• Title/Summary/Keyword: Floor Type

Search Result 937, Processing Time 0.024 seconds

Structural analysis for floor structure of Rolling Stock (철도차량 바닥 구조 해석)

  • Kim, Yong-Tae;Kim, Myeong-Soo;Park, Kyeong-Bong;Park, Jea-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.61-69
    • /
    • 2011
  • The noise and vibration which are occurred by equipment and rail under the train are directly delivered to passenger and effect on comfort. For this reason, Floating floor structure has been applied to Rolling Sotck for minimizing the noise and vibration. And in respect of Floating floor, the strength is an important design element. Because the train has many heavy equipments and accommodates lots of passenger. At the early design stage of Floating floor, different joint type and thickness of plywood, etc. were applied and some problem happened. To solve the problems and apply to the future projects, the standard model of Floating floor structure was required. To find optimum design and standard model for Floating floor structure of Rolling Stock, the applied Floating floor models were analysed by CAE (computer-aided engineering).

  • PDF

Development of an Eddy Current Type Magnetic Floor Hinge

  • Lee, Kapjin;Kim, Chulsoo;Park, Kyihwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.118.4-118
    • /
    • 2002
  • $\textbullet$ Magnetic floor hinge $\textbullet$ Recovering torque $\textbullet$ Eddy Currents $\textbullet$ Magnetic damper $\textbullet$ Optimal design $\textbullet$ Cost optimization

  • PDF

A Study on the Spatial Characteristics of Elderly Care Facilities in Gyeongnam- Province (경남지역 노인요양시설의 공간 특성에 관한 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.21-29
    • /
    • 2021
  • The purpose of this study is to present the basic direction of the desirable spatial plan for elderly care facilities by analyzing the spatial characteristics of elderly care facilities in gyeongnam-province. As a research method, 189 elderly care facilities in gyeongnam-province were investigated for location conditions, site area, floor area, total floor area, and space composition. In addition, the area of each specific space was analyzed for two elderly care facilities with a typical floor plan. The results of the survey and analysis are as follows. First, the average number of people in the facility was 53.8, and the number of people in the facility needs to be planned to be medium or less so that they can live in a more comfortable environment in the future. Second, in the location type, it was found that many facilities were distributed in the order of suburban and rural type, urban type, mountain type, and waterfront type. In addition, in terms of facility space composition, the proportion of detached facilities was 50.8%. Complex facilities require a reasonable plan in consideration of the location type and other functional facility characteristics. Third, the average total floor area per person of elderly care facilities was 27.57m2. There is a limit to constructing a unique nursing space. In the composition of bedrooms, quadruple rooms account for 67.4%, but it is necessary to expand the proportion of bedrooms that can be used by fewer people.

Research on the HSE Application with Smart Device and Biometrics (스마트디바이스를 이용한 HSE 적용에 관한 연구)

  • Woo, Jong Hun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.157-168
    • /
    • 2014
  • In this paper, HSE (Health and Safety Environments) research with smart device and biometrics is conducted for the worker's HSE enhancement in the manufacturing shop floor. Today, various kinds of smart devices are popularized extensively. In addition, the wearable type devices are being introduced such as google glass very recently. Smart device of werable type is exptected to bring great opportunity out in terms of HSE functionality. Smart devices of phone or tablet type are being used for on-line work between control center and manufacturing shop floor by virtue of wireless communication. However, those devices are not appropriate for detecting of worker's physical senses such as temperature and pulse. In this paper, we developed a glass type smart device and required funictions for HSE enhancement with the investigation of biometrics technology. Also, required sensors are investigated for the detecting of temperature, pulse and noxious gasses. Smart device of glass type has advantages in that most senses of personnel are gathered around faces, and also it's possible to detect neutral axis of body because the wearing location is fixed. We expect that the proposing HSE product of glass type smart device could contribute the enhancement of the HSE of manufacturing shop floor.

An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea (국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析))

  • Byun, Gye-Sung
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building (중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak;Huh, Mean-Haeng;Hong, Kun-Ho;Ha, Jae-Hoon;Nam, Young-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.453-454
    • /
    • 2009
  • In this dissertation, experimental program was carried out to study the hysteretic behavior of the reinforced different floor type interior beam-column joint repeated cyclic loads under seismic actions. The test results was as follow. The reinforced interior beam-column joint, designed by the different floor type, was increased energy dissipation capacity and maximum load carrying capacity according to the increase of different floor in comparison to standard specimen. And it was also dissimilar to failure mode adjacent to joint region. energy dissipation capacity of each specimen, designed by the different floor type, was increased 1.1${\sim}$1.35 times in comparison to standard specimen.

  • PDF

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

Spatial Transfigurations by Floor Plan Type of Elderly Center in Apartment Complex (아파트 단지 내 경로당의 평면유형에 따른 공간변용)

  • Yang, Se-Hwa;Ryu, Hyun-Joo
    • Journal of Families and Better Life
    • /
    • v.31 no.1
    • /
    • pp.29-37
    • /
    • 2013
  • The purposes of the study were to try configuring categorization of floor plans of elderly centers located in apartment complexes and to find out the spatial transfigurations regarding floor plan types. The data for the analysis of the study were collected from 56 elderly centers of apartment complexes in Ulsan by observations and interviews from July 3 through 13, 2012. The results are as follows. Firstly, the floor plans of the elderly centers were categorized into six types, which were 2R+L+K, 2R+LK, 1R+L+K/1R+LK, 1RL+K, 1RLK, and 2R+K/1R+K(no living room). Secondly, there were no salient differences among the plan types for the characteristics of physical environment of the centers. The types of 2R+L+K were relatively big in size and two thirds of the centers had gender-segregated rooms. Lastly, spatial transfigurations was found in sixty-percent of the centers, which included change of spatial arrangement, functional change, and functional addition. Interestingly, the more the spaces were segregated, the more the spatial transfigurations were performed in the way for the integration of functions of the rooms.

Heavy-weight Impact Sound Characteristics of Floor Structure of a Small-Sized Wall-Slab Apartment Building having Joist Slab (장선슬래브를 갖는 소형평형 벽식구조 아파트 바닥구조의 중량충격음 특성)

  • Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.8-15
    • /
    • 2020
  • In the present paper, as a way of reducing heavyweight impact sounds, in particular, among floor impact sounds which have come to the forefront as a social issue recently, a floor joist slab is proposed that is expected to bring an effect of reducing heavyweight impact sounds through a shift in the natural frequency by installing a floor joist on a flat-type slab to increase the rigidity of the floor slab, differently from the existing method that increases the thickness of floor slab, and the heavyweight impact sound characteristics depending on the floor joist height and interval are interpretively analyzed. As a result of the analysis, though a trend is shown where the sound pressure level decreases as the slab thickness of floor joist increases, and as no difference is shown when thickness is above a certain value, it is thought that there is a threshold for the effect of an increase in floor thickness on blockage of heavyweight impact sounds. Also, as an increase in floor rigidity resulting from an increase in the floor joist height and a decrease in the interval does not lead to a consistent increase in the performance of blocking heavyweight impact sounds, it is thought that a different floor joist height and interval should be applied to each type of house to expect optimum performance of blocking heavyweight impact sounds, and an increase of 100mm in the floor joist height or a decrease of about 100mm in the interval is expected to bring an effect of reducing heavyweight impact sounds by about 1dB to 2dB.