The verified method was successfully applied to quantitative determination of the two types (phenolic compounds and iridoids) of bioactive compounds in 24 commercial caulis L. japonica samples from different markets in Korea and China. The analytical results demonstrated that the contents of the five analytes vary significantly with sources.

Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry (불꽃원자 흡수 분광법으로 활성탄소에 흡착된 메틸티몰 블루로 납(II)의 예비농축, 분리 및 측정)

  • Ensafi, Ali A.;Ghaderi , Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO3 solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 g mL-1. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

Treatment of Experimental Hydronephrosis Using Renal Artery Embolization and Sclerotherapy in Beagle Dogs (신동맥색전술과 신우경화술을 이용한 비글견의 실험적 수신증 치료)

  • Chang Dong-woo;Lee Young-won;Shin Sang-tae
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.119-124
    • /
    • 2005
  • This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) and sclerotherapy of renal pelvis using iohexol-ethanol solution in dogs with unilateral experimental hydronephrosis. Experimental hydronephrosis was induced by unilateral ureter ligation for 20 days in five Beagle dogs. Renal artery embolization with iohexol-ethanol solution was performed using selective catheterization technique in the hydronephrotic kidney and sclerotherapy was done by injection of the iohexol-ethanol solution through percutaneously placed pig-tail catheter. EKG, $SpO_2$ body temperature, pulse, and respiratory rate were within normal ranges during procedures. Average pure ethanol dose for renal artery embolization was $1.1\pm0.3ml/kg$. Renal artery embolization was confirmed by the detection of no blood flow signal at the interlobar and arcuate artery using color Doppler ultrasonography. There were no dogs expired after TAE-RA and sclerotherapy and no side effects associated with regurgitation of iohexol-ethanol solution. The value of BUN, creatinine, ALT, AST, Ca, P in five dogs were within normal range during the experiment period. Ultrasonographically, the mean longitudinal and transverse length and the depth of the embolized kidney significantly decreased at 28 days after TAE-RA. We may conclude that TAE-RA and sclerotherapy with iohexol-ethanol solution is an effective methods for the treatment of unilateral hydronephrosis in dogs.

Rapid High Performance Liquid Chromatographic Quantification of Major Isoflavones in Soybeans and Soybean Pastes

  • Kim, Won-Chan;Kwon, Soon-Ho;Rhee, In-Koo;Hur, Jong-Moon;Jeong, Hyun-Hee;Choi, Sun-Ha;Lee, Kyung-Bok;Kang, Young-Hwa;Song, Kyung-Sik
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.24-27
    • /
    • 2006
  • A simple HPLC quantification method was developed for genistein, genistin, daidzein, and daidzin in soybeans and soybean products. The procedure used a $4.6{\times}100\;mm$ $Chromolith^{(R)}$ RP-18e column with a mobile phase of 1% HOAc in 20% MeOH to 1% HOAc in 80% MeOH for 10 min. The injection volume was $2\;{\mu}L$ at a flow rate of 2 mL/min. Detection was carried out under UV at 254 nm. Under these conditions, the major isoflavones daidzein, daidzin, genistein, and genistin in soybean and soybean pastes were eluted within 7 min with baseline separation. Optimal extraction of the above four major isoflavones was achieved when 40 g of soybean or soybean paste was refluxed in 100 mL of 95% ethanol for 2 hr. Ten different soybean cultivars and nine commercial soybean pastes were analyzed by this method. The total isoflavone content was highest in the cultivar Somyung ($2,497\;{\mu}g/g$ dry weight). The isoflavone content in soybean pastes varied widely from manufacturer to manufacturer (an almost five-fold difference between the highest and lowest values). Such variations were presumably due to differences in fermentation conditions, type of soybeans used, and levels of such additives as starch and salt.

A Study of the SPWM High-Frequency Harmonic Circulating Currents in Modular Inverters

  • Xu, Sheng;Ji, Zhendong
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2119-2128
    • /
    • 2016
  • Due to detection and control errors, some high-frequency harmonics with voltage-source characteristics cause circulating currents in modular inverters. Moreover, the circulating currents are usually affected by the output filters (OF) of each module due to their filter and resonance properties. The interaction among the circulating currents in the modules increase the power loss and reduce system stability and control precision. Therefore, this paper reports the results of a study on the SPWM high-frequency harmonics circulating currents for a double-module VSI. In the paper, an analysis of the circulating-current circuits is briefly described. Next, a mathematic model of the single-module output voltage based on the carrier frequency of SPWM is built. On this basis, through mathematic modeling of high-frequency harmonic circulating currents, the formation mechanism and distribution characteristics of circular currents and their influences are studied in detail. Finally, the influences of the OF on the circulating currents are studied by mainly taking an LC-type filter as an example. A theoretical analysis and experimental results demonstrate some important characteristics. First, the carrier phase shifting of the SPWM for each module is the major cause of the SPWM harmonic circulating currents, and the circulating currents are in an odd distribution around n-times the carrier frequency $n{\omega}_s$, where n = 1, 2, 3, ${\ldots}$. Second, the harmonic circular currents do not flow into the parallel system. Third, the OF can effectively suppress the non-circulating part of the high-frequency harmonic currents but is ineffective for the circulation part, and actually reduces system stability.

Simultaneous Determination of Doxifluridine and 5-FU in Liver and Intestine Tissue Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 및 비글견의 간 및 장관 조직에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Jeong, Eun-Ju;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • A liquid chromatographic method with tandom spectrometric detection (LC/MS/MS) for the simultaneous determination of doxifluridine and its active metabolite, 5-fluorouracil (5-FU) was developed over the concentration range of $5{\sim}2000$ ng/ml, respectively. Doxifluridine, 5-FU and internal standard, 5-chlorouracil (5-CU), were extracted from liver and intestine tissue via protein precipitation. Acetonitrile was used as the extraction solvent and the supernatant was evaporated and reconstructed in mobile phase. Optimum chromatographic separation was achieved on a Agilent Zorbax $C_{18}$ ($100\;mm{\times}2.1\;mm$, $3.5\;{\mu}m$) column with mobile phase run in isocratic with methanol : water (20 : 80, v/v). The flow rate was 0.2 ml/min with total cycle time of 5 min. The lower limit of quantification was validated at 5.0 ng/ml of liver and intestine tissue, for both doxifluridine and 5-FU, respectively. The intra-day and inter-day precision and accuracy of quality control (QC) samples were <11% coefficient of variation and <7% relative error from theoretical concentration for both analytes. In addition, the special designed stability study was performed, because the metabolism of doxifluridine occurs spontaneously even in ice bath for monkey liver. The stability of doxifluridine in liver and intestine of monkey and beagle dog was compared. It was found that bioanalytical validation could not be performed for the monkey liver; however, beagle dog's liver has relatively low speed of metabolism compared to monkey liver and instead of monkey liver, beagle dog's liver could be used for the validation. Bioanalytical validation could be performed in monkey intestine. Eventually, this developed method for liver and intestine will be useful in support of the toxicokinetic and pharmacokinetic studies of doxifluridine and 5-FU.