• 제목/요약/키워드: Flow Acceleration

검색결과 432건 처리시간 0.026초

2차선 유입연결로의 서비스 수준별 가속차선 길이 산정 기준 (Guideline of Acceleration Length by Level of Service for Two Lane Entrance Ramp)

  • 문대승;장명순
    • 대한교통학회지
    • /
    • 제14권3호
    • /
    • pp.75-90
    • /
    • 1996
  • The objective of study is to examine relationship between traffic flow characteristics of two lane entrance terminal and acceleration length, and to suggest the acceleration length by level of service. The relationship between the speed ratio and the distance from the ramp appeared to be a quadratic concave from. In the case of two lane entrance ramp, the acceleration length is suggested as 1.4~2.0 times longer than the acceleration length of one lane entrance ramp. It is also recommended that acceleration length for two lane entrance ramp should be designed according to the level of service at the right most lane (level of service A : 1.4 B : 1.6 C : 1.8 D : 2.0 times of the one lane entrance ramp acceleration length) on freeway.

  • PDF

내부순환유동을 고려한 연소하는 액적들의 상호작용 (Interaction of burning droplets with internal circulation)

  • 조종표;김호영;정진택
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.183-191
    • /
    • 2004
  • The burning characteristics of interacting droplets with internal circulation in a convective flow are numerically investigated at various Reynolds numbers. The transient combustion of 2-dimensionally arranged droplets, both the fixed droplet distances of 5 radii to 40 radii horizontally and 4 radii to 24 radii vertically, is studied. The results obtained from the present numerical analysis reveal that the transient flame configuration and retardation of droplet internal motion with the horizontal or vertical droplet spacing substantially influence lifetime of interacting droplets. At a low Reynolds number, lifetime of the two droplets with decreasing horizontal droplet spacing increases monotonically, whereas their lifetime with decreasing vertical droplet spacing decreases due to flow acceleration. This flow acceleration effect is reversed when the vertical droplet spacing is smaller than 5 radii in which decreasing flame penetration depth causes the reduction of heat transfer from flame to droplets. At a high Reynolds number, however, lifetime of the first droplet is hardly affected by either the horizontal droplet spacing or flow acceleration effect. Lifetime with decreasing vertical droplet spacing increases due to reduction of flame penetration depth. Lifetime of interacting droplets exhibits a strong dependence on Reynolds number, the horizontal droplet spacing and the vertical droplet spacing and can be con-elated well with these conditions to that of single burning droplet.

  • PDF

Experimental study on heat transfer characteristics of supercritical carbon dioxide natural circulation

  • Wang, Pengfei;Ding, Peng;Li, Wenhuai;Xie, Rongshun;Duan, Chengjie;Hong, Gang;Zhang, Yaoli
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.867-876
    • /
    • 2022
  • An experimental study has been conducted to investigate the heat transfer characteristics of supercritical carbon dioxide (sCO2) uniformly heated in the horizontal circular smooth tube. The results illustrated that there was a significant difference in heat transfer between the top wall and bottom wall due to the buoyancy. Bulk flow acceleration cannot be negligible in the high heat flux region, which leads to heat transfer deterioration. A new heat transfer correlation is proposed, in which the buoyancy parameter and bulk flow acceleration have been taken into account. The new correlation and six classic correlations for sCO2 are examined in horizontal tubes. The comparison indicates that the new correlation has a better performance for sCO2 flowing through a horizontal heating tube under natural circulation conditions. For example, 94.9% of the calculated results using the new heat transfer correlation were within ±30% of the experimental results while only 87.9% of that using the Jackson correlation (the best of the six) were within the same error bands.

마이크로 유체 원심분리기의 입구 조건과 챔버 크기에 따른 회전 유동 성능 평가 (Performance Evaluation of Rotational Flow of a 2×2 Microfluidic Centrifuge with varying Inlet Conditions and Chamber Sizes)

  • 전형진;권봉현;김대일;김형훈;고정상
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.43-48
    • /
    • 2014
  • This paper describes the measurement of performance evaluation of rotational flow varying chamber size and Reynolds number. Through the experimental visualization of the flow rotation, the number and position of flow rotation in the $2{\times}2$ microfluidic centrifuge were examined. At a chamber width of 250${\mu}m$, single flow rotation was obtained over at a Reynolds number of 300, while at a chamber width of 500 ${\mu}m$, single flow rotation did not appear. For performance evaluation, the intensity in microchamber was measured during 20 sec. At a chamber width of 250 ${\mu}m$, performance of rotational flow increased as Reynolds number increased. However, the variation of intensity in microchamber remained unchanged at a chamber width of 500 ${\mu}m$. The numerical analysis showed that the threshold centrifugal acceleration to obtain rotational flow for ejected particles was 200g.

급가감속 운전에 따른 듀얼 모노리스형 촉매변환기 내의 유동 균일도와 압력 강하에 관한 수치적 연구 (An Numerical Study on the Flow Uniformity and Pressure Drop in Dual Monolith Catalytic Converter during the Rapid Acceleration/Deceleration Driving)

  • 김영득;정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.63-71
    • /
    • 2007
  • The conversion efficiency, durability and pressure drop of the automotive exhaust catalysts are dependent on the flow distribution within the substrate. Conventional porous medium approaches assuming monolith resistance based on the one-dimensional laminar flow for simulating the flow through the automotive exhaust catalysts over-predict the flow uniformity in the monolith. In this study, additional pressure loss is also considered by accounting for entrance effects due to the oblique flow incident on the front face of monolith as a consequence of flow separation and recirculation within the diffuser. The incorporation of an additional pressure loss improves the predictions for the maximum flow velocity within the substrate. An numerical study has also been conducted for the three-dimensional unsteady incompressible non-reacting flow inside various dual-monolith catalytic converters for the rapid acceleration/deceleration driving.

평판 경계층 확산화염에서의 국부적 가속현상에 관한 실험적 연구 (An experimental study on the local velocity acceleration in a flat plate boundary layer diffusion flame)

  • 심성훈;하지수;신현동
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.847-864
    • /
    • 1988
  • 본 연구에서는 연료분출에 박리가 있는 경우와 없는 경우 각각에 대하여 화염 대 근처의 국부가속 현상이 박리에 의하여 어떻게 영향을 받는가를 실험적으로 규명하 고, 나아가서 종래에 행해져 왔던 관련 연구 결과를 재검토할려고 한다.

극저온 자연순환회로의 가속 및 저중력 구간 유량 분석 (Analysis of the Flow Rate for a Natural Cryogenic Circulation Loop during Acceleration and Low-gravity Section)

  • 백승환;정영석;조기주
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.43-52
    • /
    • 2019
  • 극저온 유체를 사용하는 발사체는 극저온 유체의 자연순환회로를 이용하여 발사체의 엔진 입구를 냉각한다. 자연순환회로의 질량유량은 순환시스템을 구성하는 배관의 길이 및 직경과 시스템으로 들어오는 열유입에 의하여 결정된다. 극저온 유체의 자연순환회로의 순환 검증 및 질량유량 측정을 위하여 실험을 진행하였으며, 이론적 계산 결과와 비교하였다. 비교 결과 12%의 오차가 있음을 확인하였다. 이 결과를 바탕으로 발사체 상단에서 저중력 구간 및 가속 구간에서의 자연순환 질량유량을 예측한 내용을 포함한다. 가속구간에서는 산화제탱크가 100 kPa 내외로 유지하는 것이 자연순환유량 증가에 이로웠으며, 저중력구간에서는 중력가속도의 크기에 따른 최적 압력으로 조절해야 자연순환유량의 최고값을 유지할 수 있었다.

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • 제4권2호
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

유체의 물성치변화를 고려한 수직원형관내 고온기체유동에 관한 직접수치모사 (Direct Numerical Simulation of Strongly-Heated Internal Gas Flows with Large Variations of Fluid Properties)

  • 배중헌;유정열;최해천;유종우
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1289-1301
    • /
    • 2004
  • Direct numerical simulation (DNS) of strongly-heated air flows moving upward in a vertical tube has been conducted to investigate the effect of gas property variations on turbulence modification. Three heating conditions(q$_1$$^{+}$=0.0045, 0.0035 and 0.0018) are selected to reflect the experiment of Shehata and McEligot (1998) at the inlet bulk Reynolds numbers of 4300 and 6000. At these conditions, the flow inside the heated tube remains turbululent or undergoes a transition to subturbulent or laminarizing flow. Consequently, a significant impairment of heat transfer occurs due to the reduction of flow turbulence. The predictions of integral parameters and mean profiles such as velocity and temperature distributions are in excellent agreement with the experiment. The computed turbulence data indicate that a reduction of flow turbulence occurs mainly due to strong flow acceleration effects for strongly-heated internal gas flows. Thus, buoyancy influences are secondary but not negligible especially for turbulent flow at low heating condition. Digital flow visualization also shows that vortical structures rapidly decay as the heating increases.s.

다양한 벽면 두께를 갖는 원형 노즐에서 분사되는 난류 충돌 및 벽면 제트 유동장 특성 (Characteristics of Turbulent Impinging and Wall Jet Flow for a Circular Nozzle with Various Exit Wall Thickness)

  • 양근영;윤상헌;손동기;최만수
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.751-757
    • /
    • 2001
  • An experimental study of impinging jet-flow structure has been carried out for a fully developed single circular jet impingement cooling on a flat plate, and the effect of the wall thickness at nozzle exit edge is investigated. Impinging jet flow structures have been measured by Laser-Doppler Velocimeter to interpret the heat transfer results presented previously by Yoon et al.(sup)(10) The peaks of heat transfer rate are observed near the nozzle edge owing to the radial acceleration of jet flow when the nozzle locates close to the impingement plate. The growth of the velocity fluctuations in the wall jet flow is induced by the vortices which originate in the jet shear layer, and consequently the radial distribution of local Nusselt numbers has a secondary peak at the certain radial position. As a wall of circular pipe nozzle becomes thicker for small nozzle-to-target distance, the entrainment can be inhibited, consequently, the acceleration of wall jet flow is reduced and the heat transfer rate decreases.