• Title/Summary/Keyword: Flow Control System

Search Result 3,071, Processing Time 0.036 seconds

Bq-ZSI fed Induction Motor Drive System Using Modified Space Vector Modulation (변형 공간벡터 변조 기법이 적용된 Bq-ZSI를 이용한 유도전동기 구동시스템)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • This study investigates a bidirectional quasi-Z-source inverter (Bq-ZSI) system with bidirectional power transfer capability and a modified space vector modulation scheme for reducing the ripple of the inductor current. By replacing the diode in the impedance network with an active switch, the power flow can be bidirectional. The average inductor current of the Bq-ZSI network is negative in the regenerative braking mode, thereby regenerating the power. In addition, modified space vector modulation scheme is applied to the Bq-ZSI to control shoot-through time effectively. A 5 kW prototype is built and tested to implement the proposed system. Experimental results show that the Bq-ZSI system is capable of regenerative braking of the induction motor and that the modified space vector modulation method is efficient.

A study on the Vibration Damping of a gun barrel using Dynamically Tuned Shroud (차열관을 이용한 포신의 진동 감쇠에 대한 연구)

  • Koh, Jae-Min;Kim, Kyeon-Sik;Kim, Jin-Woo;Jung, Hyun-Woo;Hwang, Jai-Hyuk;Bae, Jai-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.4 no.4
    • /
    • pp.28-36
    • /
    • 2010
  • Current tanks have been developed to increase mobility and firepower, and its maximum range and destructive power are improved. This great change causes remained vibration of a gun barrel after firing. For this reason, people are trying to control vibration of gun barrel effectively. This thesis presents a modeling method and analysis results for gun barrel by using a thermal shroud as an absorber mass. DTS(Dynamically Tuned Shroud) is a vibration damping system using a thermal shroud as an added mass for decreasing remained vibration. The model has an advantage that the gun barrel's vibration can be decreased by dissipating a kinetic energy of thermal shroud without install an additional dynamic absorber to tip of the gun barrel. For analyzing the damping performance of the DTS, We derived an equation of motion of the barrel after setting a mathematical modeling, and found out the frequency analysis and tendency according to stiffness ratio between barrel and shroud.

  • PDF

UPFC Device: Optimal Location and Parameter Setting to Reduce Losses in Electric-Power Systems Using a Genetic-algorithm Method

  • Mezaache, Mohamed;Chikhi, Khaled;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Ensuring the secure operation of power systems has become an important and critical matter during the present time, along with the development of large, complex and load-increasing systems. Security constraints such as the thermal limits of transmission lines and bus-voltage limits must be satisfied under all of a system’s operational conditions. An alternative solution to improve the security of a power system is the employment of Flexible Alternating-Current Transmission Systems (FACTS). FACTS devices can reduce the flows of heavily loaded lines, maintain the bus voltages at desired levels, and improve the stability of a power network. The Unified Power Flow Controller (UPFC) is a versatile FACTS device that can independently or simultaneously control the active power, the reactive power and the bus voltage; however, to achieve such functionality, it is very important to determine the optimal location of the UPFC device, with the appropriate parameter setting, in the power system. In this paper, a genetic algorithm (GA) method is applied to determine the optimal location of the UPFC device in a network for the enhancement of the power-system loadability and the minimization of the active power loss in the transmission line. To verify our approach, simulations were performed on the IEEE 14 Bus, 30 Bus, and 57 Bus test systems. The proposed work was implemented in the MATLAB platform.

Simulation of the flow characteristics of R1234yf flowing through capillary tubes (냉매 R1234yf의 모세관내 유동 특성에 관한 해석적 연구)

  • Kim, Daeyeong;Park, Chasik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6452-6457
    • /
    • 2014
  • R1234yf has been developed as an alternative refrigerant to R134a, which has been associated with global warming. The capillary tubes as expansion valves control the mass flow rate and balance system pressure in the refrigeration cycle. The present numerical model used the governing equations including the law of conservation of mass, momentum, and energy in a capillary tube. The mass flow rate of R1234yf decreased by 47.0% as the capillary tube length was increased from 1 to 4 m. As the inner diameter of the capillary tubes was changed from 1.3 to 1.7 mm, the mass flow rate of R134a and R1234yf increased by 117.9% and 121.0%, respectively. The mass flow rate of the R134a and R1234yf increased by 28.3% and 29.1% with subcooling increasing from 0 to $7^{\circ}C$. In addition, when the inlet temperature of the capillary tubes was changed from 35 to $60^{\circ}C$, the mass flow rate of R134a and R1234yf increased by 31.0% and 45.4%, respectively.

Flow Rate Changes in the Heterogeneous Rectangular Microchannels with Different Hydrophilicity for the PDMS Bottom Surface (PDMS 표면특성에 따른 비균일계 마이크로채널의 유속 변화)

  • Noh, Soon-Young;Lee, Hyo-Song;Kim, Ki-Ho;Choi, Jae-Ho;Yu, Jae-Keun;Yoon, Soo-Kyung;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • This study investigated the flow rate changes of the heterogeneous rectangular microchannels which have different hydrophilic property on the bottom surface. The heterogeneous rectangular microchannel has three native PDMS (poly-dimethyl siloxane) surfaces which were patterned by the soft lithography. PDMS bottom surface was treated by the argon plasma and coated by the allyl alcohol (99%). The channel length was 10, 20 and 30 mm and the channel width was 100, 200 and $300\;{\mu}m$, respectively. Several external voltages were applied to make the fluid flow by the electroosmosis in the microchannel. For the same electric field strength and hydrophilicity of the bottom surface, the flow rate is almost same. This result is matched to the theoretical expectation and confirms that the experimental system is reliable. With increasing the channel width, the flow rate increased for the same hydrophilicity of the bottom surface. The flow rate of the microchannel of higher hydrophilicity was larger than that of the microchannel of lower hydrophilicity. This result implies that the hydrophilicity change of the bottom surface could be applied to control the flow rate in the microchannel.

  • PDF

Estimation of stream flow discharge using the satellite synthetic aperture radar images at the mid to small size streams (합성개구레이더 인공위성 영상을 활용한 중소규모 하천에서의 유량 추정)

  • Seo, Minji;Kim, Dongkyun;Ahmad, Waqas;Cha, Jun-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.12
    • /
    • pp.1181-1194
    • /
    • 2018
  • This study suggests a novel approach of estimating stream flow discharge using the Synthetic Aperture Radar (SAR) images taken from 2015 to 2017 by European Space Agency Sentinel-1 satellite. Fifteen small to medium sized rivers in the Han River basin were selected as study area, and the SAR satellite images and flow data from water level and flow observation system operated by the Korea Institute of Hydrological Survey were used for model construction. First, we apply the histogram matching technique to 12 SAR images that have undergone various preprocessing processes for error correction to make the brightness distribution of the images the same. Then, the flow estimation model was constructed by deriving the relationship between the area of the stream water body extracted using the threshold classification method and the in-situ flow data. As a result, we could construct a power function type flow estimation model at the fourteen study areas except for one station. The minimum, the mean, and the maximum coefficient of determination ($R^2$) of the models of at fourteen study areas were 0.30, 0.80, and 0.99, respectively.

Improvement of Cooling Efficiency in Greenhouse Fog System Using the Dehumidifier (제습기를 이용한 온실 포그냉방시스템의 효율향상)

  • Nam Sang Woon;Kim Kee Sung;Giacomelli Gene A.
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • In order to provide fundamental data on utilization of dehumidifier in greenhouses, a condensing type dehumidifier using ground water as a coolant was developed and tested dehumidification performance. The developed dehumidifier was applied to greenhouse with fog cooling system and effect of dehumidification on improvement of evaporative cooling efficiency was analyzed. Results of the dehumidifier performance test showed that dehumidification using ground water as a coolant was sufficiently possible in fog cooling greenhouse. When the set point temperature of greenhouse cooling was $32^{\circ}C$ and as temperatures of ground water rose from $15^{\circ}C\;to\;18^{\circ}C,\;21^{\circ}C\;and\;24^{\circ}C$, dehumidification rates decreased by $17.7\%,\;35.4\%\;and\;52.8\%$, respectively. As flow rates of ground water reduced to $75\%\;and\;50\%$, dehumidification rates decreased by $12.1\%\;and\;30.5\%$, respectively. Cooling efficiency of greenhouse equipped with fog system was distinctly improved by artificial dehumidification. When the ventilation rate was 0.7 air exchanges per minute, dehumidification rates of the fog cooling greenhouse caused by natural ventilation were 53.9%-74.4% and they rose up to 75.4%-95.9% by operating the dehumidifier. In case of using the ground water of $18^{\circ}C$ and flow rate of design condition, it was analyzed that whole fog spraying water can be dehumidified even if the ventilation rate is 0.36 exchanges per minute. As a utilization of dehumidifier, it is possible to improve cooling efficiency of fog system in naturally ventilated greenhouses.

Design and implementation of motion tracking based no double difference with PTZ control (PTZ 제어에 의한 이중차영상 기반의 움직임 추적 시스템의 설계 및 구현)

  • Yang Geum-Seok;Yang Seung Min
    • The KIPS Transactions:PartB
    • /
    • v.12B no.3 s.99
    • /
    • pp.301-312
    • /
    • 2005
  • Three different cases should be considered for motion tracking: moving object with fixed camera, fixed object with moving camera and moving object with moving camera. Two methods are widely used for motion tracking: the optical flow method and the difference frame method. The optical new method is mainly used when either one, object or camera is fixed. This method tracks object using time-space vector which compares object position frame by frame. This method requires heavy computation, and is not suitable for real-time monitoring system such as DVR(Digital Video Recorder). The different frame method is used for moving object with fixed camera. This method tracks object by comparing the difference between background images. This method is good for real-time applications because computation is small. However, it is not applicable if the camera is moving. This thesis proposes and implements the motion tracking system using the difference frame method with PTZ(Pan-Tilt-Zoom) control. This system can be used for moving object with moving camera. Since the difference frame method is used, the system is suitable for real-time applications such as DVR.

Unified Design Methodology and Verification Platform for Giga-scale System on Chip (기가 스케일 SoC를 위한 통합 설계 방법론 및 검증 플랫폼)

  • Kim, Jeong-Hun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.106-114
    • /
    • 2010
  • We proposed an unified design methodology and verification platform for giga-scale System on Chip (SoC). According to the growth of VLSI integration, the existing RTL design methodology has a limitation of a production gap because a design complexity increases. A verification methodology need an evolution to overcome a verification gap. The proposed platform includes a high level synthesis, and we develop a power-aware verification platform for low power design and verification automation using it's results. We developed a verification automation and power-aware verification methodology based on control and data flow graph (CDFG) and an abstract level language and RTL. The verification platform includes self-checking and the coverage driven verification methodology. Especially, the number of the random vector decreases minimum 5.75 times with the constrained random vector algorithm which is developed for the power-aware verification. This platform can verify a low power design with a general logic simulator using a power and power cell modeling method. This unified design and verification platform allow automatically to verify, design and synthesis the giga-scale design from the system level to RTL level in the whole design flow.

In-situ Methane Enrichment System Coupled with External $CO_2$ Stripper in Mesophilic Anaerobic Digestion (중온혐기성소화조에서 외부 $CO_2$ Stripping을 이용한 In-situ 고순도 메탄회수 공정 개발)

  • Kang, Ho;Jeong, Ji-Hyun;Lim, Seon-Ae;Lee, Hye-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.155-161
    • /
    • 2012
  • A simple in-situ methane enrichment system in mesophilic anaerobic digestion was developed to take advantage of the differing solubilities of $CO_2$ and methane. The methane enhancement systems consisted of low solids plug-flow maize digester coupled with a leachate recycle loop to an external $CO_2$ stripper. The effects of leachate recycle rate (LRR) and reactor alkalinity on the resulting offgas $CH_4$ contents, biogas productivity and TVS removal efficiency were quantitively evaluated. The results showed that offgas $CH_4$ contents of over 94% was achieved at 3 volume of leachate recycle per volume of reactor per day (3 v/v-d) and at the reactor alkalinity of 4 g/L as $CaCO_3$, as the optimum operating conditions. The TVS removal efficiency of the methane enhancement system was 79% which corresponds to 94% of the control reactor and the methane productivity appeared to be 0.71 v/v-d. Offgas methane contents correlated well with LRR. However excessively high LRR led to the decrease in TVS removal efficiency.