• 제목/요약/키워드: Floor Impact Sound Test Building

검색결과 23건 처리시간 0.025초

F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책 (Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P)

  • 정정호;유승엽;이평직;전진용;조아형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF

표준실험동에서의 소음.진동 특성 (Noise and Vibration Characteristics of Floor Impact in a Test Building)

  • 정영;유승엽;이평직;정정호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2005
  • In this study, Heavy-weight floor impact sound and vibration in concrete structures with different slab thickness have been measured in a test building. It was found that natural frequency increased according to increases of slab thickness, and acceleration level decreases. Results also show that the measurements in the 210 and 240mm slab structures are complied with the result from finite element analysis but the In and 180mm slab structures are not because the structures are constrained to the ground. Therefore, in modelling process the condition of sub-structures should be examined in relation to the boundary conditions.

  • PDF

공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구 (The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room)

  • 김경우;양관섭;손장열
    • 한국음향학회지
    • /
    • 제26권6호
    • /
    • pp.235-242
    • /
    • 2007
  • 공동주택의 바닥충격음 측정 및 평가는 주로 입주 전에 이루어지고 있으나 실제 충격음 발생은 입주 후 커튼과 가구와 같은 중량물이 설치되어 있는 조건이므로 입주 전 후 음원세대(음원실)와 수음세대(수음실)의 상황은 다르다고 할 수 있다. 본 연구에서는 음원실에 가구 등과 같은 하중 설치에 따른 중량충격음 변화정도를 파악하기 위하여 바닥충격음 시험동과 현장에서 활하중($200kg/m^2$) 설치 전 후의 음원실 바닥슬래브 하부 진동가속도레벨 및 수음실 충격음레벨 변화를 측정하였다. 측정결과 하중설치를 통하여 진동가속도레벨 및 충격음레벨이 다소 저감되었으나 큰 영향은 받지 않는 것으로 나타났으며, 슬래브의 공진주파수도 변화하지 않았다.

고성능 바닥충격음 차단구조 개발에 관한 연구 (A Study on the Development of High Performance Floor Impact Noise Insulation System)

  • 장재희
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.71-76
    • /
    • 2007
  • For the many years the children's running noise has caused perpetual frictions between neighbors in apartment houses. For this reason the government established a regulation to reduce the floor impact noise, as a result almost all apartment houses have been enforced to use the floor structure with 210mm thickness concrete slab and 120mm thickness of floor heating system since July 2005. If do not want to apply this kind of system, a system which obtain the certification from the institution appointed by government must be applied. In this reason a lot of construction material companies and construction companies have been trying to develop the system with 180mm thickness concrete slab for the purpose of reducing the cost. To develop the optimized floor system, actual size test building were constructed and the materials related with reducing floor impact noise were composited and tested in the test building. Through this procedure the most effective system was found.

바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰 (Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources)

  • 이민정;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.69-79
    • /
    • 2017
  • 표준 중량 충격원의 실제 충격원 재현성에 대한 논란이 있음에도 현재 기준에서는 뱅머신 방식만 사용하고 있다. 현행 기준의 평가방법 및 등급 기준이 충격원 특성을 고려하지 못하고 있어 충격원의 선택에 따라 바닥충격음 차단 성능 등급에 차이가 발생하기 때문이다. 본 연구는 충격원 특성 외에 바닥 진동 거동 특성을 함께 고려한 현행 기준의 바닥충격음 평가 방법 고찰을 목적으로 한다. 공동주택 mock-up 실험동에서 표준 중량 충격원과 실충격원에 대하여 바닥충격음을 측정하고 이를 이용하여 해외 평가 방법과 우리나라의 평가 방법을 비교 검토하였다. 또한 현행 바닥충격음 평가 기준의 대상 주파수 범위를 벗어나는 저주파수 대역의 음압레벨은 네텔란드의 저주파 소음 인지 곡선과 국내 연구자가 제안한 저주파 소음 기준안을 이용하여 평가하였다. 그 결과 기준 및 평가 산정 방법에 따라 성능 평가 결과가 상이하며, 바닥 진동의 지배 주파수 범위에서 모든 충격원에 대한 바닥충격음 가청 소음으로 인식하여 성가시게 느낄 가능성이 매우 크다. 현행 평가 기준의 단일수치 평가량 산정 방법은 충격원에 따라 상이한 음압레벨 스펙트럼 특성을 제대로 반영하지 못하며, 바닥의 진동 거동 지배 주파수를 포함하는 저주파수 대역의 음압레벨을 고려하지 않고 있어 바닥충격음에 대한 평가 결과와 사람의 인지 수준에 차이가 발생할 수 있다. 따라서 충격원에 따른 음압레벨의 스펙트럼 특성과 저주파수 대역의 음압레벨을 반영할 수 있도록 현행 기준의 평가 방법을 보완할 필요가 있다.

바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구 (An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction.)

  • 최경석;석원균;목지욱;신이섭;김형준;김정진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

흡음 석고보드 천장재에 의한 저주파 중량 바닥충격음의 저감 효과 (Effects of sound absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound)

  • 송한솔;류종관
    • 한국음향학회지
    • /
    • 제37권5호
    • /
    • pp.323-330
    • /
    • 2018
  • 본 연구에서는 흡음 석고보드 천장재에 의한 바닥충격음 저감 효과를 조사하기 위해 잔향실에서의 흡음률 측정과 바닥충격음 성능평가 시험동에서의 바닥충격음 성능평가를 실시하였다. 먼저, 흡음률 측정은 흡음 석고보드, 흡음석고보드+글라스울, 흡음 석고보드 이중 천장재(흡음 석고보드+글라스울+흡음 석고보드)를 대상으로 실시하였다. 측정결과, 흡음 석고보드의 경우 200 Hz과 630 Hz 대역에서 약 0.1~0.5의 흡음률을 나타냈으며, 글라스울을 추가하였을 때 전체 측정 주파수대역(50 Hz ~ 630 Hz)에서 흡음률이 상승하였다. 흡음 석고보드를 추가 설치하였을 때 250 Hz 대역까지 흡음률이 크게 상승하였으나, 315 Hz 이상 대역에서는 흡음률이 감소하였다. 상기 3개의 흡음석고보드 및 일반 석고보드 천장재와 맨슬래브(천장 무) 대상으로 바닥충격음 차단 실험동에서 바닥충격음 차단성능 측정을 실시하였다. 측정결과, 흡음석고보드+글래스울과 흡음석고 보드 이중 천장재의 일반 석고보드 대비 중량충격음의 저감량은 단일평가지수 기준으로 3 dB ~ 4 dB인 것으로 나타났다. 맨슬래브 대비 중량충격음의 저감은 주로 125 Hz ~ 500 Hz 대역에서 발생하였으며 250 Hz 대역에서 최대의 저감량을 나타냈다.

1:10 축척 시험동 구조 모형의 바닥충격 진동 전달 (Propagation of floor impact vibration in a 1:10 scale model of a test structure)

  • 이평직;유승엽;김재호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1455-1458
    • /
    • 2007
  • Vibration characteristics of concrete slabs were investigated using a 1:10 scale model and finite element method. A 1:10 scale model of a test building with 150 and 200mm slab thicknesses was made of acrylic materials. Modal test was conducted to investigate mode shape and modal frequencies. Results show that the mode shapes of two slabs with different thickness are similar each other, whereas natural frequency is different. Through modal analysis using FEM, it was revealed that both mode shapes and natural frequencies calculated from the FEM model are similar to those of the scale model measurement. It was also found that natural frequencies increased with increment of the slab thickness.

  • PDF

목탄을 이용한 친환경 건축자재 이용기술(II) - 목탄 함유 건축자재의 에너지 절감 및 차음 특성에 관한 연구 (Utilization of Charcoal as an Environmentally Friendly Building Materials (II) - A Study on the Energy Saving and Sound Insulation Characteristics of Building Materials Prepared with Charcoal -)

  • 안병준;백기현
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.41-52
    • /
    • 2011
  • 본 연구는 목탄을 첨가한 건축자재의 에너지 절감 및 차음특성을 조사하기 위하여 수행되었다. 건축자재 형태에 따른 특성을 조사하기 위하여 3동의 실험 건물을 신축하였다. 이들 실험 건물은 각각 일반건축자재(A), 목탄건축자재(B) 및 목탄 sericite 건축자재(C)를 사용하여 신축하였다. 건축자재 형태별 동절기의 보일러 난방 기름소모량을 조사한 결과, B를 사용할 경우 A를 사용한 건물과 비교하여 평균 9.5%, C를 사용할 경우에는 평균 14.9%의 기름절감 효과를 나타냈다. 특히 기름 절감효과는 외부기온이 낮을수록 큰 것으로 조사되었다. 또한 B를 적용한 건물은 A나 C를 사용한 건물과 비교하여, 난방온도가 상당히 완만하게 낮아졌으며, 보일러 가동 중단 12시간 경과 후 지상 1미터 공기부에서 $3.5{\sim}4.2^{\circ}C$, 바닥표면에서는 $4.4{\sim}5.4^{\circ}C$ 높게 나타났다. 건물 소음시험에 있어서는, 목탄을 포함하는 시험체는 다층건물의 층간소음 기준으로 대표되는 중량충격음과 경량충격음 모두에서 저감효과를 나타냈다.

완충재 장기처짐과 ISO 20392 대응 연구 (Correspondence Research of Long-term Compressive Creep of Resilient Materials and ISO 20392)

  • 김경우;연준오;양관섭
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1250-1256
    • /
    • 2012
  • Resilient materials are used to reduce the floor impact sound in apartment buildings. Since an on-dol layer is installed in the resilient materials' upper part, thickness deformation can be occur in the resilient material. It is necessary to check a thickness deformation grade for a long period of time. In this research, we measured thickness deformation over 400th day to the resilient materials(EPP, EPS, EVA) which is used in Korea. Although there was a difference according to the kind of measurement test specimens, it became clear that thickness was decreases as to time increased. The thickness deformation grade of ten years after was calculated based on the thickness measurement result. Compare with the calculated result and result of ISO 20392. Larger thickness deformation occurred in the measurement result of these research findings compare with the ISO standard.