• Title/Summary/Keyword: Floor plan

Search Result 641, Processing Time 0.026 seconds

A study on the high-level house floor plan used the old drafts owned by the head family of Ongye in Andong (안동(安東) 온계종택(溫溪宗宅) 소장(所藏) 가도(家圖)를 통한 반가(班家) 평면형식 고찰)

  • Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.17 no.1
    • /
    • pp.85-102
    • /
    • 2008
  • As a result of analyzing the floor plan shown in the three drafts, there were a great deal of differences in composing the space of the inner main hall. The inner room facing to the east with the arrangement crossing the inner floor at right angles in the 'Baekdangguje Draft' faces to the south in the east or west in front of the main house thereafter. This represents that it reflects the intent of the owner of the architecture emphasizing the size increase and ceremonies of the main house in the 'ㅁ shape', which has changed to the directions of easily accommodating the Confucian ceremonial activities in the floor plan of the inner house as the size of the main house was gradually increasing from 24 sections to 30 or 38 sections. The expansion in the size of main house further divided the functions of floor into one for daily life and the other for ceremonies as well. In other words, the 30 Sections in Yijeong Draft as being the first planned draft for reconstruction had a hall for memorial services in the main hall of the inner house, whereas the 'Draft with 38 Sections' as being the second planned draft for reconstruction was planning a room with a floor (two sections of Bangdang) for memorial purpose in the back of the inner main hall. The variations in the guest house (or space for men) shown in the drafts confirms the establishment of space for men as the size of the main house increases. We can see the change that a large guest house is placed over the south and in the south and east of the main house as the number of main house increases by 30 sections or 38 sections. Especially, a guest house with a wide space in a 'ㄴ shape' is arranged from the south of main house to the east wing in the Draft with 38 Sections. In addition, the backward sections are advanced in the front and back of guest house in the drafts with 30 and 38 sections, while a back floor or a back floor connecting to the back room or sleeping room or inner house is installed in the backward sections.

  • PDF

The Characteristics in the Planning Process of Co-housing: Modification of Plans by Residents' Participation - Case of Co-housing Built by a Coordination Company in Seongmisan Village - (거주자참여 코하우징의 평면조정에서 나타난 계획과정의 특성 - 코디네이터회사에 의한 성미산마을 코하우징 사례연구 -)

  • Park, Kyoung-Ok;Lee, Sang-Un;Ryu, Hyun-Soo
    • Journal of the Korean housing association
    • /
    • v.24 no.4
    • /
    • pp.61-73
    • /
    • 2013
  • The purpose of this study is to provide information needed to the construction of the co-housing in the urban area. This study focused on the characteristics of co-housing in its planning process of private house & common space; 'economy', 'creativity' & 'sociality'. The object of this study is co-housing in 'Seongmi-san Village' in Seoul, which was built by a coordination company with residents' participation. The methods are investigating interview materials, floor plans of 9 households, & common space plans produced in the coordination process from the basic plan of private house & common space to the final plan. The results are as follows. 1) The size and plan of private house differed from each other. The water pipe location differed from each floor, so that there were difficulties in construction. In conclusion, these made no 'economy', but brought high 'creativity'. 2) The 'sociality' would be estimated as high because there were various types of resident participation; resident interviews on the planning, workshops for private housing plan, and workshops for common space.

Comparison of different distributions of viscous damper properties in asymmetric-plan frames

  • Landi, Luca;Molari, Andrea;Diotallevi, Pier Paolo
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.233-248
    • /
    • 2020
  • In this article, one of the procedures to design viscous dampers proposed in literature is applied to 3D asymmetric-plan buildings, considering different distributions for the damping coefficients, which are assumed to be proportional to specific structural or response parameters. The main purpose was to investigate the effectiveness of different vertical and in-plan distributions of the damping coefficients of nonlinear viscous dampers for the seismic retrofit of existing buildings. For comparison purposes, all the distributions were applied utilizing both a simplified and an extended method for the 3D structures, where the simplified method takes into account only the translation in the seismic direction, and the extended method considers the translations along the two orthogonal directions together with the floor rotations. The proposed distributions were then applied to a typical case study involving an asymmetric-plan six-storey RC building. The effectiveness of the different distributions was examined through time-history analyses, assuming nonlinear behaviour for both the viscous dampers and the structural elements. The results of the nonlinear dynamic analyses were examined in terms of maximum and residual inter-storey drifts, peak floor accelerations and maximum damper forces.

A Study on the Preference and Using behavior of Residents According to Plan types of Master Room in Apartment Housing (아파트 부부공간 존 유형에 따른 거주자 사용행태 및 선호도)

  • Choi, Yu-Mi;Kang, Soon-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.350-356
    • /
    • 2008
  • Recently, house market is focusing to consumer because competition between contractors is getting more deeply. So they are suppling various plans and changing space to confront lifestyle of consumers. This study has researched types of master rooms and analyzed the Preferences of users, so offers a basic material of master room zoning plan.

  • PDF

An Analysis of the Planning Characteristics of Elderly Welfare Housing Units and Their Ability to Meet Potential Residents' Needs (노인복지주택 단위주거 평면계획 특성 및 잠재적 거주자 주거요구 분석)

  • Lee, Youn-Jae
    • Journal of the Korean housing association
    • /
    • v.24 no.4
    • /
    • pp.97-107
    • /
    • 2013
  • The purpose of this paper is to investigate the planning characteristics of certain cases of elderly welfare housing (hitherto EWH), and analyze any problems by comparing this against the actual needs of potential residents. To this end, 38 distinct housing plans from twelve EWH built after 2005 were examined, and a survey on housing needs was taken by 198 people between 48 and 62 years of age. The results are as follows: Firstly, the most common size found among the 10 cases was 42-66 $m^2$, however larger sizes are becoming more frequent. The most popular response on the survey was one favoring smaller housing options. Secondly, the most common floor plan examined consisted of 1 bedroom + LDK and 2 bedroom + LDK. Likewise, the survey reflected that 1 or 2 bedroom housing was preferred. Thirdly, a floor plan composed of a smaller bedroom and LDK is commonly found in smaller floor plans of EWH. The survey reflected potential residents preferred this same style of floor plan, with a smaller bedroom and LDK set up. However, lower-income participants preferred a single, larger bedroom which also can serve as a living space, to go along with a kitchen/dining room (DK). Fourthly, 2 bedroom housing typically included a single bathroom, however the survey indicated that participants preferred a second bathroom to go along with a second bedroom. Consequently, the planning of elderly welfare housing is to a large extent meeting the demands of its potential residents, however house size and the planning of bathrooms have yet to meet these demands, especially with potential lower-income residents when it comes to housing size and space composition.

A Study on the Spatial Characteristics of Elderly Care Facilities in Gyeongnam- Province (경남지역 노인요양시설의 공간 특성에 관한 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.21-29
    • /
    • 2021
  • The purpose of this study is to present the basic direction of the desirable spatial plan for elderly care facilities by analyzing the spatial characteristics of elderly care facilities in gyeongnam-province. As a research method, 189 elderly care facilities in gyeongnam-province were investigated for location conditions, site area, floor area, total floor area, and space composition. In addition, the area of each specific space was analyzed for two elderly care facilities with a typical floor plan. The results of the survey and analysis are as follows. First, the average number of people in the facility was 53.8, and the number of people in the facility needs to be planned to be medium or less so that they can live in a more comfortable environment in the future. Second, in the location type, it was found that many facilities were distributed in the order of suburban and rural type, urban type, mountain type, and waterfront type. In addition, in terms of facility space composition, the proportion of detached facilities was 50.8%. Complex facilities require a reasonable plan in consideration of the location type and other functional facility characteristics. Third, the average total floor area per person of elderly care facilities was 27.57m2. There is a limit to constructing a unique nursing space. In the composition of bedrooms, quadruple rooms account for 67.4%, but it is necessary to expand the proportion of bedrooms that can be used by fewer people.

Simulation for Shop Floor Control

  • Cho, Hyunbo
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1996.05a
    • /
    • pp.15-15
    • /
    • 1996
  • A shop floor control system (SFCS) is the central part of a CIM system used to control the activities of several pieces of manufacturing equipment (e.g., NC machines, robots, conveyors, AGVs, AS/RS). The SFCS receives orders and related process plans, and then performs selecting a specific process routing, allocating resources, scheduling the workpieces, downloading the processing instructions (e.g., RS-274 instructions for NC machines, VAL II programs for robot), monitoring the progress of activities, detecting and recovering from errors, and preparing reports on the status of the manufacturing system. Simulation has been utilized in discovering control policies used for resolving shop floor be control problems such as resource contentions, part dispatching, deadlock. The simulation model must be designed to respond to real-time data coming from a shop floor. However, to rapidly build a realtime simulation model of SFCS cannot be easily accomplished. This talk is to address an automatic program generator of discrete event simulation model for shop floor control from process plans and resource models. The program generator is capable of constructing complete discrete simulation models for multi-product and multi-stage flexible manufacturing systems.

  • PDF

A Study on the Improvement of Average Floor Height Ordinance through Analyzing Landscape Impacts of Average Floor Height System Applied to Apartment Buildings in Residential Areas of Seoul (공동주택 평균층수 적용에 따른 경관영향 분석 및 제도운용 개선방안 연구)

  • Mok, Jeong-Hun;Kim, Sung-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.62-70
    • /
    • 2007
  • The purpose of this research is to suggest an improved method of how to apply and operate an average floor height system to rebuilt or redeveloped apartment buildings in general residential areas of Seoul. This research suggested two research findings by a computer simulation study for analyzing the difference between the average floor height of apartment buildings in experimental sites and the average of floors of buildings near experimental sites. The first finding is that an average floor height system should be applied to apartment buildings with a limitation of maximum height at sites larger than $12,000m^2$ in order to control the difference of the maximum height of buildings between apartment sites and their surroundings. The second finding is that the average floor height system should be operated by an appropriate average floor height ratio at sites greater than $50,000m^2$ in order to harmonize rebuilt or redeveloped apartment buildings with their surroundings.

A Study on the Effectiveness of Floor Area Ratio Incentive System for Long-Life Housing Certification System (사례 분석을 통한 장수명주택의 용적률 인센티브 실효성 검토)

  • Jung, Yoon-Hye;Kang, Ji-Yeon;Kim, Hyung-Geun;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2020
  • The purpose of this study is to investigate the effect of floor area ratio incentive system for Long-life housing certification system by simulation of five recently built apartment complexes. Apartments that are certified as superior in Long-life housing can receive 10% of the floor are incentive in Seoul. However, the difference between base and permitted floor area ratio are in general residential area of class 2 and 3 is not more than 20%. limit of feasible allowance incentive is limited. Even if there is an unrealized permitted floor area ratio, there is no reason to apply the Long-life housing certification system preferentially. Because the items of the floor area ratio incentive provided by the District Unit Plan are various, it shows that the floor space ratio incentive for Long-life housing certification system has little effectiveness. To enhance the feasibility of incentives for the Long-life housing certification system, improvement in the urban planning level, including district unit planning, including the design criteria for apartments in Seoul, is needed.

A Study on Evaluation Method of Floor Noise Reduction and Blocking Performance for Apartment Buildings in Korea (국내 공동주택 건축물 층간소음 저감 방안 및 차단 성능 등급평가법에 관한 고찰)

  • Jung, Kyung-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.3
    • /
    • pp.69-77
    • /
    • 2024
  • The purpose of this study is to present a plan for reducing noise between floors of apartment houses in Korea and to examine the method for evaluating noise blocking performance rating between floors. The definition of floor noise and classification method of floor noise can be described, and floor noise can be distinguished into lightweight impact sound and heavy impact sound. The wall-type structure, which is mainly adopted in domestic apartments, relatively transmits vibration caused by impact sources rather than using columns and beams, so noise problems between floors are relatively higher than systems using columns and beams. Three representative methods for reducing and blocking floor noise are described, and criteria for evaluating the effectiveness of floor noise reduction by each method are described. In addition, the method for noise reduction and blocking grades for each construction method currently applied in Korea was described, and as a result, it was judged that the domestic rating evaluation method was not suitable for the current domestic situation, and a new evaluation method and standard were needed.