• Title/Summary/Keyword: Flow Control System

Search Result 3,067, Processing Time 0.032 seconds

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Approaches to Applying Social Network Analysis to the Army's Information Sharing System: A Case Study (육군 정보공유체계에 사회관계망 분석을 적용하기 위한방안: 사례 연구)

  • GunWoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.597-603
    • /
    • 2023
  • The paradigm of military operations has evolved from platform-centric warfare to network-centric warfare and further to information-centric warfare, driven by advancements in information technology. In recent years, with the development of cutting-edge technologies such as big data, artificial intelligence, and the Internet of Things (IoT), military operations are transitioning towards knowledge-centric warfare (KCW), based on artificial intelligence. Consequently, the military places significant emphasis on integrating advanced information and communication technologies (ICT) to establish reliable C4I (Command, Control, Communication, Computer, Intelligence) systems. This research emphasizes the need to apply data mining techniques to analyze and evaluate various aspects of C4I systems, including enhancing combat capabilities, optimizing utilization in network-based environments, efficiently distributing information flow, facilitating smooth communication, and effectively implementing knowledge sharing. Data mining serves as a fundamental technology in modern big data analysis, and this study utilizes it to analyze real-world cases and propose practical strategies to maximize the efficiency of military command and control systems. The research outcomes are expected to provide valuable insights into the performance of C4I systems and reinforce knowledge-centric warfare in contemporary military operations.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

The Development of HACCP-Based Standardized Recipe and the Quality Assessment of Cook/Chilled Soy Sauce Glazed Mackerel (쿡췰(Cook/Chill)시스템을 이용한 고등어조림의 HACCP 레시피 개발 및 생산과정의 품질평가)

  • Kwak, Tong-Kyung;Lee, Kyung-Eun;Park, Hye-Won;Ryu, Kyung;Hong, Wan-Soo;Choi, Eun-Jung;Jang, Hye-Ja;Kim, Sung-Hee
    • Korean journal of food and cookery science
    • /
    • v.13 no.5
    • /
    • pp.592-601
    • /
    • 1997
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled soy sauceglazed mackerel and to evaluate the qualities related to the product flow of this item. After conducting experimental cooking, preliminary test, and analysis of recipes, critical control points were identified, control methods were determined, and HACCP-based recipe was standardized. At each critical control point, time-temperature profile was recorded and microbiological analysis (total aerobic plate counts, psychrotrophic plate count, coliform, and fecal coliform count), chemical analysis (pH, acid value and volatile based nitrogen (VBN)) and sensory evaluation of the item were done. Time-temperature data showed that the time the menu item had passed through temperature danger zone (5∼60$^{\circ}C$) during all phases was 60 min. At rapid cooling, but after cooling at room temperature, the temperature of this menu item did not drop below the ambient temperature. The results of microbiological test were negative throughout all phases following cooking and the results of chemical analysis did not change significantly in terms of storage periods except for VBN which increased on 7th day significantly(p<0.05). After steam/convection oven reheating and microwave oven reheating, the sensory score of the only appearance decreased significantly related to the storage time of overall quality profiles. But significant differences were not detected according to two reheating methods. In conclusion, this HACCP-based recipe was considered as an effective tool for assuring microbial as well as sensory quality of this cook/chilled item.

  • PDF

Experimental Study of the Pancreatic Regeneration after Partial Pancreatectomy in Rat (취조직 재생능에 관한 실험)

  • Lee, M.S.;Lee, S.Y.
    • The Korean Journal of Pharmacology
    • /
    • v.14 no.1_2
    • /
    • pp.47-54
    • /
    • 1978
  • Recently, a major resection of the pancreas has been carried out not only to treat carcinoma of pancreas but also chronic pancreatitis. But limited and often contradictory reports have been made on the exocrine effects after partial surgical pancreatectomy in mammals. It was suggested that the growth of the residual tissue in pancreatectomized rat is very active, because pancreas has the great power of regeneration after partial pancreatectomy, while others observed that rat pancreas after partial surgical resection revealed a perplexing mixture of atrophy and regeneration of acinar tissue. On the other hand, another results showed that the amount of insulin required to control diabetes after partial resection of pancreas is much greater than that needed after total pancreatectomy. Because the anti-insulin system, such as glucagon secretion and hypophyseoadrenal function, is probably depressed after total pancreatectomy. Furthermore, minimal resection line which will not influence the normal function of pancreas is not agreeable, such 75%, 80% or 95% resection of the total pancreas in rat. So far, studies on the exocrine function other than endocrine function after partial pancreatectomy have been limited. Therefore, the main purpose of this study is to examine the changes of exocrine as well as endocrine function of pancreas at the different time interval after 60% or 80% pancreatectomy in rats. The results summerized as follow: 1) In both 60% and 80% resected groups, a slight decrease of the total body weight was observed at a day after partial pancreatectomy in rats, but the body weight was continued to increase for following 100 days. 2) The weight of residual pancreas was continuously increased during experiment in both 60% and 80% resected groups. But the content of tissue protein in residual pancreas was significantly decreased comparing with those of resected pancreas. 3) The flow rate of pancreatico-biliary juice was significantly decreased immediately after pancreatectomy in both resected groups. But it was recovered to control level after a day in 60% resected group, after 30 days in 80% resected group. 4) The output of amylase and lipase in resected groups were significantly decreased right after pancreatectomy comparing with control group. In the 60% resected group, the output of amylase was recovered during the following 100 days after pancreatectomy, while lipase output in 3 days. However, in the 80% resected group, the output of amylase and lipase were not recovered during 100 days after pancreatectomy. 5) In order to examine the endocrine function, blood sugar level were examined at all experimental periods after partial pancreatectomy. There was no difference between control and 60% resected group in the sugar level. But in the 80% resected group the level was significantly incresed immediately after pancreatectomy, and reached the highest level at 3 days. Then it was decreased to control level during the next 10 days after pancreatectomy. The above results showed that in 60% resected group little changes were observed on pancreatic function, but severe functional impairments were observed in 80% resected group. This results suggested that the endocrine function was recovered within a short period, although the exocrine function was not recovered for a long time after 80% pancreatectomy in rats.

  • PDF

THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN (유동성 레진의 두께가 미세누출에 미치는 영향)

  • Song, Gi-Gang;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.363-371
    • /
    • 2005
  • This study investigated the effect of thickness of flowable resin lining on marginal leakage in class II composite restorations. 80 experimental teeth were prepared with class II preparations with enamel margin or dentin margin. Each group was devided into four groups according to flowable resin lining thickness ; Control group - no flowable resin lining, Group 1 - 0.5 mm flowable resin lining, Group 2 - 1 mm flowable resin lining, Group 3 - 2 mm flowable resin lining. The cavities were restored using Scotchbond Multi-Purpose adhesive system, Filtek Flow and Filtek Z 250 composite resin. Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles and immersed in $2\%$ methylene blue for 24 hours. The results of this study were as follows : 1. Ranking of mean microleakage scores at the enamel margins was Group 1 < Control = Group 2 < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 and Group 2 (p < 0.05). 2. Ranking of mean microleakage scores at the dentin margins was Group 1 < Group 2 < Control < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 (p < 0.05) 3. Compared with microleakage between the enamel and dentin margins, enamel margin group were significantly lower than dentin margin group.

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Pilot Evaluation for the Introduction of Ecosystem Accounting for Flood Control (홍수조절 생태계 계정 도입을 위한 전국 단위 시범 평가)

  • Tae-Ho Lee;Hee-Jin Moon;Gumsung Cheon;Jung-In Kim
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.488-502
    • /
    • 2023
  • Ecosystem service accounting must measure ecosystem supply functions, demand, and the actual service flows that occur between them. In order to measure flows, supply and demand relationships must be defined, and a methodology that can objectify complex connections is needed. Although various studies on ecosystem services have been conducted in Korea, but researches on accounting for ecosystem services are not enough. The purpose of this study is to evaluate flood control ecosystem services by applying the EU methodology studied in the Experimental Ecosystem Account (EEA) of System of Environmental Economy Account (SEEA) and explore ways to introduce ecosystem account. To conduct the study, the ecosystem's runoff retention potential, social and economic demand for flood control, and actual service benefit flows formed from the relationships between them were modeled and quantified on a spatial basis. As a result of calculating the actual flow of flood control ecosystem services, the total domestic service amount was calculated to be 165,595 (ha), and it was confirmed that much of it was concentrated in agricultural land. In order to account for domestic flood control services in the future, key spatial data such as land cover maps must be continuously established and managed, and researches on input data and methodologies applicable to various spatial scopes such as national, regional, and unit watersheds are expected to be necessary.

Modeling and Intelligent Control for Activated Sludge Process (활성슬러지 공정을 위한 모델링과 지능제어의 적용)

  • Cheon, Seong-pyo;Kim, Bongchul;Kim, Sungshin;Kim, Chang-Won;Kim, Sanghyun;Woo, Hae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1905-1919
    • /
    • 2000
  • The main motivation of this research is to develop an intelligent control strategy for Activated Sludge Process (ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of wastewater, the change in influent flow rate, weather conditions, and etc. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP is generally controlled by a PID controller that consists of fixed proportional, integral, and derivative gain values. The PID gains are adjusted by the expert who has much experience in the ASP. The ASP model based on $Matlab^{(R)}5.3/Simulink^{(R)}3.0$ is developed in this paper. The performance of the model is tested by IWA(International Water Association) and COST(European Cooperation in the field of Scientific and Technical Research) data that include steady-state results during 14 days. The advantage of the developed model is that the user can easily modify or change the controller by the help of the graphical user interface. The ASP model as a typical nonlinear system can be used to simulate and test the proposed controller for an educational purpose. Various control methods are applied to the ASP model and the control results are compared to apply the proposed intelligent control strategy to a real ASP. Three control methods are designed and tested: conventional PID controller, fuzzy logic control approach to modify setpoints, and fuzzy-PID control method. The proposed setpoints changer based on the fuzzy logic shows a better performance and robustness under disturbances. The objective function can be defined and included in the proposed control strategy to improve the effluent water quality and to reduce the operating cost in a real ASP.

  • PDF