• Title/Summary/Keyword: Floor Area

Search Result 1,183, Processing Time 0.036 seconds

A Study on Gathering Behaviour of Fish in the Artificial Sea-floor Area (인공해저에 대한 어류의 위집기구에 관한 연구)

  • 홍성완
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.96-104
    • /
    • 2000
  • By using the offshore type submersible platform, Artificial sea floor anchored at a depth of forty meters several experimental studies have been conducted successfully during 1996. The facility consists of an artificial sea floor that floats at 7 meters below the surface, a machinery hut that projects above the surface at the center of the structure and a balance weight beneath the structure. The facility can be surfaced easily by using a water discharging pump in the water tank which is located at the center of it. To find out the behavioral character and the gathering factor of fishes around the artificial sea floor, investigations were carried out during the daytime and nighttime by direct observation and by echo-sounder. Around the testing reefs and artificial sea floor, six kinds of fishes were found by diving observation and the dominants were Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. As Scomber japonicus was distributed around the artificial sea floor in dense small school, they were not seen elsewhere in the survey area. The artificial sea floor was concluded to act as a schooling ground far Scomber japonicus, Sebastes thompsoni and Oplegnathus fascitus. were close to the testing reefs(within 10m) in the daytime, and were thought to settle on the testing reefs at nighttime, To examine the distribution of 7shes around the artificial sea floor, an acoustic survey over a 1$\times$1km area, 0-50m in depth during the all day. Around the artificial sea floor many thin scattering fish echo(TS-54.5~ -51.5dB) and dense fish echo(TS-41~-38dB) were mainly distributed. Many scattering fish echoes, which were thought to be a mixture of small squid, pelegic crustacea and ethers, were distributed over the whole survey area. A dense fish school stayed beneath the artificial sea floor for a short duration. These phenomena were concluded to show an attraction and detention function of the artificial sea floor.

  • PDF

Effects of semi-floor pens on growth performance and stress in weaning pigs (사육면적 증가를 위한 반층돈사의 활용이 이유자돈의 성장 및 스트레스에 미치는 영향)

  • Chung, Woolim;Lee, Geonil;Hong, Jinsu;Jeong, Jaehark;Kim, Yooyong
    • Journal of Animal Environmental Science
    • /
    • v.22 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The objective of this study was to increased breeding area in same size pig pen and growth performance of weaning pigs. A total of 330 crossbred ($6.68{\pm}0.36kg$) weaning pigs were subjected to a 42-day feeding trial(3 pens/treatment) in which effects of the semi-floor were compared : NC; Negative control ($0.23m^2/pig$; 40 pigs/pen), PC; Positive control($0.30m^2/pig$; 30 pigs/pen) and Semi-floor($0.30m^2/pig$; 40 pigs/pen). There was a significant effect on BW at 6 week along all treatment(P<0.01). There was a effect of Semi-floor treatment on ADG(average daily gain) only during the first 3 week after weaning(P<0.01). No significant effect was observed in the ADFI during the experiment period. NC treatment had significantly lower BUN value than other treatments(P<0.05). The results from immune and stress response with semi-floor suggest that no negative effects in their blood analysis. Consequently, semi floor treatments increased additional breeding area and also growth performance rather than other treatments in weaning pigs.

Thermal Characteristics of a Partition Supply System

  • Jeong, Ky-Bum
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.67-72
    • /
    • 2003
  • A partition integrated air supply system can provide highly personalized environmental control. The supply air is brought up through raised floors and supplied to outlets located on the partition panels. The purpose of this paper is to find out the best design of outlets for optimal occupant comfort within a personal task area. Real scale experiments were conducted to allow for comparisons of outlet designs within a personal task area. Experimental results indicate that the location of an outlet is the most critical factor in improving the efficiency of supply air distribution of a personal task area. Thermal characteristic comparisons were made between the under-floor and the partition supply systems. Experimental results suggest that the partition supply system is more efficient than the under-floor supply system in terms of cooling. Such a system allows occupants to personally control their immediate environment, resulting in higher productivity.

An Analysis of the Unit Plan Characteristics for the Apartments at Metropolitan Seoul Area in the Context of Space Syntax Model (아파트 단위주거 평면의 규모별 공간구성에 관한 기초 연구)

  • 이동원;오도엽
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2004
  • The purpose of this study is to analyze spatial configuration of the unit floor plan characteristics of the apartments built in Seoul Metropolitan area by using the Space Syntax methodology and finally to test the relationship between space in the unit floor plans. So the unit floor plans are analyzed using sector graphs from justified graph and computer programs based on the Space Syntax model and compared by size. The results are as follows; The sector graphs are summarized in 14 types. The total depth of spaces is not in proportion to the plan area. And the global and local integration and intelligibility are inversely proportional to the area. But in the case of largest areas(265$m^2$ and above), the integration and intelligibility increase.

A Study on the Architectural Planning of traditional herbal medicine distribution supporting facilities (한약재유통지원시설의 건축계획에 관한 연구)

  • Bae, Joa-Sup;Oh, Jong-Hee;Kang, Won-Pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.2
    • /
    • pp.53-64
    • /
    • 2008
  • This study is the architectural planning of 5 distribution supporting facilities for traditional herbal medicine cultivated in the rural areas. The main function of the facility consists of storage, pre-treatment/processing, loading/unloading and the assistant function consists of inspection, office, exhibition/sale, technical equipment etc. The planning shows the modular plan and the section plan of the storage space reflecting the shape and size of storage container, the action radius of carrier and the possibilities of space lease. The total floor area of the storage is 3,192$m^2$ consisting of 27 space. The total floor area of the pre-treatment/processing is 1,488$m^2$ consisting of 7 space. The total floor area of the loading/unloading is 329$m^2$ consisting of 4 space. The total floor area of each facility storage is 8,284$m^2$ including of public space 2,170$m^2$. Also this planning shows the preliminary design, "fundamental model design" for 5 rural government BTL project. Therefore, this result of planning will be the guidelines of the RFP(Request For Proposal) for the private sector company interested in this BTL project.

  • PDF

Development of Traffic Accident Forecasting Models Considering Urban-Transportation System Characteristics (토지이용 및 교통특성을 반영한 교통사고 예측모형 개발 연구)

  • Park, Jun-Tae;Jang, Il-Jun;Son, Ui-Yeong;Lee, Su-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.6
    • /
    • pp.39-56
    • /
    • 2011
  • This study proposed a traffic accident prediction model developed based on administrative districts of Seoul. The model was to find the relationship between accident rates and the representative land usage of the districts (development density) - the higher the development density (building floor area) is, the higher the traffic accident rate is. The findings showed that traffic accident statistics differ from (1) residential building floor area, (2) commercial building floor area and (3) business building floor area.

A Computer Code for an Optimum Design of Solar Space and Domestic Hot Water Heating System (태양열주택 및 가정용 태양 온수시스템의 설계용 전산코드)

  • Im, D.J.;Chun, M.H.;Yoon, S.B.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.37-42
    • /
    • 1984
  • A computer code for an optimum design of solar space and domestic hot water heating system has been developed. The f-chart method developed by S.A. Klein et al. has been incorporated in the present computer code. The main conclusions obtained from the present work may be summarized as follows: (1) In Seoul area, about 46% of the total heating load can be obtained from the solar collectors whose total surface area is about one-third of the total heating floor area. (2) In Pusan area, total area of solar collectors should be about half of the total heating floor area in order to obtain an equivalent solar fraction of Seoul. (3) In cheju area, on the other hand, only about 42% of the total heating floor area of solar collectors is needed to get the same solar fraction as in Seoul and Pusan. (4) In order to get the first 50% solar fraction, only about 10-14 collectors ($4'{\times}8'$ collectors) are required, whereas about 48 collectors are needed to obtain the solar fraction of 100%. That is, roughly 3.5-4.5 times greater number of collectors are required to increase the solar fraction from 50% to 100%. Therefore, it can be concluded that it is relatively inefficient and less economical to build a solar system whose solar fraction exceeds more than 50%.

  • PDF

A Study on the Characteristics of the Folk Houses in the Upper Area of Seomjin River -focused on the generating housing floor plans- (섬진강 상류 지역의 민가건축에 관한 연구 -평명유형을 중심으로-)

  • 남해경;허성제
    • Journal of the Korean housing association
    • /
    • v.11 no.3
    • /
    • pp.43-51
    • /
    • 2000
  • This study aims to find the characteristics of the folk houses in the upper area of Seomjin river in the view point of generating housing floor plans by their human and natural elements of environment. Because they are formed differently as them and have the characteristics as the houses in the upper area of Seomjin river. Seomjin river flows from mid-west area of the Korean peninsula to the southern sea. This is about 212.3km long and the fourth in the south of the Korean peninsula. It is surrounded high mountains in the upper area and makes open field in the mid and lower area of river. The study is surveyed and analyzed to the folk houses of the middle and lower class people in the area of Seomjin river. Because they have been formed by their natural and human elements of environment gradually. They are 35 houses - 13 in Jinan-kun, 4 in Imsil-kun, 10 in Namwon city, 10 in Sunchang-kun. They are analyzed by their floor plans and their spatial relations. The result of this study is that they are made by their natural and human elements of environment. There are some houses with semi-several wings and with storage that are appeared in the mountain village. It reflects that they are surrounded by high mountains. And there are some houses with wooden floor room that are appeared in the area of river little in the area of mountain. To prevent wind from the river the houses are layouted as a form . open ㄴ type, open ㄷ type, and their wall is made of stone and planted bamboo trees around their houses.

  • PDF

Sensory change and recovery of infraorbital area after zygomaticomaxillary and orbital floor fractures

  • Sang Woo, Han;Jeong Ho, Kim;Sug Won, Kim;Sung Hwa, Kim;Dae Ryong, Kang;Jiye, Kim
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.262-268
    • /
    • 2022
  • Background: To compare the sensory change and recovery of infraorbital area associated with zygomaticomaxillary and orbital floor fractures and their recoveries and investigate the factors that affect them. Methods: We retrospectively reviewed 652 patients diagnosed with zygomaticomaxillary (n= 430) or orbital floor (n= 222) fractures in a single center between January 2016 and January 2021. Patient data, including age, sex, medical history, injury mechanism, Knight and North classification (in zygomaticomaxillary fracture cases), injury indication for surgery (in orbital floor cases), combined injury, sensory change, and recovery period, were reviewed. The chi-square test was used for statistical analysis. Results: Orbital floor fractures occurred more frequently in younger patients than zygomaticomaxillary fractures (p< 0.001). High-energy injuries were more likely to be associated with zygomaticomaxillary fractures (p< 0.001), whereas low-energy injuries were more likely to be associated with orbital floor fractures (p< 0.001). The sensory changes associated with orbital floor and zygomaticomaxillary fractures were not significantly different (p= 0.773). Sensory recovery was more rapid and better after orbital floor than after zygomaticomaxillary fractures; however, the difference was not significantly different. Additionally, the low-energy group showed a higher incidence of sensory changes than the high-energy group, but the difference was not statistically significant (p= 0.512). Permanent sensory changes were more frequent in the high-energy group, the difference was statistically significant (p= 0.043). Conclusion: The study found no significant difference in the incidence of sensory changes associated with orbital floor and zygomaticomaxillary fractures. In case of orbital floor fractures and high-energy injuries, the risk of permanent sensory impairment should be considered.

Minimum Floor Area Ratio Estimation Model for Reconstruction Projects to Compensate for Loss of the Aged Long-term Public Rental Housing (노후 장기공공임대주택 손실보전을 위한 재건축사업의 최소용적률 수리모델)

  • Joe, Wongoog;Na, Seunguk;Cho, Jeaho;Chae, MyungJin;Son, Bosik;Kim, Hyunsoo;Chun, JaeYoul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.5
    • /
    • pp.108-116
    • /
    • 2022
  • Started in 1989 as Public Permanent Rental Housing scheme, public rental housing lease policy is increasing target residents and supply in each government by introducing new supply types. However, public housing business entities have difficulties in expanding the supply due to cumulated deficit. The research suggested long-term public rental housing reconstruction business as a method to preserve the cumulated deficit from the previous. Minimum floor area ratio mathematical model was suggested by defining the floor area ratio of reconstruction business as minimum, since housing sales profit after reconstruction could preserve aggregated deficit, and mathematically approached by considering the traits of long-term public rental housing reconstruction. The determinant for minimum floor area ratio mathematical model comprise cumulated deficit of the existing long-term public rental housing, land size of reconstructed sale housing, housing sales price per unit area, and business cost per unit area. Minimum floor area ratio mathematical model is expected to be the milestone for supporting decision making regarding the economic part of old long-term public lease housings' reconstruction scale, and expanding housing supply within urban area.