• Title/Summary/Keyword: Floating to Surface

Search Result 357, Processing Time 0.027 seconds

Study on Real-Time Digital Filter Design as Function of Scanning Frequency of Focused Electron Beam (집속 전자 빔 장치에서 스캔 주파수에 따른 실시간 디지털 필터 설계에 관한 연구)

  • Kim, Seung-Jae;Oh, Se-Kyu;Yang, Kyung-Sun;Jung, Kwang-Oh;Kim, Dong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.479-485
    • /
    • 2011
  • To acquire images in a thermionic-scanning electron-beam system, a scanning unit is needed to control the electron beam emitted from the tungsten filament source. In scanning the electron beam on the solid surface, the signalto-noise ratio depends on the scanning frequency. We used a digital filter to reduce noise by analyzing the real-time frequency of a secondary electron signal. The noise and the true image signal were well separated. We designed the digital filter via a DSP floating-point operation, and the noise elimination resulted in enhanced image quality in a highresolution mode.

Induced Spawning of Red Sea Bream, Pagrus major, by Controlling Photoperiod and Water Temperature (참돔, Pagrus major의 광주기 및 수온조절에 따른 조기산란)

  • Kim Hyung-Bae;Kim Jong-Man
    • Journal of Aquaculture
    • /
    • v.3 no.1
    • /
    • pp.1-11
    • /
    • 1990
  • To induce an early spawning, the adult red sea bream, Pagrus major, were exposed to predesignated condition of photoperiod and water temperature during February 21 to June 30, 1988. Spawning began from April 20, a month earlier than that in the natural condition, when the photoperiod and water temperature were controlled at 14L: l0D and $17.0^{\circ}C$, respectively, and the spawning continued until June 15, 1988. There were no particular differences between fish under the controlled condition and those in natural condition in terms of the fertilization rate, surface floating rate, the number of oil glouble and the hatching rate.

  • PDF

A Study on the Cultivation of Enteromorpha prolifera(Muller) J.Agardh, Chlorophyta in Korea (녹조식물 가시파래, Enteromorpha prolifera의 양식연구)

  • 윤장택;조용철;공용근
    • Journal of Aquaculture
    • /
    • v.16 no.1
    • /
    • pp.44-50
    • /
    • 2003
  • This study aimed to develop the methods of growing Enteromorpha prolifera natural seedlings in its natural habitat and artificial indoor seedlings by inducing spore release. Likewise, the study examined the possibility of mass production by developing cultivation techniques with cultivating examination. The natural seedling of E.prolifera thrived in a sea area composed of sand and mud, which Is its natural habitat. Growing of this alga on the seedling frame 20 cm high from the bottom at the intertidal zone in summer and 40 cm high in fall was found to be very effective. However, enabling the best attachment rate for artificial indoor seedling requires inducing spore release after drying the mature thalli in a dark place fur about 12∼24 hours and setting seedling nets in a dark water tank (spore solution) for 24 hours. Breeding E.prolifera in a pole-system farm is best done in shallow sea areas with mud or mud and sand geological feature. However, floating-system lam is better for deep-sea areas with fast current. Ideal farming places are sea areas with plenty of nutritional salt and safe places that protect the lam facilities against billows. Furthermore, an exposure method on seawater surface to produce larger output should be used.

Semi-Analytical Methods for Different Problems of Diffraction-Radiation by Vertical Circular Cylinders

  • Malenica, Sime
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.2
    • /
    • pp.116-138
    • /
    • 2012
  • As in the other fields of mechanics, analytical methods represent an important analysis tool in marine hydrodynamics. The analytical approach is interesting for different reasons : it gives reference results for numerical codes verification, it gives physical insight into some complicated problems, it can be used as a simplified predesign tool, etc. This approach is of course limited to some simplified geometries (cylinders, spheres, ...), and only the case of one or more cylinders, truncated or not, will be considered here. Presented methods are basically eigenfunction expansions whose complexity depends on the boundary conditions. The hydrodynamic boundary value problem (BVP) is formulated within the usual assumptions of potential flow and is additionally simplified by the perturbation method. By using this approach, the highly nonlinear problem decomposes into its linear part and the higher order (second, third, ...) corrections. Also, periodicity is assumed so that the time dependence can be factorized i.e. the frequency domain formulation is adopted. As far as free surface flows are concerned, only cases without or with small forward speed are sufficiently simple to be solved semi-analytically. The problem of the floating body advancing in waves with arbitrary forward speed is far more complicated. These remarks are also valid for the general numerical methods where the case of arbitrary forward speed, even linearized, is still too difficult from numerical point of view, and "it is fair to say that there exists at present no general practical numerical method for the wave resistance problem" [9], and even less for the general seakeeping problem. We note also that, in the case of bluff bodies like cylinders, the assumptions of the potential flow are justified only if the forward speed is less than the product of wave amplitude with wave frequency.

The Second Animal Tests of Artificial Heart Valves (인공심장판막의 개발과 동물실험 -인공심장판막의 2차 동물실험-)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.617-621
    • /
    • 1990
  • A heart supplies blood of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to accomplish these enormous work of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of blood. In an attempt to eliminate the affliction of heart valves, the operative method to replace with artificial heart valves has developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. New artificial heart valves have been developed in Korea Advanced Institute of Science and Technology since early 1980`s. The first developed valve was designed with a free-floating pyrolytic carbon disk that is suspended in a titanium cage. The design of the valve was tested in vitro, and in animals in 1987. The results from this study was that the eccentrically placed struts creates a major and minor orifice when the disc opens and stagnation of flow in the area of the minor orifice has led to valve thrombosis. In this work, the design of the valve was changed from a single - leaflet valve to double - leaflet one in order to resolve the problems observed in the first - year tests. Morphological and hemodynamic studies were made for the newly designed valves through the in vitro and in vivo tests. The design and partial materials of the artificial heart valve was improved comparing with first - year`s model. The disc in the valve was modified from single - leaflet to bi - leaflet, and the material of the cage was changed from titanium metal to silicon - alloyed pyrolytic carbon. A test was made for the valve in order to examine its mechanical performance and stability. Morphological and hemodynamic studies were made for the valve that had been implanted in tricuspid position of mongrel dogs. All the test animals were observed just before the deaths. A new artificial heart valve was designed and fabricated in order to resolve the problems observed in the old model. The new valve was verified to have good stability and high resistance to wear through the performance tests. The hemodynamic properties of the valve after implantation were also estimated to be good in animal tests. Therefore, the results suggest that the newly designed valve in this work has a good quality in view of the biocompatibility. However, valve thrombosis on valve leaflets and annulus were found. This morphological findings were in accordance with results of surface polishing status studies, indicating that a technique of fine polishing of the surface is necessary to develop a valve with higher quality and performance.

  • PDF

Design Optimization to achieve an enhanced flatness of a Lab-on-a-Disc for liquid biopsy (액체생검용 Lab-on-a-Disc의 평탄도 향상을 위한 최적화)

  • Seokkwan Hong;Jeong-Won Lee;Taek Yong Hwang;Sung-Hun Lee;Kyung-Tae Kim;Tae Gon Kang;Chul Jin Hwang
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.20-26
    • /
    • 2023
  • Lab-on-a-disc is a circular disc shape of cartridge that can be used for blood-based liquid biopsy to diagnose an early stage of cancer. Currently, liquid biopsies are regarded as a time-consuming process, and require sophisticated skills to precisely separate cell-free DNA (cfDNA) and circulating tumor cells (CTCs) floating in the bloodstream for accurate diagnosis. However, by applying the lab-on-a-disc to liquid biopsy, the entire process can be operated automatically. To do so, the lab-on-a-disc should be designed to prevent blood leakage during the centrifugation, transport, and dilution of blood inside the lab-on-a-disc in the process of liquid biopsy. In this study, the main components of lab-on-a-disc for liquid biopsy are fabricated by injection molding for mass production, and ultrasonic welding is employed to ensure the bonding strength between the components. To guarantee accurate ultrasonic welding, the flatness of the components is optimized numerically by using the response surface methodology with four main injection molding processing parameters, including the mold & resin temperatures, the injection speed, and the packing pressure. The 27 times finite element analyses using Moldflow® reveal that the injection time and the packing pressure are the critical factors affecting the flatness of the components with an optimal set of values for all four processing parameters. To further improve the flatness of the lab-on-a-disc components for stable mass production, a quarter-disc shape of lab-on-a-disc with a radius of 75 mm is used instead of a full circular shape of the disc, and this significantly decreases the standard deviation of flatness to 30% due to the reduced overall length of the injection molded components by one-half. Moreover, it is also beneficial to use a quarter disc shape to manage the deviation of flatness under 3 sigma limits.

  • PDF

Atmospheric Bioaerosol, Bacillus sp., at an Altitude of 3,500 m over the Noto Peninsula: Direct Sampling via Aircraft

  • Kobayashi, Fumihisa;Morosawa, Shinji;Maki, Teruya;Kakikawa, Makiko;Yamada, Maromu;Tobo, Yutaka;Hon, Chun-Sang;Matsuki, Atsushi;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.164-171
    • /
    • 2011
  • This work focuses on the analysis of bioaerosols in the atmosphere at higher altitudes over Noto Peninsula, Japan. We carried out direct sampling via aircraft, separated cultures, and identified present isolates. Atmospheric bioaerosols at higher altitudes were collected using a Cessna 404 aircraft for an hour at an altitude of 3,500 m over the Noto Peninsula. The aircraft-based direct sampling system was devised to improve upon the system of balloon-based sampling. In order to examine pre-existing microorganism contamination on the surface of the aircraft body, bioaerosol sampling was carried out just before takeoff using the same method as atmospheric sampling. Identification was carried out by a homology search for 16S or 18S rDNA isolate sequences in DNA databases (GenBank). Isolate sampling just before takeoff revealed Stretpomyces sp., Micrococcus sp., and Cladosporium sp. One additional strain, Bacillus sp., was isolated from the sample after bioaerosol collection at high altitude. As the microorganism contamination on the aircraft body before takeoff differed from that while in the air, the presence of additional, higher atmosphere-based microorganisms was confirmed. It was found that Bacillus sp. was floating at an altitude of 3,500 m over Noto Peninsula.

Development of Model Test Methodology of Pack Ice in Square Type Ice Tank (사각 빙해수조에서의 Pack Ice 모형시험 기법 개발)

  • Cho, Seong-Rak;Yoo, Chang-Soo;Jeong, Seong-Yeob
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.5
    • /
    • pp.390-395
    • /
    • 2011
  • The main purpose of ice model basin is to assess and evaluate the performance of the Arctic ships and offshore structures because the full-scale tests in ice covered sea are usually very expensive and difficult. There are various ice conditions, such as level ice, brash ice, pack ice and ice ridge, in the real sea. To estimate their capacities in ice tank accurately, an appropriate model ice sheet and prepared ice conditions copied from actual sea ice conditions are needed. Pack ice is a floating ice that has been driven together into a single mass and a mixture of ice fragments of varying size and age that are squeezed together and cover the sea surface with little or no open water. So Ice-class vessels and Icebreaker are usually operated in pack ice conditions for the long time of her voyage. The most ice model tests include the pack ice test with the change of pack ice concentration. In this paper, the effect of pack ice size and channel breadth in pack ice model test is conducted and analyzed. Also we presented some techniques for the calculation of pack ice concentration in the model test. Finally, we developed a new model test methodology of pack ice condition in square type ice tank.

Photo Displacement Properties of Nano structure Organic Ultra Thin Films (통신용 부품제작을 위한 유기초박막의 전자특성에 관한 연구)

  • Song, Jin-Won;Cho, Su-Young;Kim, Young-Gun;Kim, Hyung-Gon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11b
    • /
    • pp.27-32
    • /
    • 2004
  • Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. MDC flowing across monolayers is analyzed using a rod-like molecular model. A method for determining the dielectric relaxation time ${\tau}$ of floating 'monolayers on the water surface is presented. MDC floing across monolayers is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time ${\tau}$ of monolayers in the isotropic polar orientational phase is determined using a liner relationship between the monolayer compression speed a and the molecular area Am. Compression speed a was about 30,40,50mm/min. LB layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film.The physicochemical properties of the LB films were examined by UV absorption spectrum, SEM and AFM. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 3~9. Also, we then examined of the MIM device by means of I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

Large Slow-Drift Motions of a Floating Body in Slightly Modulated Waves (해상(海上)에 계류(繫留)된 부유체(浮遊體)의 표류운동(漂流運動) 해석(解析))

  • Dong-J.,Kim;Hang-S.,Choi
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.4
    • /
    • pp.3-14
    • /
    • 1990
  • For a moored body on the sea surface, incident waves with narrow-banded spectra excite the body oscillations of short and long periods. Since the period of slow oscillations can be as long as the natural period of the moored body in horizontal modes, resonance can occur and resulting large motions may cause significant strains in mooring cables. By using the perturbation method of multiple scales, the large slow motion can be analyzed without solving any second-order potentials explicitly. To the leading order, the flows associated with the fast and slow motions interact only parametrically and thus they can be studied separately. It is found that the slow motion strongly depends on the mooring stiffness. In particular, if the moring stiffness is considerably weak compared to the body inertia, the slow motion is highly amplified near resonance. It is also shown that the slow motion is associated with the generation of long waves.

  • PDF