• 제목/요약/키워드: Floor Impact noise

검색결과 334건 처리시간 0.029초

표준바닥충격원의 ACF/IACF 및 Zwicker 파라메타 분석 (ACF/IACF and Zwicker Parameters Analysis on Floor Impact Noise)

  • 전진용;정정호;;조문재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.945-950
    • /
    • 2001
  • Floor impact noise has been evaluated by investigating the temporal and spectral characteristics of the noise. The noises generated by different impactors were analyzed to find out whether there is any correlation with the factors of ACF /IACF (Autocorrelation Function/Inter-aural Cross-correlation Function) [1] and Zwicker parameters [2]. Experiments were undertaken to compare the objective and subjective parameters of the floor impact noises generated by a bang/tapping machine, a rubber ball [3], and a walker. As a result, it was found that $\phi$ (0) and IACC extracted from ACF/IACF, and Loudness, Unbiased Annoyance from Zwicker parameters showed high correlation with subjective evaluations of loudness concerning floor impact noises. In addition, it was revealed that jumping is similar to the ball.

  • PDF

바닥마감재가 경량충격음 저감량 평가에 미치는 영향 (A Study on the Reduction of the Lightweight Impact Sound Level by Floor Coverings)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.137-142
    • /
    • 2004
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by floor coverings. The characteristics on the reduction of the lightweight impact sound level by floor coverings is as follows. The insulation level attained by floor coverings tends to be smaller in actual buildings than in public laboratories. The reduction of the impact sound level to the tape is similar to the method of adhesives. For this reason, the reduction of impact sound level by floor coverings in public laboratories can be utilized to tape. And the reduction of impact sound level by floor coverings is not influenced by the size of specimen except the specific frequency.

  • PDF

청감실험에 의한 공동주택 바닥충격음의 평가등급 설정 (Rating Floor Impact Noise in Apartment Buildings Through Subjective Evaluation Tests)

  • 전진용;류종관
    • 한국음향학회지
    • /
    • 제22권2호
    • /
    • pp.88-95
    • /
    • 2003
  • 본 논문에서는 바닥충격음의 감성적 상하한치를 기준으로 바닥충격음의 감성적 평가등급을 설정하기 위하여 바닥충격음 레벨에 따른 피험자의 주관적 반응을 현장 청감실험을 통하여 조사하였다. 표준 바닥충격원인 중량, 경량 충격음과 현재 일본에서 신 중량충격원으로 제안되고 있는 고무공충격음, 그리고 실제 충격음 (Jumping)을 대상으로 청감실험을 실시하였으며 청감실험에 사용된 주관적 반응의 평가척도로는 일본 건축학회에서 활용되고 있는 3개의 평가척도와 소음평가어휘를 활용한 평가척도를 사용하였다. 청감실험 결과, 바닥충격음 레벨에 따른 주관적 반응의 관계는 1차 회귀식으로 나타났으며, 감성적 하한치가 중량충격음의 경우 역A특성 가중 바닥충격음 레벨 (L/sub i, Fmax, AW/)이 46㏈, 경량충격음의 경우 역A특성 가중 규준화 바닥충격음 레벨 (L'/sub n, AW/)이 56㏈로 나타났다. 최종적으로 청감실험 결과에서 도출된 감성적 하한치의 기준으로 총 3등급의 평가등급이 설정되었다.

모형실험실에서 바닥충격음 완충재의 발포율 및 바닥마감재의 변화에 따른 충격음 차단성능에 대한 실험적 연구 (Experimental Study of Floor Impact Sound Insulation by the Finishing Materials and Porous Ratio of Insulations of Floor Structure in Mock-up Test Room)

  • 김태희;오진균;신일섭;조창근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.756-759
    • /
    • 2003
  • It is increasing the interest on the comfortable dwelling environment and the efforts to solve the problem of the floor impact noise in apartment houses have been realized, as a result numerous products have been made. The purpose of this study is to investigate the sound insulation performances according to foaming rate of floor impact noise insulators and flooring coverings in Mock-up Test Room. The test results of impact insulation performance for each floor impact noise insulators is that double structure of insulator is excel than one in low-middle frequency band and as foaming rate go up, the sound insulation performance is improved.

  • PDF

리모델링 건축물의 바닥슬래브 사용성 및 바닥충격음 성능개선 (Improvement In the Serviceability of Floor Slab of Remodeled Building and the Performance of Floor Impact Noise)

  • 이병권;배상환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1243-1246
    • /
    • 2006
  • As remodeling market is growing and peoples' concern on health and well-being is getting high, there is a need to apply environmentally friendly approach to remodeling an apartment houses. But, in point of the impact noise concerned, the thickness of the concrete slab and the limited ceiling height of the remodelling houses are the main constraints to improve the impact noise performance. In order to investigate the effect of the impact noise isolation as structural treatments for the structural elements, heavy-weight impact noise and tapping noise were measured in an remodeling building. As a result, structural strengthening method by H-beam was successful to enhance the impact noise level at about 3 or 4 class by the sound classification system.

  • PDF

감쇠재 사용에 따른 중량충격음의 소음 및 진동특성 (Noise and Vibration Characteristics of Heavy-weight floor impact by Using Damping Materials)

  • 전진용;정영;송희수;김민배;이영제
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.97-102
    • /
    • 2004
  • The Characteristics of noise and vibration by heavy-weight floor impact sound was studied. Resonance frequency increased a little in structures that use damping material in living room and bedroom, and acceleration waves length that respond became short, and displayed aspect that oscillation level decreases. Result that measure sound pressure level, structure that compare and applies damping materials with structure that apply the resilient materials from 63Hz lower part that impact energy is concentrated in energy spectrum of heavy-weight floor impact sound displayed result that sound pressure, level decreases remarkably. Therefore, according to use of damping materials, confirmed reduction effect of heavy-weight floor impact sound.

  • PDF

도로변 공동주택의 층별 소음보정계수 산정에 관한 연구 (A study on the Calculation of Noise Correction Coefficient on each floor for the estimation on the roadside traffic noise around the Apartment Building)

  • 박영민;이지왕;고정용
    • 환경영향평가
    • /
    • 제14권1호
    • /
    • pp.25-36
    • /
    • 2005
  • Actually, prediction formula of road traffic noise for EIA(Environmental Impact Assessment) has been used that proposed by National Institute of Environmental Research in 1999. The prediction formula, however, was calculated predicted noise level according to noise level producing on first floor, then needs to correct noise level at each floor in the case of apartment building. The investigation was carried out to calculate the correction coefficient for commonly using in EIA of large scaled apartment development areas. The noised level at each floor were measured from August 2001 to March 2002 at 31 investigation points of large scaled apartment development area in national wide. Measured data were divided and treated with 4 types as 3th floor, 5th floor, 7th floor and 10th floor and then the correction coefficients of each floor were calculated using by correlation formula according to each floor.

EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발 (The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form)

  • 박철용;김상훈;장동운;장철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

건식 바닥구조의 바닥충격음 차단성능 평가 (Evaluation of Floor Impact Sound Isolation in a Dry Floor System)

  • 유진;류종관;전진용;이충화;김철환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.950-953
    • /
    • 2005
  • Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.

  • PDF

바닥충격음 측정용 표준충격원과 실충격원의 특성 비교 (Comparison of Standard Floor Impact Sources with a Human Impact Source)

  • 이평직;정정호;박준홍;전진용
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.