• Title/Summary/Keyword: Floor

Search Result 6,091, Processing Time 0.05 seconds

The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength (콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안)

  • 남상욱;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

A Study on Application of Radiant Floor Heating in Large Space (대공간의 바닥 복사 난방 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.79-85
    • /
    • 2007
  • This paper addresses the indoor air quality when radiant floor heating is applied in large space. Radiant heat exchange between surfaces depends on the orientation and the temperature of the surfaces. Also, the temperature and the radiant characteristic of the wall and the roof that face the floor have great influence on the indoor air environment due to the largeness of the wall and the roof in large spaces. In this study, we simulate a test-cell(25X20X10) using a ies YE And using a CFD(microflo in VE), an indoor air environment was investigated to establish the optimum temperature of floor. At the first time of the heating, high floor temperature is demanded. At the middle of the heating, however, the temperature of the residential space was formed appropriately, although the temperature of the floor was set low.

An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings (완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구)

  • Youn, Se Cheol;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

A Study on the Development of High Performance Floor Impact Noise Insulation System (고성능 바닥충격음 차단구조 개발에 관한 연구)

  • Jang, Jae-Hee
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.71-76
    • /
    • 2007
  • For the many years the children's running noise has caused perpetual frictions between neighbors in apartment houses. For this reason the government established a regulation to reduce the floor impact noise, as a result almost all apartment houses have been enforced to use the floor structure with 210mm thickness concrete slab and 120mm thickness of floor heating system since July 2005. If do not want to apply this kind of system, a system which obtain the certification from the institution appointed by government must be applied. In this reason a lot of construction material companies and construction companies have been trying to develop the system with 180mm thickness concrete slab for the purpose of reducing the cost. To develop the optimized floor system, actual size test building were constructed and the materials related with reducing floor impact noise were composited and tested in the test building. Through this procedure the most effective system was found.

Hybrid Shop Floor Control System for Computer Integrated Manufacturing (CIM)

  • Park, Kyung-Hyun;Lee, Seok-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.544-554
    • /
    • 2001
  • A shop floor can be considered as an important level to develop Computer Integrated Manufacturing system (CIMs). However, a shop floor is a dynamic environment where unexpected events continuously occur, and impose changes to the planned activities. To deal with this problem, a shop floor should adopt an appropriate control system that is responsible for the coordination and control of the manufacturing physical flow and information flow. In this paper, a hybrid control system is described with a shop floor activity methodology called Multi-Layered Task Initiation Diagram (MTD). The architecture of the control model contains three levels: i.e., he shop floor controller (SFC), the intelligent agent controller (IAC) and the equipment controller (EC). The methodology behind the development of the control system is an intelligent multi-agent paradigm that enables the shop floor control system to be an independent, an autonomous, and distributed system, and to achieve an adaptability to change of the manufacturing environment.

  • PDF

Dynamic analysis of the floor structures with different floor plans in apartments (아파트 평면형상에 따른 바닥판의 동특성 해석)

  • Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1459-1462
    • /
    • 2007
  • In this study, vibration characteristics of concrete slab were investigated through FEM analysis. Four different floor plans with the floor area of $100{\sim}130m^2$ were chosen to be analyzed. Boundary conditions of two dimensional finite element models were determined based on the modal test results. Results showed that mode shapes were formed somewhat different according to the floor plan and the contribution of 1st mode on the floor vibration is generally the highest. Through the transient analysis, it was also found that floor plan, expecially connection of the living room with the kitchen, affected the vibration acceleration levels.

  • PDF

Motion Analysis and Dynamic Characteristics of the Concrete Floor Finishing Robot with Deformable Trowels (미장로봇의 운동해석과 동특성 분석)

  • Kim, Jin-Ho;Sin, Dong-Heon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.193-200
    • /
    • 2001
  • Recently, the concrete floor finishing robot, which can be used for flattening and smoothing the concrete floor, has been developed in Korea and Japan. While the previous research assumes that the concrete floor is deformable and the trowel is rigid in modeling the concrete floor finisher, we assume that the concrete floor is rigid and the trowel is deformable. Based on this assumption, we derived the equations of motion and found the convergent velocity of the concrete floor finisher using the computer simulation. From these results, we can understand the relationship between the motion characteristics and the design and control parameter of the robot.

  • PDF

The Relationship Between Cage Floor Preferences and Performance in Broiler Chickens

  • Zulkifli, I.;Khatijah, A. Siti
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.3
    • /
    • pp.234-238
    • /
    • 1998
  • Two experiments were conducted with broiler chickens to determine cage floor preferences, the strength of preference for a particular floor type and to evaluate the effect of rearing broilers on the preferred cage floor on productivity. In experiment 1, chicks when offered free access to either wire (WF) or plastic (PF) mesh flooring, preferred the former. However, when the perferred floor type (WF) was illuminated at 800 lux, birds spent longer time on PF. Also provision of incandescent lamps at PF resulted in broilers spending significantly longer period on WF. In experiment 2, while floor type had no effect on growth of female chicks throughout the duration of study, male chicks grown on PF were heavier than their WF counterparts on Days 21, 28, 35 and 42. Neither livability, nor incidence of breast blisters and leg deformities was affected by floor type.

An Experimental Study on the Floor Impact Sound Insulation of Apartment depending on the Plane Shape of Living-Room (거실평면형태에 따른 공동주택 바닥충격음 차음특성 변화에 관한 실험적 연구)

  • Park, Hyeon-Ku;Park, Chan-Wong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.844-847
    • /
    • 2008
  • As customer's demands are varying, the type of floor plan of apartment is changed into expanded type with balcony unified to living room from general type with balcony separated from living room and so is changing the layout of L(living room), D(dining room) and K(kitchen). This study aims to examine how the type of floor plan of living room affects the floor impact sound insulation performance and to propose fundamental idea to floor plan layout of apartment in terms of floor impact sound reduction.

  • PDF

An Efficient Vibration Analysis of the Floors in Residential Building (주거용 건축물의 효율적인 바닥진동해석)

  • Kim, Tae-Ho;Lee, Dong-Guen
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.228-235
    • /
    • 2005
  • The floor impact sound insulations are installed frequently for reducing the floor impact sound into the floor slab of the residential buildings in recent years. Therefore the analytical FE model considering the insulations is needed for the sound and vibration analysis of the floor and it is necessary to use a refined finite element model for considering the large number of modes involving in the dynamic responses. So it is very difficult to use FE model because of the tiresome task for constructing the FE model, taking a lot of times for analysis and the impossibility of using the proportional damping. The efficient analysis and modeling method are proposed to the dynamic analysis for the floor with floor impact sound insulations in this study. The floor slabs and finished layers are modeled individually and the spring elements that mean floor impact sound insulations use to connect two parts. The dynamic analysis by the $Newmark-{\beta}$ method is performed to solve the non-proportional damping problem due to the damping coefficient of insulations .

  • PDF