• 제목/요약/키워드: Floor

검색결과 6,143건 처리시간 0.034초

건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 - (Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure -)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

건축물 바닥재의 마모에 따른 미끄럼성능 변동에 관한 연구 (A Study on the Change of Slipperiness of Building Floor-coverings by Friction Wear)

  • 신윤호;최수경
    • 한국건축시공학회지
    • /
    • 제5권1호
    • /
    • pp.53-61
    • /
    • 2005
  • The purpose of this study presents useful data on the choice or development of floor covering from slip viewpoint by examining closely the impact of the changes in sliding experiments due to the wear of floor covering by walk. The result of wear practical test per ten thousand walks enforces some kind of popular floor covering and measure of coefficient of slip resistance as follows: (1) When surface of floor covering is in the state of wet, the degree of wear doesn't affect greatly in slip. (2) When surface of floor covering is in dry and clean state, most floor coverings have the tendency to lower the coefficient of slip resistance with the amount of walk on it. (3) Change in the tendency of slip resistance by wear appeared mainly due to the differences in the state of floor covering and organic floor covering appeared to have great reduction of coefficient of slip resistance than the inorganic ones. (4) According to the result of investigation on changes in tendency of coefficient of slip resistance due to the increase in the number of walk and if two hundred thousand walks were done, regardless of surface shape or kind of site, etc, the safety of floor covering, in slip viewpoint, greatly reduces.

콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음 (Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers)

  • 문대호;오양기;정갑철;박홍근
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가 (A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam)

  • 노영숙;윤성호
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

Pelvic Floor Muscle Exercise by Biofeedback and Electrical Stimulation to Reinforce the Pelvic Floor Muscle after Normal Delivery

  • Lee, In-Sook;Choi, Euy-Soon
    • 대한간호학회지
    • /
    • 제36권8호
    • /
    • pp.1374-1380
    • /
    • 2006
  • Purpose. This study was conducted to investigate the effectiveness of pelvic floor muscle exercise using biofeedback and electrical stimulation after normal delivery. Methods. The subjects of this study were 49 (experimental group: 25, control group: 24) postpartum women who passed 6 weeks after normal delivery without complication of pregnancy, delivery and postpartum. The experimental group was applied to the pelvic muscle enforcement program by biofeedback and electrical stimulation for 30 minutes per session, twice a week for 6 weeks, after then self-exercise of pelvic floor muscle was done 50-60 repetition per session, 3 times a day for 6 weeks. Maximum pressure of pelvic floor muscle contraction (MPPFMC), average pressure of pelvic floor muscle contraction (APPFMC), duration time of pelvic floor muscle contraction (DTPFMC) and the subjective lower urinary symptoms were measured by digital perineometer and Bristol Female Urinary Symptom Questionnaire and compared between two groups prior to trial, at the end of treatment and 6 weeks after treatment. Results. The results of this study indicated that MPPFMC, APPFMC, DTPFMC were significantly increased and subjective lower urinary symptoms were significantly decreased after treatment in the experimental group than in the control group. Conclusions. This study suggested that the pelvic floor muscle exercise using biofeedback and electrical stimulation might be a safer and more effective program for reinforcing pelvic floor muscle after normal delivery.

벽식구조 공동주택의 바닥충격음 개선에 대한 연구 (A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment)

  • 김선우
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

NDVI RESPONSES TO THE FOREST CANOPY AND FLOOR IN EASTERN SIBERIA

  • Suzuki, Rikie;Kobayashi, Hideki;Delbart, Nicolas;Hiyama, Tetsuya;Asanuma, Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.325-328
    • /
    • 2007
  • We discuss the Normalized Difference Vegetation Index (NDVI) of the forest canopy and floor separately based on airborne spectral reflectance measurements and simultaneous airborne land surface images acquired around Yakutsk, Siberia in 2000. The aerial land surface images were visually classified into four forest types: no-green canopy and snow floor (Type-1), green canopy and snow floor (Type-2), no-green canopy and no-snow floor (Type-3), and green canopy and no-snow floor (Type-4). The mean NDVI was calculated for these four types. Although Type-2 had green canopy, the NDVI was rather small (0.17) because of high reflection from the snow cover on the floor. Type-3, which had no green canopy, indicated considerably large NDVI (0.45) due to the greenness of the floor. Type-4 had the largest NDVI (0.75) because of the greenness of both the canopy and floor. These results reveal that the NDVI depends considerably on forest floor greenness and snow cover in addition to canopy greenness.

  • PDF

시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석 (An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis)

  • 문대호;박홍근;황재승;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제24권5호
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구 (A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump)

  • 이병두;이세진;이대우;오성해;남우동
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

도로변 공동주택의 층별 소음보정계수 산정에 관한 연구 (A study on the Calculation of Noise Correction Coefficient on each floor for the estimation on the roadside traffic noise around the Apartment Building)

  • 박영민;이지왕;고정용
    • 환경영향평가
    • /
    • 제14권1호
    • /
    • pp.25-36
    • /
    • 2005
  • Actually, prediction formula of road traffic noise for EIA(Environmental Impact Assessment) has been used that proposed by National Institute of Environmental Research in 1999. The prediction formula, however, was calculated predicted noise level according to noise level producing on first floor, then needs to correct noise level at each floor in the case of apartment building. The investigation was carried out to calculate the correction coefficient for commonly using in EIA of large scaled apartment development areas. The noised level at each floor were measured from August 2001 to March 2002 at 31 investigation points of large scaled apartment development area in national wide. Measured data were divided and treated with 4 types as 3th floor, 5th floor, 7th floor and 10th floor and then the correction coefficients of each floor were calculated using by correlation formula according to each floor.