• Title/Summary/Keyword: Floor Impact noise

Search Result 334, Processing Time 0.025 seconds

Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source (경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석)

  • Jin, Pil-Hwa;Kim, Heung-Sik;Kim, Do-Heong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.

The numerical analysis. of heavy weight impact noise for an apartment house (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Yoon, Young-Bae;Hong, Geon-Ho;Park, Hong-Gun;Hong, Sung-Gul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

The effect of dynamic property of absorbing sheet on the amplification of heavy weight floor impact noise (완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구)

  • Hwang, J.S.;Moon, D.H.;Park, H.G.;Hong, S.G.;Hong, Geon-Ho;Lim, J.H.;Kim, Y.N.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.527-528
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6-7dB compared to the conventional slab system at the optimal stud location.

  • PDF

The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Park, Hong-Gun;Hong, Sung-Gul;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

A Study on Psycho-acoustic experiment of Two-way void Slabs and Rahmen structure (이방향 중공슬래브 및 라멘조 바닥구조의 청감평가 연구)

  • Shin, Hoon;Lee, Tai-Kang;Song, Min-Jeong;Lee, Ju-Yeob;Kim, Hyung-Geon;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.391-396
    • /
    • 2013
  • Psycho-acoustic experiments were carried out to know the inhabitant's response on floor impact noises due to floor structure types. The response values for tapping machine, bang machine and impact ball were 4.4~6.06. And children walking and adult walking were 1.67~2.97. Using 11 scale response tests, children and adult walking was not irritate to dwellers and children running was disturbing.

  • PDF

Effects of IACC and its Variation on Annoyance of Heavy-weight Floor Impact Sounds (중량충격음 어노이언스 반응에 대한 IACC 변화의 영향)

  • Kumar P. Senthil;Sato, Shin-ichi;Jeon Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.626-630
    • /
    • 2006
  • This study investigates the effects of Interaural Cross-correlation(IACC) and its variation on annoyance of the heavy-weight impact sounds. Subjects evaluated the annoyance of the heavy-weight floor impact sounds recorded in rooms of apartments which have different sound insulation treatments; furnished and occupied conditions are characterized by the ACF/IACF factors. A paired comparison test was conducted using the impact sound sources whose IACC and variation of IACC values were different. It was found that IACC is inversely correlated with the scale value(r=-0.62) whereas the variation of IACC is not(r=-0.34). On the contrary, ${\Phi}(0)$ is highly correlated with scale value of annoyance and ${\Phi}(0)$ is need to be controlled as constant to find the effect of IACC on annoyance.

  • PDF