• 제목/요약/키워드: Flow Analysis

검색결과 17,923건 처리시간 0.043초

Hybrid Type Vibration Power Flow Analysis Method Using SEA Parameters

  • 박영호;홍석윤
    • 한국음향학회지
    • /
    • 제21권4호
    • /
    • pp.164-164
    • /
    • 2002
  • This paper proposes a hybrid method for vibration analysis in the medium to high frequency ranges using Power Flow Analysis (PFA) algorithm and Statistical Energy Analysis (SEA) coupling concepts. The main part of the developed method is the application of coupling loss factor (CLF) suggested in SEA to the power transmission, reflection coefficients in PI' A boundary conditions. The developed hybrid method shows very promising results with regard to the applications for the various damping loss factors in wide frequency ranges. And also this paper presents the applied results of Power Flow Finite Element Method (PFFEM) by forming the new joint element matrix with CLF to analyze the various plate structures in shape. The analytical results of automobile, complex plate structures show good agreement with those of PFFEM using the PFA coefficients.

배열회수보일러 입구 덕트 확관 형상 변화에 따른 전열관군 전단 유동균일화 특성 (Characteristics of Flow Uniformity at the Section before Tube Bank with the Change of Expansion Inlet Duct Shape in a Heat Recovery Steam Generator)

  • 하지수
    • 한국가스학회지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2012
  • 복합 화력발전소 배열회수보일러에서의 입구 덕트 확관 형상 변화에 따른 전열관군 전단에서의 유동 균일화 특성을 유동수치해석을 통하여 분석하였다. 배열회수보일러의 입구는 가스터빈 후류의 출구에 해당하고 가스터빈 후류는 강한 선회 및 난류 유동이다. 본 연구에서 배열회수 보일러 입구 유동 경계조건은 가스터빈을 통과한 출구 유동 해석 결과를 이용하여 수행하였다. 배열회수보일러의 전열관군 전단에서의 유동 균일화 특성이 배열회수 보일러의 효율에 직결되므로 입구 덕트 확관 변곡점의 위치 변화에 따라 유동 균일화 특성을 파악함으로써 배열회수 보일러의 형상 최적화의 기반을 마련하는 것을 목적으로 하였다. 본 연구로부터 배열회수 보일러 확관의 변곡점의 위치가 기준 형상에서 낮은 위치에서 전열관군 전단에서 최적의 유동 균일화가 이루어짐을 알았다.

Thickness Effect on the Structural Durability of a Bileaflet Mechanical Heart Valve

  • Kwon, Young-Joo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권4호
    • /
    • pp.5-12
    • /
    • 2003
  • This paper discusses about the thickness effects on the structural durability of a bileaflet mechanical heart valve (MHV). In the study on the design and the mechanical characteristics of a bileaflet mechanical heart valve, the fluid mechanics analysis on the blood flow passing through leaflets, the kinetodynamics analysis on the rigid body motion of the leaflet induced by the pulsatile blood flow, and the structural mechanics analysis for the deformed leaflet are required sequentially and simultaneously. Fluid forces computed in the fluid mechanics analysis on the blood flow are used in the kinetodynamics analysis for the leaflet motion. Thereafter, the structural mechanics analysis for the deformed leaflet follows to predict the structural strength variation of the leaflet as the leaflet thickness changes. Analysis results show that structural deformations and stresses increase as the fluid pressure increases and the leaflet thickness decreases. Analysis results also show that the leaflet becomes structurally weaker and weaker as the leaflet becomes thinner and thinner.

사류펌프 내 삼차원 유동의 수치해석 (NUMERICAL ANALYSIS OF THREE-DIMENSIONAL FLOW IN A MIXED-FLOW PUMP)

  • 안형진;김진혁;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.223-226
    • /
    • 2009
  • This paper presents three-dimensional flow analysis for a mixed-flow pump which consists of a rotor and a stator. Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are discretized by finite volume approximations and solved by the commercial CFD code CFX 11.0. Structured grid system is constructed in the computational domain, which has O-type grids near the blade surfaces and H-type grids in other regions. Validation of the numerical results was performed with experimental data for head coefficients and hydraulic efficiencies at different flow coefficients. This paper shows that the pump characteristics can be predicted effectively by numerical analysis.

  • PDF

체강삼출액의 진단에 있어서 유세포분석에 의한 DNA 함량 측정의 유용성 (Diagnostic Value of Flow Cytometric DNA Analysis in the Evaluation of Effusions)

  • 이지신;정상우
    • 대한세포병리학회지
    • /
    • 제8권1호
    • /
    • pp.20-26
    • /
    • 1997
  • The specificity of cytologic examination in effusions is high but the sensitivity is low. Therefore, various ancillary methods for the detection of malignant cells in effusions have been proposed. The presence of an aneuploid cell population is generally considered diagnostic of malignancy. The purpose of this study is to determine whether the routine use of flow cytometry adds to standard cytologic evaluation in effusions. We did flow cytometric DNA analysis in 76 effusions(28 malignant and 48 benign fluids). All the 48 benign effusions were diploid. There were 12(42.9%) aneuploid and 16(67.1%) diploid malignant effusions. Based on these results flow cytometric DNA analysis had a sensitivity of 42.9% and a specificity of 100%. These results suggest that flow cytometric DNA analysis may be a useful adjunct to conventional cytology, but its principal limitation is us relatively low sensitivity.

  • PDF

관내 유동 해석을 위한 웹기반 자바 프로그램 개발 (DEVELOPMENT OF WEB-BASED JAVA PROGRAM FOR NUMERICAL ANALYSIS OF PIPE FLOW)

  • 김경성;박종천
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.88-94
    • /
    • 2010
  • In general, flow analysis programs have been built in not JAVA language but such as Fortran, C or C++ because of a merit in performance of computation. However, most developer of those languages are not free for use. User should purchase the development tools of programs, and install it on their own computer. Fortunately, JAVA is a free software, and can be used to develop WEB-based programs. It is well known that the JAVA language is time consuming for calculating. However, the performance of computer power has been increased continuously, so it is sure that the former states can be overcome. In the present study, a flow analysis program, which is interactive with Graphics, using the Web-based programing language, JAVA, has been developed for solving the two-dimensional flow motion.

$45^{\circ}$ 원형충돌분류의 난류혼합유동장에 대한 수치해석 (Numerical Analysis on the Turbulent Mixing Flow Field of $45^{\circ}$ Impinging Round Jet)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.38-45
    • /
    • 2011
  • The computational flow numerical analysis was introduced to predict thc turbulent characteristics in the mixing flow structure of $45^{\circ}$ impinging round jet. This analysis has been carried out through the commercial fluent software. Realizable(RLZ) k-${\varepsilon}$ was used as a turbulent model. It can be known that mean velocities analysed through RLZ k-${\varepsilon}$ turbulent model comparatively predict well the experiments and show well the elliptic shape of mixing flow structure in the Y-Z plane, but analysed turbulent kinetic energies show somewhat differently from the experiments in certain regions.

Investigation of the 2013 Hadari Debris Flow in Korea Through Field Survey and Numerical Analysis

  • Choi, Junghae
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.341-348
    • /
    • 2018
  • Landslides can be caused by localized intense rainfall. The loss of human lives and damage to property from landslides is increasing. However, little information exists on the movement and flow of sediment material at the time of rapid landslides. In this study, a field survey was conducted of landslides that occurred in 2013 in the Hadari area of Yeoju city in Korea. This was followed by numerical analysis. The purpose is to analyze the characteristics of a consequent debris flow and its movement at the time of failure. The results of the field survey and numerical analysis are consistent with each other. The maximum velocity of the debris flow was ~9.335 m/s and the maximum sediment thickness ~4.674 m. The latter is similar to the traces of debris flow observed in the field.

워터제트 선박추진용 사류펌프의 설계 및 성능해석 (Design and Performance Analysis of Mixed-Flow Pumps for Waterjet Marine Propulsion)

  • 윤의수;오형우;안종우
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.41-46
    • /
    • 2003
  • The hydraulic design optimization and performance analysis of mixed-flow pumps for waterjet marine vehicle propulsion has been carried out using mean streamline analysis and three-dimensional computational fluid dynamics (CFD) code. In the present study, the conceptual design optimization has been formulated with a non-linear objective function to minimize the fluid dynamic losses, and then the commercial CFD code was incorporated to allow for detailed flow dynamic phenomena in the pump system. Newly designed mixed-flow model pump has been tested in the laboratory. Predicted performance curves by the CFD code agree very well with experimental data for a newly designed mixed-flow pump over the normal operating conditions. The design and prediction method presented herein can be used efficiently as a unified hydraulic design process of mired-flow pumps for waterjet marine vehicle propulsion.

Microfluidic Flow Cytometry: Principles of Cell Analysis and Applications

  • Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2006
  • Microsystems create new opportunities for conventional cell analysis by combining microfluidics and flow cytometry. This article describes recent developments in conventional flow cytometers and related microfluidic flow cytometers to detect, analyze, and sort cells or particles. Flow cytometry strongly consisted of fluidics, optics and electronics requires a large space to equip various components, which are mostly the fluidic components such as compressor, fluid handling system. Adopting microfluidics into flow cytometry enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this paper, we review various efforts that take advantage of novel techniques to build microfluidic cell analysis systems with high-speed analytical capability. Highly integrated microfluidic cytometry shows great promise for basic biomedical and pharmaceutical research, and robust and portable point-of-care devices could be used in clinical settings.

  • PDF