• 제목/요약/키워드: Flow Capability

검색결과 747건 처리시간 0.032초

LDF의 실시간 혈류추정을 위한 알고리즘 (An algorithm for real time blood flow estimation of LDF)

  • 김종원;고한우
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.78-79
    • /
    • 1998
  • This paper describes a real time algorithm for blood flow estimation of LDF(laser Doppler flowmeter). Many algorithms for blood flow estimation are using power spectral density of Doppler signal by blood flow. In these research, the fast Fourier transformation is used to estimate power spectral density. This is a block processing procedure rather than real time processing. The algorithm in this paper used parametric spectral estimation. This has real time capability by estimation of AR(autoregressive) parameters sample by sample, and has smoothing power spectrum. Also, the frequency resolution is not limited by number of samples used to estimate AR parameter. Another advantage of this algorithm is that AR model enhance SNR.

  • PDF

The Simulation of Semicale Natural Circulation Test 5-NC-3,S-NC-4 Using RELAP5/Mod3.1

  • Kim, S. N.;W. H. Jang
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.424-434
    • /
    • 1998
  • RELAP5/Mod3.1 code was assessed with the semiscale experiment S-NC-3, and S-NC-4, which simulated the two-phase natural circulation and reflux condensation for the SBLOCA of PWR, respectively . Test S-NC-3 and S-NC-4 calculation results showed that RELAP5/Mod3.1 quite well describes the influence of steam generator secondary side heat transfer degradation on both two-phase natural circulation and reflux condensation. A comparison between the calculated and measured two-phase mass flow rate in test S-NC-3 shows good agreement for primary mass inventory more than 92%. And RELAP5/Mod3.1 have a good mass flow rate prediction capability for the transient such as S-NC-4 except some flow oscillations. The reflux flow rate for S-NC-4 test is under predicted, and the overall results verify that the correct prediction of the reduced liquid level appears to be required for the correct calculation of the overall phenomena.

  • PDF

적층 벤더형 압전식 공압밸브의 내구 특성 (Endurance of Pneumatic Valve with a Multi-bender PZT Actuator)

  • 윤소남;박인섭
    • 동력기계공학회지
    • /
    • 제18권2호
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

Dynamic Load-Balancing Algorithm Incorporating Flow Distributions and Service Levels for an AOPS Node

  • Zhang, Fuding;Zhou, Xu;Sun, Xiaohan
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.466-471
    • /
    • 2014
  • An asynchronous optical packet-switching (AOPS) node with load-balancing capability can achieve better performance in reducing the high packet-loss ratio (PLR) and time delay caused by unbalanced traffic. This paper proposes a novel dynamic load-balancing algorithm for an AOPS node with limited buffer and without wavelength converters, and considering the data flow distribution and service levels. By calculating the occupancy state of the output ports, load state of the input ports, and priorities for data flow, the traffic is balanced accordingly. Simulations demonstrate that asynchronous variant data packets and output traffic can be automatically balanced according to service levels and the data flow distribution. A PLR of less than 0.01% can be achieved, as well as an average time delay of less than 0.46 ns.

국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구 (A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow))

  • 임기원
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

터빈 사이클의 보정 성능 계산을 위한 급수 유량의 검증 모델 (Verification Model of the Feedwater Flow for the Calculation of Corrective Performance of Turbine Cycle)

  • 김성근;양학진;이강희;최광희
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.538-544
    • /
    • 2012
  • Analysis of thermal performance is required for the economic operation of turbine cycle of power plant. We developed corrective model of main feed water flow which is the most important parameter for the precise analysis of turbine cycle performance. Classification model for the identification of feed water flow measurement status was applied to increase the suitability of the corrective model. We used neural network and support vector machine to develop estimation model of main feed water flow with more generalization capability. The estimation model can be used practically to evaluate corrective performance of turbine cycle plant.

DFM 개념을 적용한 MEMS design flow (MEMS Design Flow Based on DFM Concept)

  • 한승오;오박균
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1466-1470
    • /
    • 2007
  • MEMS design flow based on DFM concept is presented and applied to gyroscope design as a test case. It is purposed to contribute to the yield improvement by considering the process-related parameters from the design phase. After defining the performance requirements, the sensitivity analysis should be done on the draft design(s) to find out the key parameters related with the device performance. By doing so, TEG can be designed for the selected process and/or material parameters. Through a set of test runs, the process capability is characterized and the material properties are extracted using the TEG. Then we can estimate the virtual yield of the current process for the designed device by running Monte Carlo analysis where the process and/or material property variations are considered. The estimated yield will make us redesign the device to be more robust or improve the current process to have the smaller variations.

도로 빗물받이의 차집능력 분석 (An analysis of interception capability of storm water grate inlet in road)

  • 이종태;윤세의;김갑수;김영란;류택희
    • 한국수자원학회논문집
    • /
    • 제36권3호
    • /
    • pp.465-480
    • /
    • 2003
  • 본 연구에서는 도로의 측구 부분을 수리모형으로 제작하여 빗물받이의 차집능력을 검토하였다. 측구의 유량은 도로의 차선(2-4차선) 및 빗물받이 간격(10-30m)을 고려하여 4-15l/sec의 유량을 사용하였고, 도로의 종방향 경사는 0, 2, 5, 7%를 선택하였으며, 측구의 횡경사는 4, 7, 10%를 사용하였다. 유입부의 규모는 $30\times40cm,\;40\times50cm,\;40\times100cm,\;40\times150cm$의 4종류를 사용하였으며, 총 실험 횟수는 240회이다. 측구의 횡경사가 클수록 전체적인 빗물받이의 차집유량은 증가하였다. 차집효율은 흐름폭과 유량이 작을 수록 증가하였고, 종방향 경사가 급할 수록 감소함을 알 수 있었다. 실험의 결과로부터 유입부 규모에 따른 차집유량을 계산할 수 있는 경험식을 제시하였다. 도로의 차선별, 종경사별, 측구의 횡경사별, 유입부 규모별로 적정 빗물받이 간격을 제시할 수 있어서 도로의 빗물받이 설계에 기초자료를 제공하였다.

금속분말 사출성형 제품의 공정능력분석에 관한 연구 (A Study on the Process Capability Analysis of MIM Product)

  • 최병기;이동길;최병희
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.57-64
    • /
    • 2010
  • Metal Injection Molding (MIM) is attractive because it produces consistent, complex-geometry components for high-volume, high-strength, and high-performance applications. Also MIM using in optical communication field, display field, and semi-conductor field is a cost-effective alternative to metal machining or investment casting parts. It offers tremendous single-step parts consolidation potential and design flexibility. The objective of this paper is to study the suitability of design, flow analysis, debinding and sinterin processes, and capability analysis. The suitable injection conditions were 0.5~1.5 second filling time, 11.0~12.5 MPa injection pressure derived from flow analysis. The gravity of the product is measured after debinding an sintering. The maximum and minimum gravity levels are 7.5939 and 7.5097. the average and standard deviation are 7.5579 and 0.0122; when converted into density, the figure stands at 98.154%. According to an analysis of overall capacity, PPM total, which refers to defect per million opportunities(DPMO), stands at 166,066.3 Z.Bench-the sum of defect rates exceeding the actual lowest and highest limits-is 0.97, which translates into the good quality rate of around 88.4% and the sigma level of 2.47.

양산천 수위-유량관계 특성에 관한 연구 (A Study on Characteristics of Stage-discharge Relationship for Yangsan River)

  • 이용희;이상배
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.91-98
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial of 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372$H^2$, which is discovered to be most excellent among other curves in reliability analysis. The capability of the observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and its capability to reproduce discharge was investigated and compared with the computational results. Rating curve stability is determined on the basis of deviations in the stage-discharge relationship, utilization of specific gauge, and absolute differences between sequential stream flow measurements and an analysis residuals. Therefore it seems necessary to research method to obtain rating curve in a rigorous and accurate manner.

  • PDF