• Title/Summary/Keyword: Floor Temperature

Search Result 471, Processing Time 0.024 seconds

Preparation of Styrene-Ethyl acylate Core-shell Structured Detection Materials for aMeasurement of the Wall Contamination by Emulsion Polymerization

  • Hwang, Ho-Sang;Seo, Bum-Kyoung;Lee, Dong-Gyu;Lee, Kune-Woo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.84-85
    • /
    • 2009
  • New approaches for detecting, preventing and remedying environmental damage are important for protection of the environment. Procedures must be developed and implemented to reduce the amount of waste produced in chemical processes, to detect the presence and/or concentration of contaminants and decontaminate fouled environments. Contamination can be classified into three general types: airborne, surface and structural. The most dangerous type is airborne contamination, because of the opportunity for inhalation and ingestion. The second most dangerous type is surface contamination. Surface contamination can be transferred to workers by casual contact and if disturbed can easily be made airborne. The decontamination of the surface in the nuclear facilities has been widely studied with particular emphasis on small and large surfaces. The amount of wastes being produced during decommissioning of nuclear facilities is much higher than the total wastes cumulated during operation. And, the process of decommissioning has a strong possibility of personal's exposure and emission to environment of the radioactive contaminants, requiring through monitoring and estimation of radiation and radioactivity. So, it is important to monitor the radioactive contamination level of the nuclear facilities for the determination of the decontamination method, the establishment of the decommissioning planning, and the worker's safety. But it is very difficult to measure the surface contamination of the floor and wall in the highly contaminated facilities. In this study, the poly(styrene-ethyl acrylate) [poly(St-EA)] core-shell composite polymer for measurement of the radioactive contamination was synthesized by the method of emulsion polymerization. The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS)as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SOS) as an emulsifier using ammonium persulfate (APS) as an initiator. The polymer was made by impregnating organic scintillators, 2,5-diphenyloxazole (PPO) and 1,4-bis[5-phenyl-2-oxazol]benzene (POPOP). Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by IT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Radiation pollution level the detection about under using examined the beta rays. The morphology of the poly(St-EA) composite polymer synthesized by the method of emulsion polymerization was a core-shell structure, as shown in Fig. 1. Core-shell materials consist of a core structural domain covered by a shell domain. Clearly, the entire surface of PS core was covered by PEA. The inner region was a PS core and the outer region was a PEA shell. The particle size distribution showed similar in the range 350-360 nm.

  • PDF

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Analysis of Current Situation for Environmental Facilities and Disinfection in Hanwoo Farms (한우농가의 환경시설관리 및 방역실태 분석)

  • Kim, Gye-Woong;Kim, Kon-Joong
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2011
  • This survey was conducted to investigate the current situation of ground condition of barn, moisture condition, feeding facilities, disinfection tool, etc. The data from a total of 305 farms were collected and analysed for establishment of managemental target in Hanwoo farm. The ground condition of barn was evaluated as a result of "moderate level" (46.4%). The moisture removal on the ground was conducted with the aid of electric fan (36.4%). The natural wind and sunlight should be used gradually for economic effect in farm. The exchange of floor straw was mostly conducted to remove the bad smell of barn (33.7%). 37.0% of farms had no the electric fan in internal barn, this instrument must be installed for control of body temperature and internal moisture in the future. Most of feeding facilities were operated by hand(88.2%). Modern farms should be installed with automatic feeding system. Farmer's skill of management was evaluated as a "2.80" of 5 points. Accordingly, farmers should be trained with high level of technical competitive skill. In conclusion, Hanwoo farms should be promoted and improved for enhancement of income through introduction to scientifically modern feeding skill.

Study on Seombody Drying (섬바디의 건조에 관한 연구)

  • Park, Kyung-Kyu;Chung, Chang-Joo
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-55
    • /
    • 1976
  • An experimental work was conducted to develop an optimum operating system of various hay drying systems ; sun-drying with long hay, sun-drying after chopping, sun-drying after crushing, heated air drying after chopping using batch-type dryer and heated air drying after crushing using tunnel-type dryer. Seombody having 60 cm long and initial moisture content of approximately 79 % in wet basis was used for the experiment. The criteria selected for determining the optimum operating condition were the drying performance rate, the production cost and quality of dried matter of each drying systems. The result of this study are summarized as follows : 1. Drying characteristics of leaves of long stem hay, chopped seombody and crushed one were obtained by maintaining the oven temperature at 70 degrees centigrade. The required drying times for various samples to approximately 15% moisture content in wet basis were about 50 min .for leaves ; 160 min. for crushed hay ; 250 min. for chopped hay ; 340min. for ling hay and more than 360 min .for stems. The drying time of crushed hay was required about 50 % of that for the uncrushed long hay. Such a significant difference of drying of time between the leaf and long stem may indicate that an effective drying of seombody may not be achieved unless any kind of special process treatment for the whole hay is undertaken. 2. In each individual drying system, the following conclusions were drawn: a. After 8 days sun-drying on concrete floor under good days with average tempe?rature at $256{\circ}C$ and relative humidity at 55% at 2 P.M., the moisture content of long hay was still above 25 5'~ and the leaf loss during drying caused by wind and rough handling was more than 50 ~G. b. It was possible to dry the chopped seombody by sun-drying down to about 10 % moisture content within 5 days, however, a stock of heat and discolouration phenomena were observed during the drying, which may be due to the increased deposit-density by chopping, resulting in lowering the quality of the dried product. c. Sun-drying for the crushed material by hay-conditioner was required about 4 days to reduce the moisture content to about 10 %, keeping the quality of dried product at good grade. o. The optimum deposit-depth of the chopped seombody in the batch-type dryer used was about 28cm with about 42kg/hr of drying performance rate. However, it was necessary to overturn the materials between the upper and lower layers in order to obtain a good quality of dried product. d. The drying performance rate by the tunnel-type drier was highest among those of drying systems tested, giving the rate of approximately 400kg/day. 3. On reviewing the individual drying system for seombody, it was possible to draw conclusion that the best system was tunnel drying with the crushed seombody as far as the performance rate was concerned. However, the methods gives the highest operational cost. The system for the lowest operational cost with good quality of dried product was the sun-drying with the crushed material. Accordingly, it may be recommended that the system of sun-drying for the crushed seombody may be the most feasible system presently applicable to farm-level operation.

Study on Seombody Drying (섬바디의 건조에 관한 연구)

  • 박경규
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.56-63
    • /
    • 1976
  • An experimental work was conducted to develop an optimum operating system of various hay drying systems ; sun-drying with long hay, sun-drying after chopping, sun-drying after crushing, heated air drying after chopping using batch-type dryer and heated air drying after crushing using tunnel-type dryer. Seombody having 60 cm long and initial moisture content of approximately 79 % in wet basis was used for the experiment. The criteria selected for determining the optimum operating condition were the drying performance rate, the production cost and quality of dried matter of each drying systems. The result of this study are summarized as follows : 1. Drying characteristics of leaves of long stem hay, chopped seombody and crushed one were obtained by maintaining the oven temperature at 70 degrees centigrade. The required drying times for various samples to approximately 15% moisture content in wet basis were about 50 min .for leaves ; 160 min. for crushed hay ; 250 min. for chopped hay ; 340min. for ling hay and more than 360 min .for stems. The drying time of crushed hay was required about 50 % of that for the uncrushed long hay. Such a significant difference of drying of time between the leaf and long stem may indicate that an effective drying of seombody may not be achieved unless any kind of special process treatment for the whole hay is undertaken. 2. In each individual drying system, the following conclusions were drawn: a. After 8 days sun-drying on concrete floor under good days with average tempe\ulcornerrature at $256{\circ}C$ and relative humidity at 55% at 2 P.M., the moisture content of long hay was still above 25 5'~ and the leaf loss during drying caused by wind and rough handling was more than 50 ~G. b. It was possible to dry the chopped seombody by sun-drying down to about 10 % moisture content within 5 days, however, a stock of heat and discolouration phenomena were observed during the drying, which may be due to the increased deposit-density by chopping, resulting in lowering the quality of the dried product. c. Sun-drying for the crushed material by hay-conditioner was required about 4 days to reduce the moisture content to about 10 %, keeping the quality of dried product at good grade. o. The optimum deposit-depth of the chopped seombody in the batch-type dryer used was about 28cm with about 42kg/hr of drying performance rate. However, it was necessary to overturn the materials between the upper and lower layers in order to obtain a good quality of dried product. d. The drying performance rate by the tunnel-type drier was highest among those of drying systems tested, giving the rate of approximately 400kg/day. 3. On reviewing the individual drying system for seombody, it was possible to draw conclusion that the best system was tunnel drying with the crushed seombody as far as the performance rate was concerned. However, the methods gives the highest operational cost. The system for the lowest operational cost with good quality of dried product was the sun-drying with the crushed material. Accordingly, it may be recommended that the system of sun-drying for the crushed seombody may be the most feasible system presently applicable to farm-level operation.

  • PDF

A Study on the Surface-Radiation Heat Transfer Characteristics in an Open Cavity with a Heat Source (발열체가 존재하는 개방된 정사각형공간에서 표면복사 열전달 특성에 관한 연구)

  • Nam, Pyoung-Woo;Park, Myoung-Sig;Park, Chan-Woo
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.70-83
    • /
    • 1992
  • The interaction between the surface radiation and the mixed convection transport from an isolated thermal source, with a uniform surface heat flux input and located in a rectangular enclosure, is stuied numerically. The enclosure simulates a practical system such an air cooled electric device, where an air-stream flows through the openings on the two vertical walls. The heat source represents an electric component located in such an enclosure. The size of this cavity is $0.1[m]{\times}0.1[m]$. The inlet velocity is assumed as 0.07[m/s] and the inlet temperature is maintained as $27^{\circ}C$. The inflow is kept at a fixed position. Laminar, two dimensional flow is assumed, and the problem lies in the mixed convection regime, governed by buoyancy force and surface readiation. The significant variables include the location of the out-flow opening, of the heat source and the wall emissivity. The basic nature of the resulting interaction betwwn the externally induced air stream and the buoyancy-driven flow generated by the source is investigated. As a result, the best location of the heat source to make the active heat transfer is 0.075[m] from the left wall on the floor. The trends observed are also discussed in terms of heat removal from practical systems such as electric circuitry.

  • PDF

The Study on the Pressure-Sensitive Adhesion Property of Waste FKM Powder and SBS Modified Asphalt (폐불소고무 분말과 SBS로 개질된 아스팔트의 점착 특성에 관한 연구)

  • Chung, Kyung-Ho;Kang, Min-Kyu;Han, Kyung-A
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.282-289
    • /
    • 2009
  • The pressure-sensitive adhesive(PSA) tapes are widely used as floor-sealing material in Korean constructive industry. However, the general PSA tapes can not seal the apertures completely. This is one of main reasons to cause imperfect finishing. In order to solve the problems, the asphalts were modified by FKM powder and SBS in this study. The physical properties of modified asphalts were examined by measuring the softening point, viscosity, tensile strength and adhesion strength of FKM and SBS modified asphalt. The softening point of SBS modified asphalt was increased greatly due to the formation of network structure in asphalt. Also, the change of adhesion strength of SBS modified asphalt with temperature was not so great comparing to those of pure asphalt and FKM modified asphalt. The best results of pressure-sensitive adhesion could be obtained by the SBS(linear) modified asphalt containing 6 wt.% of linear type SBS.

Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials (건축용 바닥재로부터의 휘발성유기화합물 방출특성)

  • Yun, Joong-Seop;Lee, Myong-Hwa;Eom, Seok-Won;Kim, Min-Young;Kim, Jong-Ho;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.973-978
    • /
    • 2010
  • The emission of volatile organic compounds (VOCs) from building materials is one of great concerns due to maintain airtight condition of a building to reduce energy consumption, and it causes the deterioration of indoor air quality. Therefore, the emission characterization of VOCs from building materials is necessary to improve indoor air quality. Emission characteristics of VOCs from a plywood flooring that is one of the most commonly used materials in an under-heating system, and from an adhesive that is generally used to stick a plywood flooring to a concrete floor were investigated using an emission chamber test in this study. It was found that the VOCs emission factor was dependent upon and proportional to indoor temperature, and the emission characteristics were closely related to the existing places and conditions of VOCs sources inside the building materials. Maximum emission factors of hexane and toluene from building materials were generally observed at the beginning, however, only that of toluene from a plywood flooring was shown after 6 hours from the beginning. It could be considered that the existing place and condition of toluene source inside a plywood flooring could influence on the VOCs emission. From this study, bake-out time more than 72 hours could be recommended before moving in to avoid the exposure to high concentration of VOCs emitted from an under-heating system.

Preference of Stroke Patients for Bathroom Environment in Residential Space (뇌졸중 환자가 선호하는 주거공간의 욕실 환경 특성)

  • Lee, Kyoung-Min;Kim, Yu-Seon;Yoon, Su-Jeong;Hong, Ki-Hoon;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.31-40
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preference of bathroom environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Results : First, the subjects demand for improvement that non-slip tile and safety handle on bathtub. Second, they preferred the sliding door, sliding door handle, shower booth of convenient facility, non-slip tile, built-in cabinet, L-shaped safety handle, natural ventilating window, floor heating, easier bathtub to enter, bathtub with handle, tilted sink, water temperature index, toilet with safety handle, and bath chair. Conclusion : This study would contribute to bathroom environment for safety and ease in use.

  • PDF

A study on the effects of skylight in commercial underground space - with focus on the employees of underground streets in Japan (지하상업공간에서 천창의 효과에 대한 연구 - 일본 지하가 근무자를 중심으로)

  • Lee, Gahng-Ju
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.535-543
    • /
    • 2019
  • This study examined the empirical meaning of skylight in underground space, and for this purpose, 29 questions were drawn, consisting of technical performance, functional performance, and behavioral performance. In addition, under the assumption that the meaning of the skylight will be clearly revealed through the comparison between the underground streets with and without the skylight, three underground streets with the skylight and three underground streets without the skylight of Japan were selected as the subjects of the study. Based on the results of the survey, descriptive statistical analysis and frequency analysis were conducted, and an independent sample T-test was conducted for each analysis, and correlation analysis was conducted to derive improvement priority. As a result of the analysis, it was found that skylight had a certain effect on the sense of time and imageability inside the underground commercial space. In addition, it was analyzed that skylight exerted important function in the qualitative aspect of underground commercial space. Lastly, the improvement rankings for three underground streets without skylight were derived in the order of sign/guide map, space diversity, maintenance, rest space, and floor design.The improvement rankings for three underground streets with skylight were drawn in order of resting space, diversity of space, temperature and humidity, air, and maintenance.